8
TRANSDUCER ELECTRICAL CONNECTIONS
SOL_XDC - 01/2000/e
OPERATING SPECIFICATIONS OF VALVE WITH TRANSDUCER
Max. operating pressure ports P/A/B 350 bar
Dynamic pressure port T 210 bar
Static pressure port T 210 bar
Nominal flow 8 / 15 / 25 / 40 l/min
Duty cycle Continuous 100% ED
Type of protection (depending on the connectors used) IP 65
Performance curves See diagrams
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Ambient temperature -20°C ÷ 70°C
Max. contamination level class 7 to 9 in accordance to NAS 1638 with filter ß
10
≥75
Weight XDC.3.A... (single solenoid) 1,94 Kg
Weight XDC.3.C... (double solenoid) 2,55 Kg
Max. current 1.76 A
Solenoid coil resistance at 20°C (68°F) 4.55 Ω
Solenoid coil resistance when hot 7.34 Ω
Hysteresis P/A/B/T with pressure compensator AM.3.H.3V... <1%
Transient function with stepped electrical input signals ∆p = 5 bar (P/A)
0 ÷ 100% 65 ms
100% ÷ 0 75 ms
Repeatibility <0,5%
Frequency response -3db (Input signal ±25% Vmax) 10 Hz
Insulation class wire H
Weight of solenoid 0,6 Kg
Operating specifications are valid for fluids with 46 mm
2
/s viscosity at 40°C, using the
SE3AN21RS... serie 3 ARON electronic control unit powered to 24V.
XDC.3... PROPORTIONAL DIRECTIONAL VALVES CLOSED LOOP POSITION CONTROL
AMPLIFIER UNIT AND CONTROL
SE.3.AN.21.RS...serie 3 - Electronic card
EUROCARD format for control of the propor-
tional valve equipped with transducer
AM.3.H.2V.P1 / AM.3.H.3V.P1
AM.5.H.3V.P1 (*)
Hydrostats 2 or 3 way
(*) for rated flow XDC3 version at 40 l/min ) only
POSITION TRANSDUCER SPECIFICATION
Electrical measuring system LVDT
Nominal stroke 6 mm
Electrical connection M12x1
Insulation
(depending on the connector used) IP65
Frequency response 500 Hz
Linearity tolerance ±1%
1 = Supply 18VDC ÷ 36VDC
3 = Mass
2 = Output 2V ÷ 10V
PROPORTIONAL
SOLENOID
OVERALL DIMENSIONS
Support plane
specifications
Fixing screws UNI 5931 M5x25
(min. 8.8 material screws are recommended)
Tightening torque 4 ÷ 5 Nm / 0.4 ÷ 0.5 Kgm
TRANSDUCER