File: ADH7002_E 03/2005/eI • 52
1
TAB.1 - PLUGS ARRANGEMENT FOR THE PILOT AND DRAIN LINES
ORDERING CODE
ADH Piloted valve - Pilot valves and
any modulating valves should be
ordered separately
7 CETOP 7/NG16
* Mounting type (see next page)
** Spool type (see next page)
* Piloting and draining
I = X internal / Y internal
IE = X internal / Y external
EI = X external / Y internal
E = X external / Y external
(see Tab.1 at side)
R Check valve incorporated at port P
(Tab. 2) Only for I and IE versions
(omit if not required)
** 00 = No variant
LC = Main spool stroke limiter
2 Serial No.
ADH.7... 4/3 AND 4/2
PILOTED VALVES CETOP 7/NG16
Type ADH.7 distributors are intended for interrupting, inserting and diverting a hydraulic
system flow. Normally these distributors are composed of a main stage, crossed by the circuit
main flow, and of a pilot stage available in several versions.
Various types of controls are available, used either individually or in combination for, among
other functions, stroke limitation and main spool movement speed control, in order to optimize
the hydraulic system operation where this type of valve is employed.
In those cases where normally to drain spools are used, it is necessary to remember that the
minimum changeover pressure due to the opposing springs is equal to approximately 5 bar
(see the operating features table next pages) and it is consequently necessary to specify when
ordering the check valve incorporated in the P line, if required (as shown below).
• Mounting surface in accordance with UNI ISO 4401 - 07 - 06 - 0 - 94 standard (ex CETOP
R 35 H 4.2-4-07).
• Pilot operated spool, solenoid controller.
• Stroke control of main spool.
• Presetting for pressure reducing valve mounting.
• Presetting for single-acting throttle valve mounting.
ADH.7...
STANDARD SPOOLS FOR ADH.7 CH. I PAGE 53
TECH. SPECIFICATIONS ADH.7... CH. I PAGE 54
SUBPLATES BSH.7... CH. I PAGE 55/56
CETOP 3/NG06 CH. I PAGE 8
STANDARD SPOOLS FOR AD.3.E CH. I PAGE 10
AD.3.E... CH. I PAGE 11
ADC.3... CH. I PAGE 5
"A09" DC COILS CH. I PAGE 7
"D15" DC COILS CH. I PAGE 18
"K12" AC SOLENOIDS CH. I PAGE 18
STANDARD CONNECTORS CH. I PAGE 19
ADH.7...I
X internal piloting
Y internal draining
ADH.7...IE
X internal piloting
Y external draining
ADH.7...EI
X external piloting
Y internal draining
ADH.7...E
X external piloting
Y external draining
Plugs type used: M5x5 both for pilot and drain.
Note: standard M6x6 orifice Ø1,5 insert in the P port (Z)
TAB. 2 - INTERNAL CHECK ON P
• For the spools 02-04-14-28 the piloting
is normally external; the internal piloting
is possible only with the internal check
valve (R).
ADH7*.**.*.R.**.2 VERSION