File: XDP3002_E 01/2010/eVIII • 4
8
Q (l/min)
I (%)
Q (l/min)
I (%)
Q (l/min)
XDP.3.*.01.N
(8 l/min P
A/B)
XDP.3.*.01.N
(15 l/min P
A/B)
XDP.3.*.01.N
(25 l/min P
A/B)
XDP.3.C.01.N... XDP.3.C.03.N... XDP.3.C.01.P...
XDP.3.A.01.N... XDP.3.A.03.N... XDP.3.A.01.P...
XDP.3.*.01.N
(40 l/min P
A/B)
I (%)
Q (l/min)
I (%)
p = 10 bar
With
AM.3.H.3V.P1.08
(p »8 bar)
p = 5 bar
p = 10 bar
p = 10 bar
p = 5 bar
p = 10 bar
p = 5 bar
INPUT SIGNAL CURVES - FLOW RATE
ORDERING CODE
The open loop valves of series XDP... control the direction and the volume of the flow according
to the feeding current to the proportional solenoid. By using a valve body equipped with
increased passage channels it is possible to reach the highest capacity of its dimensions at a
parity of pressure drops, (40 l/min with p of 10 bar).
Each p variation on the valve leads to the variation of the capacity which has been set, anyway
the valve guarantees an high inner compensation grade and limits the adjustment capacity.
Performances shown in this catalogue are guaranteed only using 2 or 3 way modular
assembly hydrostats type AM.3.H. ... By using the valve with the base for capacity doubling
type BC.3.07 (see next page) a greater capacity cam be obtained.
XDP.3.A... / XDP.3.C ...
P
ROPORTIONAL DIRECTIONAL VALVES OPEN LOOP
XDP Open loop proportional
directional valve
3 CETOP 3/NG6
* A = Single solenoid
C = Double solenoid
** Type of spool (null position)
01 =
03 =
* Flow path control
(see hydraulic symbols table)
N = symmetrical
P = meter in (only with 01 spool)
* Flow rating
l/min (p 10 bar)
1 = 8 l/min
2 = 15 l/min
3 = 25 l/min
6 = 40 l/min
* Max. current to solenoid
E = 2.35 A
F = 1.76 A
G = 0.88 A
** 00 = No variant
P1 = Rotary emergency
P5 = Rotary emergency 180°
V1 = Viton
2 Serial No.
In order to reduced the un-
loading pressure for rated
flow version at 40 l/min we
advise to use the 3 way type
AM.5.H.3V... hydrostat.
XDP.3...
D15P PROPORTIONAL SOLENOIDS CH. VIII PAGE 5
REM.S.RA... CH. IX PAGE 4
REM.D.RA... CH. IX PAGE 7
SE.3.AN21.00... CH. IX PAGE 11
AM.3.H... CH. VIII PAGE 16
AM.5.H... CH. VIII PAGE 17
BC.3.07... CH. VII PAGE 12
Q (l/min)
P (bar)
1
2
POWER LIMITS TRANSMITTED
Curve 1
15 l/min
version
Curve 2
40 l/min
version
P
A/B
T or P
B/A
T
File: XDP3002_E 01/2010/eVIII • 5
8
OPERATING SPECIFICATIONS
Max. operating pressure ports P/A/B 350 bar
Max. pressure port T - for dynamic pressure see note (*) 250 bar
Nominal flow 8 / 15 / 25 / 40 l/min
Duty cycle Continuous 100% ED
Type of protection (depending on the connector used) IP 65
Flow rate gain See diagram
Power limits curves transmitted See diagram
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Ambient temperature -20°C ÷ 70°C
Max. contamination level from class 7 at 9 in accordance
with NAS 1638 with filter ß
10
75
Weight XDP.3.A... (single solenoid) 1,7 Kg
Weight XDP.3.C... (double solenoid) 2,9 Kg
Max. current 2.35A 1.76 A 0.88 A
Solenoid coil resistance 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 Ohm
Hysteresis P / A / B / T
with a pressure compensator AM.3.H.3V... 5 % <5% <8%
Response to step p = 5 bar (P/A)
0 ÷ 100% 32 ms 40 ms 85 ms
100% ÷ 0 33 ms 33 ms 33 ms
Frequency response -3db (Input signal 50% ±25% Vmax)
22Hz 22Hz 12Hz
(*) Pressure dynamic allowed for 2 millions of cycles
Operating specifications are valid for fluids with 46 mm
2
/s viscosity at 40°C, using the
specified ARON electronic control units. Performance data carried out using the
specified Aron power amplifier SE.3.AN... serie 1 - EUROCARD format - powered
to 24V.
XDP.3.A... / XDP.3.C ... PROPORTIONAL DIRECTIONAL VALVES OPEN LOOP
AMPLIFIER UNIT AND CONTROL
REM.S.RA.*.*. and REM.D.RA.*.*.
Electronic card control single and double pro-
portional solenoid valve.
SE.3.AN.21.00...
Electronic card format EUROCARD for con-
trol and double proportional solenoid valve
AM.3.H.2V.P1 / AM.3.H.3V.P1
and AM.5.H.3V.P1 (*)
Hydrostats 2 or 3 way
(*) for rated flow XDP3 version at 40 l/min only
XDP.3.A...
BC.3.07
Standard subplate
CONFIGURATION FORDOUBLEFLOWRATE
OVERALL DIMENSIONS
Support plane
specifications
Fixing screws UNI 5931 M5x25
(min. 8.8 material screws are recommended)
Tightening torque 4 ÷ 5 Nm / 0.4 ÷ 0.5 Kgm
P1 Rotary emergency
P5 Rotary emergency 180°
"D15P" PROPORTIONAL SOLENOIDS
Type of protection (in relation to connector used) IP 66
Duty cycle 100% ED
Insulation class wire H
Weight (coil) 0,354 Kg
Weight (solenoid) 0,608 Kg
ETD15P - 01/2002/e