File: AM7UP001_E 00/2006/eIV • 36
4
OVERALL DIMENSIONS
Support plane
specifications
ORDERING CODE
AM.7.UP...
MODULAR
PILOT
OPERATED CHECK VALVES
CETOP 7
Max. operating pressure 350 bar
Opening pressure 2 bar
Piloting ratio 1 : 11,7
Max. flow 250 l/min
Hydraulic fluids Mineral oils DIN 51524
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 80°C
Ambient temperature -20°C ÷ 50°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß
25
75
Weight 7,2 Kg
AM.7.UP type modular check valves
allow free flow in one direction by
lifting a seated poppet, while in the
opposite direction the fluid can return
by means of a small piston piloted by
the other line pressure (piloted side).
The cast valve body allows limited
pressure drops during the fluid flow
through the various P/A/B/T lines.
They are available on single A or B
lines, and on double A and B lines
(see hydraulic symbols).
HYDRAULIC SYMBOLS
AM Modular valve
7 CETOP 7/NG16
UP Piloted check valve
** Control on lines
A / B / AB
* Opening pressure
2 = 2 bar
** 00 = No variant
V1 = Viton
1 Serial No.
AM.7.UP...
PRESSURE DROPS
P-Q
Valve fixing:
n° 4 screws T.C.E.I. M10 - Tightening torque 40 Nm
n° 2 screws T.C.E.I. M6 - Tightening torque 8 Nm
The longer of the screws depends on the type of assembly used.
Fixing screws UNI 5931 with material specifications 12.9
Seals:
n° 4 pieces OR 2-118/90SH PARKER (type 130)
n° 2 pieces OR 2-013/90SH PARKER (type 2043)
CETOP 7 (4.2-4-07) MOUNTING SURFACE
AM.7.UP.A
AM.7.UP.AB
AM.7.UP.B
p (bar)
Q (l/min)
1
2
3
4
1 =
A1 A
B1 B
2 =
AA1
BB1
3 =
A1A (AM.7.UP.B)
B1B (AM.7.UP.A)
4 =
P1 T
T 1 P
The fluid used is a mineral oil
with a viscosity of 46 mm
2
/s
at 40°C. The tests have been
carried out a fluid temperature
of 50°C.