File: ADH8001_E 05/2009/eI • 57
1
TAB.1 - PLUGS ARRANGEMENT FOR THE PILOT AND DRAIN LINES
ORDERING CODE
ADH.8...4/3
AND 4/2
PILOTED VALVES CETOP 8/NG25
ADH Piloted valve
(Pilot valves and any
modulating valves should be
ordered separately)
8 CETOP 8/NG25
* Mounting type (see next page)
** Spool type (see next page)
* Piloting and draining
I = X internal / Y internal
IE = X internal / Y external
EI = X external / Y internal
E = X external / Y external
(see Tab.1 at side)
R Check valve incorporated at port P
- setting 5 bar (Tab. 2 below)
Only for I, IE versions
(Omit if not required)
** 00 = No variant
LC = Main spool stroke limiter
TA = High pressure (•)
(Up to 420bar on P/A/B ports)
1 Serial No.
ADH.8...IE
X internal piloting
Y external draining
ADH.8...E
X external piloting
Y external draining
ADH.8...I
X internal piloting
Y internal draining
ADH.8...EI
X external piloting
Y internal draining
Plugs type used: M6x6 both for pilot and drain
• Mounting surface in accordance with UNI ISO 4401 - 08 - 07 - 0 - 94 standard (ex CETOP
R 35 H 4.2-4-08).
• Pilot operated spool, solenoid controller.
• Stroke control of main spool.
• Presetting for pressure reducing valve mounting.
• Presetting for single-acting throttle valve mounting.
Type ADH.8 distributors are intended for interrupting, inserting and diverting a hydraulics
system flow.
Normally these distributors are composed of a main stage, crossed by circuit main flow, and
of a pilot stage available in several versions.
Various types of controls are available, used either individually or in combination for, among
other functions, stroke limitation and main spool movement speed control, in order to optimize
the hydraulic system operation where this type of valve is employed.
In those cases where normally to drain spools are used, it is necessary to remember that the
minimum changeover pressure due to the opposing springs is equal to approximately 5 bar
(see the operating features table next pages) and it is consequently necessary to specify when
ordering the check valve incorporated in the P line, if required (as shown below).
ADH.8...
STANDARD SPOOLS FOR ADH.8 CH. I PAGE 58
TECH. SPECIFICATIONS ADH.8... CH. I PAGE 59
SUBPLATES BSH.7... CH. I PAGE 60
CETOP 3/NG06 CH. I PAGE 8
STANDARD SPOOLS FOR AD.3.E CH. I PAGE 10
AD.3.E... CH. I PAGE 11
"D15" DC COILS CH. I PAGE 18
"K12" AC SOLENOIDS CH. I PAGE 18
STANDARD CONNECTORS CH. I PAGE 19
(•) For heavy applications, eg. concrete pumps
TAB. 2 - INTERNAL CHECK ON P
• For the spools 02-04-14-28 the piloting is
normally external; the internal piloting is
possible with the internal check valve (R).