File: QC32005_E 02/2009/eIII • 2
3
Q (l/min)
P (bar)
Q (l/min)
Q (l/min)
p (bar)
Q (l/min)
QC.3.2.**.*.R
QC.3.2.G.**.*.R
QC.3.2...
6
5
4
3
2
1
6
5
4
3
2
1
ORDERING CODE
QC.3.2... 2 WAY COMPENSATED
FLOW RATE REGULATORS
No. of turns of knobNo. of turns of knob
REGULATED FLOW RATE
1 TURN VERSION
REGULATED FLOW RATE
4 TURNS VERSION
FLOW RATE - INLET PRESSURE FREE FLOW THROUGH
CHECK VALVE
QC Compensated flow rate regulated
3 CETOP 3/NG6
2 2 way
G Anti-jump system with internal
check valve (omit if not required)
** Nominal flow rate ranges
1 Turn version 4 Turn version
Q1 = 1,5 l/min Q1 = 1,5 l/min
Q2 = 3 l/min Q2 = 4 l/min
Q3 = 9 l/min Q3 = 10 l/min
Q4 = 19 l/min Q4 = 21 l/min
Q5 = 24 l/min Q5 = 28 l/min
Q6 = 30 l/min Q6 = 35 l/min
K Version with lock
(omit if not required)
* 1 = 1 turn version
4 = 4 turns version
R With internal check valve
(omit if not required)
** 00 = No variant
V1 = Viton
5 Serial No.
HYDRAULIC SYMBOLS
DIAGRAMS
These QC.3.2... compensated flow
rate regulators are designed to control
and maintain a constant irrespective
of the pressure variations upstream
and downstream of the regulation
section. Their new cast construction
has made it possible to obtain a wider
flow rate range, taking the upper limit
to 35 l/min (4 turns version) while
maintaining unchanged the pressure
differential required to obtain good
pressure compensation.
All models are available with and with-
out reverse flow check valve, com-
plete with an "anti-jump" device on
request. This accessory has been
designed to eliminate the problem
which manifests itself as a "anti-jump"
in the controlled actuator due to the
instantaneous flow rate variation that
takes place under the form of a tran-
sient every time the flow is made to
pass through the regulator.
Max. operating pressure 320 bar
Opening pressure (with bypass) 1 bar
Min. regulated flow rate (Q1 version) 0.03 ÷ 0.05 l/min
Nominal regulated flow rate
(1 turn version) 1,5 ÷ 30 l/min
Nominal regulated flow rate
(4 turns version) 1,5 ÷ 35 l/min
Difference in pressure (p) for vers. Q1 3 bar
Difference in pressure (p) Q2-Q3-Q4-Q5-Q6 8 bar
Hydraulic fluids Mineral oils DIN 51524
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level(*) class 10 in accordance
with NAS 1638 with filter ß
25
75
Dependency on temperature (Q1 vers.) 5%
Dependency on temperature (Q2 vers.) 3%
Dependency on temperature (Q3-Q4-Q5-Q6) 2%
Weight 1,5 Kg
(*) Max contamination level must be respect to obtain
the right function of the valve
QC.3.2...
OVERALL DIMENSIONS CH. III PAGE 4