File: ADPH5001_E 03/2000/eI • 45
1
TAB.1 - ORIFICE ON LINE A/B
TAB.2 - PLUGS DISPOSAL
ORDERING CODE
ADPH.5... P
ILOTED VALVES CETOP 5/NG10
WITH CETOP 2/NG4 PILOT VALVE
These ADPH 5 valves are used primarily for controlling
the starting, stopping and direction of fluid flow. These
kind of distributors are composed by a main stage crossed
by the big flow from the pump (ADPH.5) and by a cetop 2
pilot directional solenoid valve (AD.2.E) available with
different mounting type .
When a short response time is requested, a special
version of solenoids with high dynamics is available with
the code AD.2.E.**.*.*FF.2 (Please, contact our Techni-
cal Aron Service).
ADPH
Piloted valve
The pilot valves AD.2.E...
must be ordered separately
5 CETOP 5/NG10
** Spool type (Table next page)
* Mounting (Table next page)
Standard orifice at port P: 1mm
* Orifice type on
Cetop 2 valves (Table 1)
0 = none
A / B / C / D / E / F / G = orifice
on line A
H / I / L / M / N / P / Q = orifice
on line B
* Piloting and draining type (Tab.2)
I = internal piloting
internal draining
E = internal piloting
external draining
X = external piloting
internal draining
(special body)
00 No variant
1 Serial No.
HYDRAULIC SYMBOL
On line A On line B ø(mm)
0 0 None
A H 0,5
B I 0,6
C L 0,7
D M 0,8
E N 0,9
F P 1
G Q 1,2
Internal piloting
Internal draining (I code)
Internal piloting
External draining (E code)
External piloting
Internal draining (X code)
ADPH.5...
STANDARD SPOOLS FOR ADPH.5 CH. I PAGE 46
TECH. SPECIFICATIONS ADPH5 CH. I PAGE 47
CETOP 2/NG04 CH. I PAGE 2
AD.2.E... CH. I PAGE 4
"A09" DC COILS CH. I PAGE 4
STANDARD CONNECTORS CH. I PAGE 19
File: ADPH5001_E 03/2000/eI • 46
1
p (bar)
1 2
3
4
5
6
7
8
Q (l/min)
The diagram at the side shows the pressure drop curves for spools
during normal usage. The used fluid is a mineral oil with a viscosity of
46 mm
2
/s at 40°C; the tests have been carried out at a fluid temperature
of 40°C. For flow rates higher than those in the diagram, the losses will
be those expressed by the following formula:
p1 = p x (Q1/Q)
2
where p will be the value for the losses for a specific flow rate Q which
can be obtained from the diagram, p1 will be the value of the losses
for the flow rate Q1 that is used.
PRESSURE DROPS
Spool Connections
type
P A P B A T B T P T
01 4 4 7 7
02 6 6 8 8 7
03 3 3 8 8
04 4 4 2 2 3
06 4 4 7 8
15 2 2 5 5
16 1 1 2 2
Curve No.
(* Spools with price increasing)
Pilot
Piloted
Scheme
Spool
Covering Transient position
type
01 +
02 -
03 -
04* -
06 +
15 -
16 +
HYDRAULIC SYMBOLS, SPOOLS AND MOUNTING
"A" MOUNTING
Pilot
Piloted
Scheme
Spool
Covering Transient position
type
01 +
02 -
03 -
04* -
06 +
"C" MOUNTING
"B" MOUNTING
ADPH.5...
PILOTED VALVES 5/NG10 WITH CETOP 2/NG4 PILOT VALVE
Pilot
Piloted
Scheme
Spool
Covering Transient position
type
01 +
02 -
03 -
04* -
06 +
15 -
16 +
File: ADPH5001_E 03/2000/eI • 47
1
OVERALL DIMENSIONS AND MOUNTING SURFACE
EXTERNAL BACK PRESSURE ON LINE P
(FOR SPOOL IN THE CENTRE POSITION)
ADPH.5...
PILOTED VALVES 5/NG10 WITH CETOP 2/NG4 PILOT VALVE
Max. operating pressure: ports P/A/B 250 bar
Max. operating pressure: port T (dynamic) 70 bar
Max. piloting pressure 250 bar
Min. piloting pressure 10 bar
Max. flow 120 l/min
Switching times (*see note below) Energizing: 20 ms
De-energizing: 50 ms
Piloting oil volume for engagement 1 cm
3
Hydraulic fluid mineral oil DIN 51524
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß
25
75
Mounting plate
Weight ADPH5 without pilot valve 3,4 Kg
Weight ADPH5 with pilot valve with one solenoid 4,3 Kg
Weight ADPH5 with pilot valve with two solenoids 4,5 Kg
(*) All the tests have been carried out with AD.2.E pilot valve with variant FF,
mounting type C, spool 03, flow 100 l/min,pressure 160 bar, back pressure on
the T line of 2 bar and oil temperature 40°C.
PILOT SOLENOID CONTROL VALVE SPECIFICATIONS
Mounting surface
When the main spool connect P to T in the centre position,
the minimum pressure of 10 bar is needed to move the main
spool (see the “Specifications”); for this reason a check
valve on the P line (see the drawing above) is necessary.
1 Pilot solenoid valve
Cetop 2/NG4 type AD.2.E...FF variant
2 Calibrated springs
3 Piloted valve ADPH.5
Fixing screws UNI 5931 M6x40
with material specifications 12.9
Tightening torque 8 ÷ 10 N / 0,8 ÷ 1 Kgm