File: AD5I001_E 03/2000/eI • 42
1
Q (l/min)
B
T
P
B
P
A
A
T
p (bar)
AD.5.I... AUTOMATIC RECIPROCATING
VALVES
CETOP 5
Max. operating pressure port P 320 bar
Max. flow 100 l/min
Minimum permitted flow 10 l/min
Fluid viscosity 32 ÷ 60 mm
2
/s
Fluid temperature -20°C ÷ 60°C
Max. contamination level(*) class 10 in accordance
with NAS 1638 with filter ß
25
75
Positioner activating force 190 N
(measured with 1 bar on the T line)
Weight of version without positioner 3,4 Kg
Weight of version with positioner 3,6 Kg
(*) Max contamination level must be respect to obtain
the right function of the valve
GSQ = square section seal
ORDERING CODE
AD Directional control
5 CETOP 5/NG10
I Automatic reciprocating valve
at null flow
P Version with positioner to adjust the
pressure relief valve of the system
** 00 = No variant
V1 = Viton
2T = Variant for
regenerative
system
1 Serial No.
AD.5.I.P.2T.1 FOR REGENERATIVE SYSTEM
PRESSURE DROPS
Version AD.5.I.P.2T.1 integrated in a regenerative circuit for
compactors with roll on-off mobile system, solution useful for all
applications where to connect microswitch of proximity is not
possible. For any information about our regenerative manifold
Aron please contact our technical department. For special subplate
BS.5.RIA see Chapter X "Systems", next pages.
Fixing screws UNI 5931 M6x40
with material specifications min. 8.8
Tightening torque 5 Nm / 0.5 Kgm
Support plane
specifications
The operating principle of this type of
inverter valve, with interface UNI ISO
4401 - 05 - 04 - 0 - 94 standard (ex
CETOP R 35 H 4.2-4-05), is based on
the pressure unbalanced created in
its interior as a consequence of the
fluid flow rate. On starting the system
this valve assumes always a prefer-
ential position P B e A T.
When a pressure is applied to the
cylinder which exceeds the system
maximum flow rate valve calibration
value (e.g. end stroke actuator), a
hydraulic unbalanced is generated ca-
pable of changing over the valve and
inverting the cylinder direction of the
movement.
Tests carried out with mineral oil a
temperature of 40°C with a vis-
cosity of 46 mm
2
/s.
AD.5.I...