File: TLFCDC3_E 01/2010/eXI • 9
11
SETTORE
MOBILE
The emergency control lever for solenoid valves by Aron, represents a
develop in terms of safety and flexibility among applied hydraulic components.
Thanks to his flexibility, the component was designed to be inserted between the valve
body and the spool, providing total interchangeability between the different types of solenoid
body valves manufactured by Aron. It is compatible with the standard CETOP 3 and stackable
valves with threaded connections –G3/8" or 9/16-18UNF (SAE 6). The component is available
for both directional control and proportional valves (for the last type of control please consult
our Technical Department)
As an emergency lever applied to solenoid valves, the control can be used as a safety
device in conformity with the industry standards , also playing an useful role in the event of
power cuts. The control can be used in agricultural and mobile fields; the manual action can
be used to carry out periodic maintenance work on mobile components of the vehicle , in
perfectly safe working conditions.
"LF" VARIANT - EMERGENCY CONTROL LEVER FOR
STACKABLE
VALVES
(CDC/CD3)
MOUNTING COMPATIBILITY
CODE VALVE DESCRIPTION COIL VOLTAGE
CDC.3... Stackable valve A09 27 W
CD.3... Stackable valve D15 30 W
Max operating pressure port T:
dynamic 160 bar
static 210 bar
Max operating pressure port P
for series connection configuration 160 bar
MOUNTING TYPE: C / F / H
SPOOLS TYPE: 01/02/03*/04/16/17/66
HYDRAULIC SIMBOL
* The spool 03 is allowed only on CD3. Not permitted with CDC3
OVERALL DIMENSION
CDC.3...
VERSION
CD.3...
VERSION
Support plane
specifications
File: FI3002_E 01/2010/eXI • 10
11
SETTORE
MOBILE
STUDS AND FIXING FEET FOR MOUNTING
Tighten the screws to a torque of 10 Nm
CDC3...
WITH A09 COIL
CD3... WITH D15 COIL
CX3... CXQ3... WITH D15P COIL
MOUNTING KIT, 4 RODS AND 8 STUD NUTS
CODE COMPOSITION LENGTH (mm)
V89B50012 no. 2 elements with FE.02 or FE and FU 1170
V89B50013 no. 3 elements with FE.02 or FE and FU 210
V89B50014 no. 4 elements with FE.02 or FE and FU 260
V89B50015 no. 5 elements with FE.02 or FE and FU 310
V89B50016 no. 6 elements with FE.02 or FE and FU 350
V89B50017 no. 7 elements with FE.02 or FE and FU 400
V89B50018 no. 8 elements with FE.02 or FE and FU 440
V89B50022 no. 2 elements with FE.10 and FU 180
V89B50023 no. 3 elements with FE.10 and FU 220
V89B50024 no. 4 elements with FE.10 and FU 270
V89B50025 no. 5 elements with FE.10 and FU 310
V89B50026 no. 6 elements with FE.10 and FU 360
V89B50027 no. 7 elements with FE.10 and FU 410
V89B50028 no. 8 elements with FE.10 and FU 450
V89B50032 no. 2 elements with FE10P and FU 190
V89B50033 no. 3 elements with FE10P and FU 240
V89B50034 no. 4 elements with FE10P and FU 285
V89B50035 no. 5 elements with FE10P and FU 330
V89B50036 no. 6 elements with FE10P and FU 380
V89B50037 no. 7 elements with FE10P and FU 430
V89B50038 no. 8 elements with FE10P and FU 470
FIXING FEET KIT
CODE COMPOSITION
V89980000 all n. 2 fixing feet
File: CDC3002_E 01/2010/eXI • 2
11
SETTORE
MOBILE
L 12V
M 24V
N 48V*
P 110V*
Z 102V*
X 205V*
W Without DC coils
* Special voltage
115Vac/50Hz
120Vac/60Hz
with rectifier
230Vac/50Hz
240Vac/60Hz
with rectifier
CDC Directional control
stackable valve
3 Size
* Body type (tab. 1)
E Electrical operator
** Spool (tab.2)
For series connection
use spool 04 only
* Mounting (tab.3)
* Voltage (tab.4)
** Variants (tab.5)
2 Serial No.
TAB.2 - STANDARD SPOOLS
TWO SOLENOIDS,SPRING CENTRED "C" MOUNTING
Spool Covering Transient position
type
01 +
02 -
03 +
04* -
ONE SOLENOID, SIDE A "E" MOUNTING
Spool Covering Transient position
type
01 +
02 -
03 +
04* -
15 -
16 +
ONE SOLENOID, SIDE B "F" MOUNTING
Spool Covering Transient position
type
01 +
02 -
03 +
04* -
15 -
16 +
Max. pressure ports P/A/B/T 250 bar
Max flow 30 l/min
Max excitation frequency 3 Hz
Duty cycle 100% ED
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max contamination level class 10 in accordance
with NAS 1638 with filter ß
25
75
Weight with one DC solenoid 1,25 Kg
Weight with two DC solenoids 1,5 Kg
ORDERING CODE
For series connection
configuration, a special
individual stackable valve
CDC.3.*.E.04.**.3T.2 (A B or G
parallel body type only, with
spool 04 type, 3T variant) must
always be used as first element.
For other individual stackable valve
must use body D E or H connector
series type with spool 04 only.
CDC.3.*.E...
D
IRECTIONAL CONTROL STACKABLE VALVE
* SPOOL WITH PRICE INCREASING
CDC.3.*.E...
INDIVIDUAL VALVE CH. XI PAGE 3
STACKABLE VALVES CH. XI PAGE 4
"A09" DC COILS CH. XI PAGE 8
"LF" VARIANTS CH. XI PAGE 9
SCREWS AND STUDS CH. XI PAGE 10
STANDARDCONNECTORS CH. XI PAGE 25
TAB.3 MOUNTING
STANDARD
C
E
F
S
PECIALS (WITH PRICE INCREASING)
G
H
Directional control stackable valve body is available in two different sizes:
G3/8" or 9/16-18UNF (SAE 6).
The operation of the directional valve is electrical. The centring is achieved by means of
calibrated length springs which immediately reposition the spool in the neutral position when
the electrical signal is shut off. To improve the valve performance, different springs are used
for each spool.
The solenoids, constructed with a protection class of IP65 in accordance with BS 5490
standards, are available in direct current form and different voltage. The electrical controls are
equipped with an emergency manual control inserted in the tube.
The electrical supply connectors meet DIN 43650 ISO 4400 standards. On request, could be
available the following coil connec-
tion variants: AMP Junior connec-
tions; flying leads connections, with
or without integrated diode; Deutsch
connections with bidirectional inte-
grated diode.
The body valve is white zinc plated.
TAB.4 - A09 - DC VOLTAGE
The AMP Junior coil and with the flying
leads (with or without diode) coils are avail-
able in 12V or 24V DC voltage only.
• The Deutsch coil with bidirectional diode
is available in 12V DC voltage only.
(*) P2 and R5 Emergency tightening torque
max. 9 Nm / 0.6 ÷ 0.9 Kgm with CH n. 22
(**) It's suggest to order the variant without connectors. The
connectors must be order separately. See Ch. XI Page 25
TAB.1 - BODY TYPE
A Ports G3/8" parallel
B Ports 9/16 - 18UNF parallel
D* Ports G3/8" series
E* Ports 9/16 - 18UNF series
G Attachment style, parallel
presetting for modular valves
H* Attachment style, series
presetting for modular valves
L Ports G3/8" parallel - LS vers.
M Attachment style, parallel-LS vers.
presetting for modular valves
(*) For series connection configuration see note below
ordering code
TAB.5 - VARIANTS (**)
S1 No variant 00
SV Viton V1
ES Emergency button E1
P2(*) Rotary emergency button P1
R5(*)Rotary emergency button 180° P5
PT First elem. for series connec. PT
- Pilot light X1
- Rectifier R1
LF Emergency control lever LE
LR Emergency control lever 180° LG
- Pilot light + Rectifier XR
FL coils with flying leads (250 mm) FL
LD coils with flying leads (130 mm)
and integrated diode LD
AJ AMP Junior connection AJ
CX Deutsch connec. bidr.diode CX
Other variants relate to a special design
C
OD. VARIANT REPLACED CODE
File: CDC3002_E 01/2010/eXI • 3
11
SETTORE
MOBILE
P (bar)
Q (l/min)
1
2
3
4
129,5
N°4 fori
Ø
6,5
81,5
=
P
T
E
O-Ring 2-008
Only for LS versions
p (bar)
Q (l/min)
1
2
3
4
5
6
7
8
9
10
CDC.3.*.E... DIRECTIONAL CONTROL STACKABLE VALVE
OVERALL DIMENSIONS
E = Manual override
PRESSURE DROPS
DIRECTIONAL CONTROL STACKABLE VALVE
The diagram at the side shows
the pressure drop curves for
spools during normal usage.
The fluid used is a mineral oil with
a viscosity of 46 mm
2
/s at 40 C°;
the tests have been carried out at
a fluid temperature of 40 C°.
LIMITS OF USE (MOUNTING C-E-F)
The tests have been carried out with solenoids at operating temperature
and a voltage 10% less than rated voltage with a fluid temperature of 50
C°. The fluid used was a mineral oil with a viscosity of 46 mm
2
/s at 40
degrees C. The values in the diagram refer to tests carried out with the
oil flow in two directions simultaneously (e.g. from P to A and at the same
time B to T).
In the cases where valves 4/2 and 4/3 are used with the flow in one
direction only, the limits of use could have variations which may
even be negative (See curve No 4 and Spool No 16 used as 2 or 3
ways). The tests were carried out with a counter-pressure of 2 bar
at T port.
Spool
type
curve
01 1
02 1
03 3
04 2
15-16 1(4*)
(p*) Parallel connections
(s*) Series connections
Spool
Connections
type
P A P B A T B T P T P/ T passing
01 4 4 4 4 / 9
02 (p*) 7 7 6 6 7 9
02 (s*) 7 7 6 6 8 /
03 4 4 6 6 / 9
04 (p*) 2 2 1 1 5 9
04 (s*) 2 2 1 1 3 /
15-16 F 6 6 5 10 / 9
15-16 E 6 6 10 5 / 9
Curve No.
(4*) = 15 and 16 spools used as 2 or 3 way, follow the curve n°4
Fittings, max. tightening torque 60 Nm
(*)
File: CDC3002_E 01/2010/eXI • 4
11
SETTORE
MOBILE
69
95,5
C
D
10
7
32
46
Ch./Hex. 10
STACKABLE DIRECTIONAL CONTROL VALVES
OVERALL DIMENSIONS
HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION
SERIES CONNECTION
PARALLEL CONNECTION
FE02-FE INLET MODULE FE 10 INLET MODULE
LENGTH LENGTH
NO. ELEMENTS
C
(mm)
D C
(mm)
D
2 192 180 202 190
3 238 226 248 236
4 284 272 294 282
5 330 318 340 328
6 376 364 386 374
For series connection configuration, a special individual valve
bank section (CDC.3.*.E.04.**.3T.2) must always be used as first
element (see ordering code)
Special element
CDC.3.*.E.04.**.3T.2
Special closing plug
Tighten the screws to a torque of 10 Nm