File: AM5RGT001_E 01/2000/eIV • 34
4
p (bar)
Q (l/min)
This modular system produces a re-
generative circuit to increasing the
actuator (differential cylinder) exit
speed as shown in the diagram. In
particular, if a cylinder is used with a
2:1 ratio for operating surfaces, the
exit and re-entry speeds are the same.
ORDERING CODE
AM.5.RGT... MODULAR VALVES
FOR
REGENERATIVE CIRCUIT
CETOP 5
Max. operating pressure 350 bar
Max. flow at port A/B/P/T 70 l/min
Hydraulic fluids Mineral oils DIN 51524
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß
25
75
Weight 2,1 Kg
AM Modular valve
5 CETOP 5/NG10
RGT For regenerative circuit
A Size of check valves 1/2"BSP
1 Opening pressure
1 bar
** 00 = No variant
V1 = Viton
1 Serial No.
OVERALL DIMENSIONS
PRESSURE DROPS B
P
Support plane
specifications
HYDRAULIC SYMBOL
AM.5.RGT...
SCREWS AND STUDS CH. IV PAGE 35
File: TAMTR005_E 02/2000/eIV • 35
4
OVERALL DIMENSIONS
T
ABLE OF SCREW AND STUDS FOR MOUNTING CETOP 5/NG10
SCREWS CODE T.C.E.I L L1 COMPOSITION Qty.
Q26.07.4090 40 AD5... 4
Q26.07.4098 90 50 AD5... + 1 AM5... (ISO) 4
Q26.07.4301 100 60 AD5... + AM5VR 4
Q26.07.4302 110 70 AD5... + AM5VI 4
Q26.07.4099 120 80 AD5... + A88 4
STUDS CODE L L1 COMPOSITION SPECIAL NUTS CODE Qty.
M80.15.0004 150 100 AD5... + 2 AM5... (ISO) M27.05.0002 4
M80.15.0012 160 110 AD5... + AM5VR + AM5... (ISO) " 4
M80.15.0010 180 130 AD5... + A88... + AM5... (ISO) " 4
M80.15.0006 190 140 AD5... + A88... + AM5VR " 4
M80.15.0011 200 150 AD5... + 3 AM5... (ISO) " 4
Tighten M27.05.0002 to a torque of 8 Nm / 0.8 Kgm max.