20.15-5us
FR 043
·
FR 072
·
Tank top mounting / In-line mounting
·
Hose connection up to ID ¾ inch
·
Nominal flow rate up to 18.5 gpm
Return Filters
Description
Characteristics
Ventilating Filter
Ventilation of the reservoir by an integral star-shape pleated filter element:
• removable (replace annually!)
• splash-proof
• neness 2 µm
Filter maintenance
By using a clogging indicator the correct moment for maintenance is stated
and guarantees the optimum utilization of the filter life.
Materials
Screw-on cap: Polyester, GF reinforced
Housing: Polyamide, CF reinforced, electrically conducting
Seals: NBR (FKM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer microbre web
Paper - cellulose web, impregnated with resin
Accessories
Electrical and optical clogging indicators are available on request.
Dimensions and technical data see catalog sheet 60.20.
Recommended hose clamps according to DIN 3017 Part 2 or equivalent for
hose OD 0.91 inch or 1.02 inch. For orders use ARGO-HYTOS Part No. 332
70 03 or 332 70 04.
Extension pipes on the bowl outlet are available in several lengths on request.
A self-assembly system for installation of extension pipes can be ordered.
For detailled information please see catalog sheet 20.390.
Application
In the return line circuits of hydraulic systems.
Performance features
Protection
against wear: By means of lter elements that, in full-ow ltration,
meet even the highest demands regarding cleanliness
classes.
Protection against
malfunction: By means of full-ow ltration in the system return, the
pumps above all are protected from dirt particles
remaining in the system after assembly, repairs, or which
are generated by wear or enter the system from outside.
Special features
Connection: Hose nipple
By-pass valve: The location close to the inlet port prevents dirt particles
retained by the lter element from entering into the clean
oil side.
Removable bowl: In case of maintenance the lter bowl is removed
together with the lter element - therefore dirt particles
are not ushed back into the tank.
Oil separator: Prevents oil splashing through the breather on mobile
application.
Extension pipe: A correct extension pipe length ensures oil outlet below
minimum oil level and prevents foaming.
Filter elements
Flow direction from outside to center. The star-shaped pleating of the lter
material results in:
large lter surfaces
low pressure drop
high dirt-holding capacities
long service life
Hydraulic fluids
Mineral oil and biodegradable uids
(HEES and HETG, see info-sheet 00.20).
With high lling conditions we recommend
an electrical conductivity >_ 500 pS/m at 68 °F.
Temperature range
- 22 °F ... + 176 °F (short intervals to + 212 °F)
Viscosity at nominal flow rate
at operating temperature: ν < 280 SUS
as starting viscosity: ν
max
= 5560 SUS
at initial operation: The recommended starting viscosity can be
read from the diagram D (pressure drop as
a function of the kinematic viscosity) as
follows: Find the 70 % p of the cracking
pressure of the by-pass valve on the vertical
axis. Draw a horizontal line so that it inter-
sects the p curve at a point. Read this point
on the horizontal axis for the viscosity.
Operating pressure
Max. 87 psi
Mounting position
Preferably vertical, outlet downwards
Nominal flow rate
Up to 18.5 gpm (see Selection Chart, column 2)
The nominal ow rates indicated by ARGO-HYTOS are based on the
following features:
closed by-pass valve at ν ≤ 930 SUS
element service life > 1,000 operating hours at an average
uid contamination of 0.27 g per gpm ow volume
ow velocity in the connection lines 14.8 ft/s
Connection
Hose nipple for hose up to ID ¾ inch.
Sizes see Selection Chart, column 6 (other connections on request).
Filter fineness
10 µm(c) ... 30 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
D1
D2
Dx
p [psi]
Q [gpm]
ν [SUS]
p [psi]p [bar]
ν [SUS]
Q [gpm]
p [psi]
0
2.9
5.8
8.7
11.6
14.5
1
2
0
3
2.6
4.0
6.6
9.3
1.3
5.3 7.9
10.6
FR043
0
14.5
29.0
43.5
58.0
72.5
1
3
2
930 1860
2790
3720
4650
0
2.9
5.8
8.7
11.6
14.5
1
2
0
3
5.3
7.9
13.2
18.5
2.6
10.6 15.8
21.1
FR072
0
14.5
29.0
43.5
58.0
72.5
1
3
2
930 1860
2790
3720
4650
Diagrams
p-curves for complete filters in Selection Chart, column 3
Filter fineness curves in Selection Chart, column 4
Particle size x [µm] (for particles larger
than the given particle size x)
Filtration ratio β as a function of particle size x obtained by the
Multi-Pass-Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX 2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the lter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For screen elements:
40S = screen material with mesh size 40 µm
60S = screen material with mesh size 60 µm
100S = screen material with mesh size 100 µm
Tolerances for mesh size according to DIN 4189
For ventilating filter elements:
2CL = 99.5 % lter efciency for particles of size 2 µm
For special applications, nenesses differing from these curves
are also available by using special composed lter material.
Filtration ratio β for particles > x µm
Efciency [%]
Pressure drop as a function of the kinematic viscosity
at nominal ow
Pressure drop as a function of the kinematic viscosity
at nominal ow
Pressure drop as a function of the flow volume
at ν = 162 SUS
(0 = casing empty)
Pressure drop as a function of the flow volume
at ν = 162 SUS
(0 = casing empty)
Selection Chart
As clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the lter length to various tank
depths. For ordering of accessories please use the below mentioned codes.
Order example: The filter FR 072-276 has to be supplied with an extension pipefor a mounting depth of 500 mm (resp. 19.69 inch).
Order description: FR 072-276 / EV 500
Part No. (Basic unit)
Mounted extension pipe (5 various lengths are available on request)
FR 043: EV 150 (5.90 inch), EV 200 (7.87 inch), EV 300 (11.81 inch), EV 400 (15.74 inch), EV 500 (19.69 inch)
FR 072: EV 250 (9.84 inch), EV 300 (11.81 inch), EV 400 (15.74 inch), EV 500 (19.69 inch), EV 600 (23.62 inch)
For the appropriate clogging indicator see catalog sheet 60.20.
When using pressure switches of series DG 813 sealing by means of an O-ring (order no. N007.0103, to be ordered separately) has to be guaranteed (tor-
que 4 Nm). When using manometers of series DG 200 variants with preformed sealing ring are to be used.
Remarks:
The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
Clogging indicators are optional and always delivered detached from the lter.
For fastening the lter the enclosed spring washers have to be used. Assembly torque 15
+5
Nm.
The lters listed in this chart are standard lters. Other designs available on request.
* Paper media supported with metal gauze
FR 043-256 6.6 D1/1 10EX2 6.1 ID
5
/
8
36 1 V3.0510-56 0.93 - -
FR 043-266 6.6 D1/1 10EX2 6.1 ID
5
/
8
36 2 V3.0510-56 0.93 L1.0403-51 (2CL) with oil separator
FR 043-168 9.2 D1/2 16EX2 6.1 ID
5
/
8
36 1 V3.0510-58 0.93 - -
FR 043-198 9.2 D1/2 16EX2 6.1 ID
5
/
8
36 2 V3.0510-58 0.93 L1.0403-51 (2CL) with oil separator
FR 043-281 7.9 D1/3 30P 4.0 ID
5
/
8
22 1 P3.0510-51 0.93 - -
FR 043-291 7.9 D1/3 30P 4.0 ID
5
/
8
22 2 P3.0510-51 0.93 L1.0403-51 (2CL) with oil separator
FR 072-266 13.2 D2/1 10EX2 13 ID ¾ 36 1 V3.0520-56 1.28 - -
FR 072-276 13.2 D2/1 10EX2 13 ID ¾ 36 2 V3.0520-56 1.28 L1.0403-51 (2CL) with oil separator
FR 072-188 18.5 D2/2 16EX2 13 ID ¾ 36 1 V3.0520-58 1.28 - -
FR 072-258 18.5 D2/2 16EX2 13 ID ¾ 36 2 V3.0520-58 1.28 L1.0403-51 (2CL) with oil separator
FR 072-281 13.2 D2/3 30P 6.6 ID ¾ 22 1 P3.0520-51* 1.28 - -
FR 072-291 13.2 D2/3 30P 6.6 ID ¾ 22 2 P3.0520-51* 1.28 L1.0403-51 (2CL) with oil separator
Pressure drop see
diagram D/curve no.
Remarks
Connection A
Nominal ow rate
Part No.
Symbol
Weight
Dirt-holding capacity
Cracking pressure of by-pass
Replacement lter element
Part No.
Filter neness see Diagr. Dx
Replacement ventilating lter
Part No.
(Filter neness, see diagrams)
1 2 3 4 5 6 7 8 9 10 11 12
gpm
g psi
lbs
inch
1 2
Type A B C
min./max.
D E F* G H I
1
I
2
K L M N O P Q
FR 043 0.69 2.95 2.36/2.40 2.01 1.09 0.43 0.87 2.56 6.89 4.33 3.35 3.46 4.25 2.56 0.43 2.32 80°
FR 072 0.81 2.95 2.36/2.40 2.01 1.09 0.43 0.87 2.56 10.63 4.33 7.17 3.46 4.25 2.56 0.43 2.32 80°
Type R
1
R
2
S U V mm W
FR 043 1.54 1.65 1.06 0.79 AF 27 1.57
FR 072 1.54 1.65 1.06 0.79 AF 27 1.57
Dimensions
Measurements
Symbols
* including the enclosed spring washers Ø10 mm (0.39 inch), DIN 137 shape B, corrugated
Connection
M12 x 1.5 for
clogging indicator
Dia hole
in reservoir
Required mounting surface
Max. oil level
under stationary
conditions when using
an oil separator
For dimension EV see selection chart
O-ring
Ventilating filter
Fineness 2 µm
(replaceable)
O-ring
(included in
basic equipment)
Oil separator
(included in
basic equipment)
1
2
3
4
5
6
8
9
7
Spare Parts
Pos. Designation Part No.
1 Screw-on cap FR 043.0201
2 O-ring 2.24 x 0.12 N007.0573
3 Compression spring N015.1606
4 Filter element s. Chart / col. 9
5 Filter bowl FR 043 * FR 043.0107
5 Filter bowl FR 072 * FR 072.0104
6 O-ring 1.97 x 0.08 N007.0501
7 Ventilating lter L1.0403-51
8 O-ring 2.72 x 0.16 N007.0704
9 Oil separator FR 043.0701
* Specify mounting depth (EV) in mm
The functions of the complete lters as well as the outstanding features
of the lter elements assured by ARGO-HYTOS can only be guaranteed if
original ARGO-HYTOS spare parts are used.
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS
lter elements undergo strict controls and tests according to the following
ISO standards:
ISO 2941 Verication of collapse/burst pressure rating
ISO 2942 Verication of fabrication integrity (Bubble Point Test)
ISO 2943 Verication of material compatibility with uids
ISO 3968 Evaluation of pressure drop versus ow characteristics
ISO 16889 Multi-Pass-Test (evaluation of lter neness and
dirt-holding capacity)
ISO 23181 Determination of resistance to ow fatigue using high
viscosity uid
Various quality controls during the production process guarantee the
leakfree function and solidity of our lters.
Our engineers will be glad to advise you in questions concerning lter application, selection as well as the cleanliness class of the ltered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specication sheet.
Subject to change
20.15-5us · 0714
Quality Assurance
We produce fluid power solutions
ARGO-HYTOS Inc. · P.O. Box 28 · Bowling Green, OH 43402 · USA
Phone: +1-419-353-6070 · Fax: +1-419-354-3496 · info.us@argo-hytos.com · www.argo-hytos.com