HD 049 · HD 069
HD 172 · HD 319
HD 419 · HD 619
·
Operating pressure up to 9137 psi
·
Nominal flow rate up to 118.9 gpm
High Pressure Filter Kits
40.95-5us
8700
7250
5800
Description
Application
In the high pressure circuits of hydraulic systems.
Performance features
Protection
against wear: By means of filter elements that, in full-flow filtration,
meet even the highest demands regarding cleanliness
classes.
Protection against
malfunction: Through installation near to the control valves or other
expensive components. The specific determined flow
rate guarantees a closed by-pass valve even
at ν 930 SUS (cold start condition).
Filter elements
Flow direction from outside to center. The star-shaped pleating of the filter
material results in:
• largeltersurfaces
• lowpressuredrop
• highdirt-holdingcapacities
• longservicelife
Filter maintenance
By using a clogging indicator the correct moment for maintenance is stated
and guarantees the optimum utilization of the filter life.
Materials
Filter bowl: Cold extruded steel
Coating: Powder paint
Seals: NBR (FKM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer microfiber web
Accessories
To monitor the clogging, screw-in (see section Dimensions) or
flange-mounted differential pressure switches are available.
Flange-mounted clogging indicators optionally with one or two switching
points resp. temperature suppression – Dimensions and technical data
see catalog sheet 60.30.
Operating pressure
0 ... 5800 psi, min. 2 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 9137 psi, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Nominal flow rate
Up to 118.9 gpm (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on the
following features:
• closedby-passvalveatν 930 SUS
• elementservicelife>1,000operatinghoursatanaverageuid
contamination of 0.27 g per gpm flow volume
• owvelocityintheconnectionlines:
up to 3626 psi 26.3 ft/s
>3626psi 39.4 ft/s
Filter fineness
5 µm(c) ... 16 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20).
Temperature range
- 22 °F ... + 212 °F (temporary - 40 °F ... + 248 °F)
Viscosity at nominal flow rate
at operating temperature: ν < 280 SUS
• asstartingviscosity ν
max
= 5560 SUS
• atinitialoperation: Therecommendedstartingviscositycanbe
read from the diagram D (pressure drop as
a function of the kinematic viscosity) as
follows: Find the 70 % p of the cracking
pressure of the by-pass valve on the vertical
axis. Draw a horizontal line so that it inter-
sects the p curve at a point. Read this point
on the horizontal axis for the viscosity.
Mounting position
Preferably vertical
Characteristics
Operating pressure p [psi]
Number of cycles n
p [psi]
p [psi]
ν [SUS]
Q [gpm]
p [psi]
p [psi]
ν [SUS]
Q [gpm]
p [psi]
p [psi]
ν [SUS]
Q [gpm]
D1
D2
D3
D4
p [psi]
Q [gpm]
ν [SUS]
p [psi]
HD049
1
2
4
5
6
0
3
14.5
7.3
21.8
0 5.3 10.6 15.8 21.1
26.4
31.7
3
1
4
2
5
6
29
58
87
116
145
174
0
930
1860
2790
3720
4650
HD069
1
2
4
5
6
0
3
14.5
7.3
21.8
0 5.3 10.6 15.8 21.1
26.4
31.7
3
3+4
1+2
1
4
2
5
6
29
58
87
116
145
174
0
930
1860
2790
3720
4650
0
HD172
1
0
6.6
13.2 19.8 33.0
26.4 39.6 46.2 52.8
2
4
5
6
3
14.5
7.3
21.8
1+3
4
6
2
5
29
58
87
116
145
174
0
930
1860
2790
3720
4650
HD319
1
2
4+5
6
0
3
0
26
53
79
105
132
14.5
7.3
21.8
1+3
2
5
4
6
29
58
87
116
145
174
0
930
1860
2790
3720
4650
Diagrams
p-curves for complete filters in Selection Chart, column 3
Pressure drop as a function of the flow volume
at ν = 162 SUS
Pressure drop as a function of the kinematic viscosity
at nominal flow
Pressure drop as a function of the flow volume
at ν = 162 SUS
Pressure drop as a function of the kinematic viscosity
at nominal flow
Pressure drop as a function of the flow volume
at ν = 162 SUS
Pressure drop as a function of the kinematic viscosity
at nominal flow
Pressure drop as a function of the flow volume
at ν = 162 SUS
Pressure drop as a function of the kinematic viscosity
at nominal flow
p [psi]
p [psi]
ν [SUS]
Q [gpm]
p [psi]
p [psi]
ν [SUS]
Q [gpm]
HD419
1
2
4+5
6
0
3
0
26
53
79
105
132
14.5
7.3
21.8
1+3
2
6
5
4
4
6
29
58
87
116
145
174
0
930
1860
2790
3720
4650
HD619
1
2
4+5
6
0
3
0
26
53
79
105
132
14.5
7.3
21.8
1
3+5
2
6
4
6
29
58
87
116
145
174
0
930
1860
2790
3720
4650
Diagrams
p-curves for complete filters in Selection Chart, column 3
Pressure drop as a function of the flow volume
at ν = 162 SUS
Pressure drop as a function of the kinematic viscosity
at nominal flow
Pressure drop as a function of the flow volume
at ν = 162 SUS
Pressure drop as a function of the kinematic viscosity
at nominal flow
D5
D6
Particle size x [µm] (for particles larger
than the given particle size x)
Filtration ratio β as a function of particle size x obtained by the
Multi-Pass-Test according to ISO 16889
Filter fineness curves in Selection Chart, column 4
Filtration ratio βforparticles>xµm
Efficiency [%]
Dx
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX 2 and paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For screen elements:
40S = screen material with mesh size 40 µm
60S = screen material with mesh size 60 µm
100S = screen material with mesh size 100 µm
Tolerances for mesh size according to DIN 4189
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Remarks:
•Filterversionswithoutby-passvalvesmustbeequippedwithacloggingindicator.
•Theltersetslistedinthischartarestandardlters.Ifmodicationsarerequired,wekindlyaskforyourrequest.
•CloggingindicatorstoscrewintothehydraulicblockseesectionDimensions.
•Fortheappropriate,ange-mountedcloggingindicatorsseecatalogsheet60.30.
* Element differential pressure stable up to 2320 psi, clogging indicator obligatory
HD 049-0213 7.1 D1/1 5EX2 5.2 - 5 V3.0510-13* 3.5 with screw-in bushing
HD 049-1503 7.9 D1/2 5EX2 4.9 102 1 V3.0510-03 3.3 -
HD 049-0216 12.4 D1/3 10EX2 5.1 - 5 V3.0510-16* 3.5 with screw-in bushing
HD 049-1506 13.2 D1/4 10EX2 6.8 102 1 V3.0510-06 3.3 -
HD 049-0218 17.2 D1/5 16EX2 5.6 - 5 V3.0510-18* 3.5 with screw-in bushing
HD 049-1508 19.8 D1/6 16EX2 6.9 102 1 V3.0510-08 3.3 -
HD 069-0213 13.2 D2/1 5EX2 8.7 - 5 V3.0520-13* 6.0 with screw-in bushing
HD 069-1503 15.9 D2/2 5EX2 10 102 1 V3.0520-03 5.7 -
HD 069-0216 21.1 D2/3 10EX2 11 - 5 V3.0520-16* 6.0 with screw-in bushing
HD 069-1506 22.5 D2/4 10EX2 14 102 1 V3.0520-06 5.7 -
HD 069-0218 26.4 D2/5 16EX2 12 - 5 V3.0520-18* 6.0 with screw-in bushing
HD 069-1508 27.7 D2/6 16EX2 15 102 1 V3.0520-08 5.7 -
HD 172-0213 21.1 D3/1 5EX2 16 - 5 V3.0623-13* 9.3 with screw-in bushing
HD 172-1503 27.7 D3/2 5EX2 17 102 1 V3.0623-03 8.6 -
HD 172-0226 34.3 D3/3 10EX2 18 - 5 V3.0623-26* 9.3 with screw-in bushing
HD 172-1506 39.6 D3/4 10EX2 23 102 1 V3.0623-06 8.6 -
HD 172-0218 43.6 D3/5 16EX2 19 - 5 V3.0623-18* 9.3 with screw-in bushing
HD 172-1508 47.6 D3/6 16EX2 25 102 1 V3.0623-08 8.6 -
HD 319-0213 29.1 D4/1 5EX2 20 - 5 V3.0817-13* 14.3 with screw-in bushing
HD 319-1503 30.4 D4/2 5EX2 24 102 1 V3.0817-03 13.2 -
HD 319-0216 51.5 D4/3 10EX2 24 - 5 V3.0817-16* 14.3 with screw-in bushing
HD 319-1506 66.0 D4/4 10EX2 33 102 1 V3.0817-06 13.2 -
HD 319-0218 71.3 D4/5 16EX2 25 - 5 V3.0817-18* 14.3 with screw-in bushing
HD 319-1508 87.2 D4/6 16EX2 33 102 1 V3.0817-08 13.2 -
HD 419-0213 40.9 D5/1 5EX2 29 - 5 V3.0823-13* 19.4 with screw-in bushing
HD 419-1503 50.2 D5/2 5EX2 33 102 1 V3.0823-03 18.1 -
HD 419-0216 70.0 D5/3 10EX2 33 - 5 V3.0823-16* 19.4 with screw-in bushing
HD 419-1506 87.2 D5/4 10EX2 47 102 1 V3.0823-06 18.1 -
HD 419-0218 87.2 D5/5 16EX2 35 - 5 V3.0823-18* 19.4 with screw-in bushing
HD 419-1508 100.4 D5/6 16EX2 48 102 1 V3.0823-08 18.1 -
HD 619-0213 58.1 D6/1 5EX2 41 - 5 V3.0833-13* 26.2 with screw-in bushing
HD 619-1503 74.0 D6/2 5EX2 49 102 1 V3.0833-03 24.5 -
HD 619-0216 87.2 D6/3 10EX2 49 - 5 V3.0833-16* 26.2 with screw-in bushing
HD 619-1506 105.7 D6/4 10EX2 67 102 1 V3.0833-06 24.5 -
HD 619-0218 118.9 D6/5 16EX2 51 - 5 V3.0833-18* 26.2 with screw-in bushing
HD 619-1508 118.9 D6/6 16EX2 68 102 1 V3.0833-08 24.5 -
1 2 3 4 5 6 7 8 9 10
Pressure drop see
diagram D/curve no.
gpm
psig
Nominal flow rate
Part No.
lbs
Symbol
Weight
Dirt-holding capacity
Cracking pressure of by-pass
Replacement filter element
Part No.
Filter fineness see diagr. Dx
Selection Chart
Remarks
B
C
A
I
F
E
D
K
G
B
C
F
E
D
L
H
B
C
F
E
D
K
G
B
C
F
E
D
L
H
B
C
B
C
G
E
F
D
K
F
L
H
B
Version with by-pass valve Version with screw-in bushing
HD 049 / 069
HD 172
HD 319 / 419 / 619
Dimensions
All measurements and tolerances required for machining are available on request.
AF
1 2 3 4 5 6 7 8
C
D
B
A
M
M
Measurements
Symbols
Terminal connection
Electrical clogging indicator
• Switchingvoltage: max.120VAC/175VDC
• Switchingcurrent: max.0.17AAC/0.25ADC
• Switchingpower: max.3.5VAAC/5WDC
• Typeofcontact: change-over
• Electricalprotection:IP65(withmountedand
secured socket)
Type A B C D E F G H I K L M
HD 049/069 5.24/8.96 2.36 M65 x 1.5* min. 0.51 1.40 0.89 M18 x 1.5* M18 x 1.5* 2.17 1.65 1.28 36*
HD 172 10.10 2.80 M75 x 1.5* min. 0.51 1.46 0.89 M30 x 1* M26 x 1.5* 2.76 1.87 1.61 27*
HD 319/419/619 8.58/11.10/15.08 4.02 M108 x 1.5* min. 0.55 1.77 1.28 M36 x 1* M36 x 1.5* 3.15 1.85 1.50 32*
DG 031.1700 M20 x 1.5* 3.66 1.73 Ø 0.39 Ø 0.10 1.80 0.81 0.65 - - - 30*
DG 032.1700 M20 x 1.5* 2.91 1.73 Ø 0.39 Ø 0.10 1.80 0.81 0.65 - - - 24*
Dimensions
Electrical differential pressure switch (change-over)
DG 031.1700
DG 032.1700
Optical differential pressure indicator
Response/Switching pressure
of the clogging indicators
72.5 psi
All measurements and tolerances required for machining are available on request.
A/F
* Dimensions in mm
5
3
2
1
7
6
4
Our engineers will be glad to advise you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.
Subject to change
40.95-5us · 0714
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS
filter elements undergo strict controls and tests according to the following
ISO standards:
ISO 2941 Verification of collapse/burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and
dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high
viscosity fluid
Before release into the series production the filter casing is tested for fati-
gue strength in our pressure pulse test rig. Various quality controls during
the production process guarantee the leakfree function and solidity of our
filters.
The functions of the complete filters as well as the outstanding features
of the filter elements assured by ARGO-HYTOS can only be guaranteed if
original ARGO-HYTOS spare parts are used.
Spare Parts
Quality Assurance
Pos. Designation Part No.
2 Back-ring HD 255.0102
3 O-ring 3.73 x 0.14 N007.0953
4 Filter bowl HD 319 (with pos. 2 and 3) HD 250.0701
4 Filter bowl HD 419 (with pos. 2 and 3) HD 451.0702
4 Filter bowl HD 619 (with pos. 2 and 3) HD 619.0701
5 Filter element see Chart / col. 8
6 By-pass valve HD 319.1510
7 Screw-in bushing HD 319.0212
Pos. Designation Part No.
1 Filter bowl HD 172 HD 171.0102
3 O-ring 2.48 x 0.14 N007.0634
5 Filter element see Chart / col. 8
6 By-pass valve HD 172.1500
7 Screw-in bushing HD 171.0205
HD 319 / HD 419 / HD 619
HD 172
HD 049 / HD 069
Pos. Designation Part No.
1 Filter bowl HD 049 HD 052.0102
1 Filter bowl HD 069 HD 072.0102
3 O-ring 2.11 x 0.14 N007.0543/1
5 Filter element see Chart / col. 8
6 By-pass valve HD 045.1510
7 Screw-in bushing HD 049.0503
We produce fluid power solutions
ARGO-HYTOS Inc. · P.O. Box 28 · Bowling Green, OH 43402 · USA
Phone: +1-419-353-6070 · Fax: +1-419-354-3496 · info.us@argo-hytos.com · www.argo-hytos.com