File: ADP5V001_E 07/2000/eI • 39
1
p (bar)
Q (l/min)
1 2
3
4
5
6
TAB.3 - VARIANTS
ADP.5.V...
WITH PROXIMITY
SENSOR
L.V.D.T. CETOP 5/NG10
VARIANTS CODE
No variant (connectors as in the drawing) 00
Pilot light X1
Rectifier R1
Rotary emergency button P1
Solenoid valve without connectors (coils) S1
Without proximity connector LVDT S3
Without coils and proximity connector S4
Cable gland "PG 11" C1
With solenoid chamber external
drainage (Y) Q5
Max. operating pressure: ports P/A/B 350 bar
Max. operating pressure: port T (*) 250 bar
Max. flow 120 l/min
Max. excitation frequency 3 Hz
Duty cycle 100% ED
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß
25
75
Type of protection
(in relation to connector used) IP 66
Weight 6,2 Kg
(*) Pressure dynamic allowed for 2 millions of cycles
The ARON NG10 directional control
valves are designed for subplate
mounting with an interface in
accordance with UNI ISO 4401 - 05
- 04 - 0 - 94 standard (ex CETOP
R 35 H 4.2-4-05).
The single solenoid directional
valves type ADP5V are used in
applications where the monitoring
of the position of the spool inside
the valve is requested to manage
the machine safety cycles in
according with the accident
prevention legislation. These
directional valves are equipped with
an horizontal positioned inductive sensor on the opposite side of the solenoid, which is capable
of providing the first movement of the valve when the passage of a minimum flow is allowed.
Integrated in safety systems, these valves intercept actuator movements that could be
dangerous for the operators and for the machine.
ORDERING CODE
ADP High performances
directional control valve
5 CETOP 5/NG10
V Directional valve with
single solenoid and
L.V.D.T. proximity sensor
*** Spool and mounting (table 1)
* Voltage (table 2)
** Variants (table 3)
1 Serial No.
registered mark for industrial
environment with reference to the
electromagnetic compatibility.
European norms:
- EN50082-2 general safety norm -
industrial environment
- EN 50081-1 emission general norm -
residential environment
PRESSURE DROPS
The diagram at the side shows the pressure drop
curves for spools during normal usage. The fluid
used is a mineral oil with a viscosity of 46 mm
2
/s at
40°C; the tests have been carried out at a fluid
temperature of 40°C. For higher flow rates than
those in the diagram, the losses will be those
expressed by the following formula:
p1 = p x (Q1/Q)
2
where p will be the value for the losses for a
specific flow rate Q which can be obtained from the
diagram, p1 will be the value of the losses for the
flow rate Q1 that is used.
Spool
Connections
type
P A P B A T B T P T
01 3 3 5 5
02 4 4 6 6 5
66 3 3 6 5
06 3 3 5 6
16 1 1 2 2
Curve No.
TAB1 - STANDARD SPOOL
ONE SOLENOID
Spool Covering Transient position
type
01E +
01F +
02E -
02F -
66E -
06F -
16E +
16F +
32E +
ADP.5.V...
"D19" DC SOLENOIDS CH. I PAGE 39
STANDARD CONNECTORS CH. I PAGE 19
L.V.D.T. CH. I PAGE 21
* Special voltage
Voltage codes are not stamped on the plate,
their are readable on the coils.
DC VOLTAGE
L 12V
M 24V
N 48V*
P 110V*
Z 102V*
X 205V*
W Without DC coils
and connectors
TAB.2 - DC VOLTAGE
• Possible mountings: E / F
• The solenoid is in DC voltage only
115Vac/50Hz
120Vac/60Hz
with rectifier
230Vac/50Hz
240Vac/60Hz
with rectifier
File: ADP5V001_E 07/2000/eI • 40
1
OVERALL DIMENSIONS
Fixing screws UNI 5931 M6x40
with material specifications 12.9
Tightening torque
8 ÷ 10 Nm / 0.8 ÷ 1 Kgm
E = Manual override
GSQ = Square section seal
Support plane
specifications
ADP.5.V...
WITH PROXIMITY SENSOR L.V.D.T. CETOP 5/NG10
"D19" DC SOLENOIDS
Type of protection (in relation to the connector used) IP 66
Number of cycle 18.000/h
Supply tolerance ±10%
Ambient temperature -54°C ÷ 60°C
Duty cycle 100% ED
Max static pressure 210 bar
Insulation class wire H
Weight 1,63 Kg
V
OLTAGE MAX WINDING TEMPERATURE RATED POWER RESISTANCE AT 20°C
(V) (AMBIENT TEMPERATURE 25°C) (W) (OHM) ±10%
12V 105°C 42 3.43
24V 105°C 42 13.71
48V* 105°C 42 55
102V* 105°C 42 248
110V* 105°C 42 288
205V* 105°C 42 1000
* Special voltage
ETD19 - 03/2000/e
P1 ROTARY EMERGENCY