File: AM3RGT001_E 01/2000/eIV • 20
4
∆p (bar)
Q (l/min)
This modular valve produces a regen-
erative system to increase the actua-
tor (differential cylinder) exit speed as
shown in the diagram.
In particular, if a cylinder is used with
a 2:1 ratio for the operating surfaces,
the exit and re-entry speeds are the
same.
AM.3.RGT... MODULAR VALVES FOR
REGENERATIVE
CIRCUIT
CETOP 3
Max. operating pressure 350 bar
Max. flow at port A/B/P/T 20 l/min
Hydraulic fluids Mineral oils DIN 51524
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß
25
≥75
Weight 1,7 Kg
AM Modular valve
3 CETOP 3/NG6
RGT For regenerative circuit
A Size of check valves 3/8"BSP
1 Opening pressure
1 bar
** 00 = No variant
V1 = Viton
1 Serial No.
PRESSURE DROPS A
→→
→→
→P
HYDRAULIC SYMBOLORDERING CODE
OVERALL DIMENSIONS
Support plane
specifications
AM.3.RGT...
SCREWS AND STUDS CH. IV PAGE 21