SMA 05
Q
max
17 l/min • p
max
250 bar • P
max
3 kW
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 1
Hydraulic Mini Power Pack
Technical Features
Standard Surface Treatment
Functional Description
AC and DC electro-hydraulic unit, easy-to-assemble, compact
Modularity offers many combinations of hydraulic circuits to suit various requirements
Main applications are fork lifts, lifting platforms, automotive lifts, cranes for small trucks,
snow plows, machine tools, food and textile industry
7 central block basic circuits options
Possibility of building up an additional circuit in the form of vertical or horizontal stacking
assembly
Rated power up to 3 kW with DC and AC
Single and triple-phase motors with power ratings of up to 3 kW
Tank capacities from 1.5 to 40 l with optional plastic tanks for cost saving
In the standard version, the aluminium basic block is without surface protection and steel
plate are zinc coated for 240 h protection acc. to ISO 9227
Compact mini hydraulic power packs are designed to fit small design envelopes and can be used
in lifting platforms, elevating tables, manipulators, small presses, machine tools and mobile
applications. Each power pack consists of an electric motor, a pump, a manifold and a tank.
The aluminum body forms the base of the power pack, on which all the main components, including
the hydraulic elements, are mounted. The function of the power packs is apparent from
the respective hydraulic circuit diagrams. The desired combination of particular components
and hydraulic elements can be defined by reference to the ordering code and the respective tables.
The additional hydraulic circuits can be built up in valve sizes 03 (RPEK), 04 (CETOP 02) and 06
(CETOP 03). The size 03 (RPEK) is in a form of sectional directional valves.
The mounting position of the power pack is horizontal or vertical - see Power Pack Dimensions
on pages 12 to 19. All ports have G1/4 internal threads (thread G3/8 to be agreed
with the manufacturer). With the standard model, the connecting ports A, B of the components
of the vertical stacking assembly are oriented to one side. Orientation of ports A, B to different sides
is to be discussed with the manufacturer. The basic combinations of electric motors and pumps
as well as their code designations are shown in tables 1 - 5.
Technical Data
Model Material used Surface treatment
Cylindrical steel tank sheet steel Komaxit RAL 7030
Square steel tank / cover sheet steel Komaxit RAL 7030
Cylindrical plastic tank BOREALIS ME 8131 (transparent) without surface treatment
Square plastic tank MOSTEN (transparent) without surface treatment
DC electric motor zinc-coated
AC electric motor RAL 7030
Other components acc. to manufacturer standard
For other surface treatment consult factory.
Example: steel tank version
Example: plastic tank version
Flow rate l/min see table 1, 2, 3, 4 and 5
Working pressure bar see table 1, 2, 3, 4 and 5
Max. operating pressure bar see table 1, 2, 3 and 4
Tank capacity l 1.5 - 40
Type of hydraulic pump gear pump, COUNTER-CLOCKWISE
Electrical Motor power ratings kW 0.12 - 3
Type of electric motor one- , three-phase and DC
Voltage of electric motor V 230 AC 230 / 400 AC 12 / 24 DC
Duty cycle S3 of electric motor % AC 100, DC see table
Frequency Hz AC 50
Protection degree of electric motor - insulation class AC IP 55-F, DC - see table (page 7)
Viscosity range mm
2
/s 20 ... 100
Fluid temperature range °C 0 ... +70
Fluid temperature range, short-time °C -20 ... +80
Ambient temperature max. °C +50
Thread of functional ports P, T, M, A, B G1/4 (G3/8 A, B on request)
Data Sheet Type
General information GI_0060 Products and operating conditions
R
0
M
0
01200
02400
20500
23050
0
3
4
6
0
1
2
3
4
5
0
A
B
C
D
E
F
0
F
K
0
S
R*
E*
M*
SMA 05- / . - - . - /
03
04
05
06
08
12
16
21
25
33
36
44
48
58
62
79
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 2
Ordering Code Single Pump
Code of the electric motor
(see tables 1-5)
Type of hydraulic circuit
(see table on pages 8)
Code of the tank
see pages 12, 14-18
Pump displacement in cm
3
Series GP0
0.32
0.40
0.50
0.63
Series GP1
0.8
1.2
1.6
2.1
2.5
3.3
3.6
4.4
4.8
5.8
6.2
7.9
Solenoid voltage
12 V DC
24 V DC
205 V DC
230 V AC 50 (60) Hz
Compact power pack
Nominal size of stacking
assembly elements
without
size 03
size 04
size 06
(see page 12)
Parallel plate
without
1 section
2 sections
3 sections
4 sections
5 sections
(see page 12)
Base platte
without
configuration A
configuration B
configuration C
configuration D
configuration E
configuration F
(see page 12)
Foot bracket
without foot bracket
low foot bracket
high foot bracket (only for tank codes 40-45)
Type of filter used
without filter
suction filter
return line filter without indication
return line filter with el. indication
return line filter with manometer
DC electric motor
with switch
one-phase electric motor
without starting module
with starting module
three-phase electric motor
*only for tank codes 56-60 and 30-32
0
S
R*
E*
M*
01200
02400
20500
23050
0
3
4
6
0
A
B
C
D
E
F
SMA05- / . 0 - G - . - /
0
1
2
3
4
5
0
F
K
4812
4816
4821
5812
5816
5821
6212
6216
6221
7912
7916
7921
Series GP1
4.8 + 1.2 cm
3
4.8 + 1.6 cm
3
4.8 + 2.1 cm
3
5.8 + 1.2 cm
3
5.8 + 1.6 cm
3
5.8 + 2.1 cm
3
6.2 + 1.2 cm
3
6.2 + 1.6 cm
3
6.2 + 2.1 cm
3
7.9 + 1.2 cm
3
7.9 + 1.6 cm
3
7.9 + 2.1 cm
3
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 3
Ordering Code Double Pump
Compact power pack
Pump displacement in cm
3
Solenoid voltage
12 V DC
24 V DC
205 V DC
230 V AC 50 (60) Hz
Nominal size of stacking
assembly elements
without stacking assembly
size 03
size 04
size 06
(see page 12)
Base platte
without stacking assembly
configuration A
configuration B
configuration C
configuration D
configuration E
configuration F
(see page 12)
Parallel plate
without stacking assembly
1 section
2 sections
3 sections
4 sections
5 sections
(see page 12)
Type of filter used
without filter
suction filter
return line filter without indication
return line filter with el. indication
return line filter with manometer
Foot bracket
without foot bracket
low foot bracket
high foot bracket (only for tank codes 40-45)
*only for tank codes 58-60 and 31-32
Code of the e-motor
1, 2, 3, 4, 5, 6, 7, 8
9, 10, 11, 12, 13,14, 15, 16, 17, 18
(see tables 3, 4)
Code of the tank
24, 31, 32, 44, 45, 55, 58, 59, 60, 69, 70
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 4
Tab. 1a Single Pumps AC Electric Motors - three-phase
*p
n
- nominal pressure = the highest working pressure allowed without time restriction
** p
max
- maximum allowable pressure of the pump for max. 20 sec. Motor overload max. 30 % for max. 20 sec.
In the case of rotation speed control keep the speed limits of the gear pump - see Gear Pumps catalog.
Code of the
three-phase motor
Code of the pump
03 GP0-... 04 GP0-... 05 GP0-... 06 GP0-... 08 GP1-... 12 GP1-... 16 GP1-... 21 GP1-...
p
max
** [bar] 240 250
400V n[1/min] P[kW] Q/p
n
* [l/min] / [bar]
9 1320 0.12 0.3 160 0.4 130 0.6 100 0.7 80 0.9 65 1.4 40 1.8 30
10 1320 0.18 0.3 220 0.4 190 0.6 150 0.7 120 0.9 95 1.4 60 1.8 45 2.5 35
11 1395 0.25 0.5 220 0.6 200 0.8 160 0.9 125 1.4 80 1.9 60 2.6 45
12 1400 0.37 0.8 200 0.9 180 1.4 120 1.9 90 2.6 70
13 1390 0.55 0.9 200 1.4 180 1.9 135 2.6 105
14 1400 0.75 1.4 200 1.9 180 2.6 140
15 1410 1.10 2.0 200 2.6 200
16 1410 1.50
17 1425 2.20
18 1425 3.00
27 2745 0.18 0.7 115 0.9 90 1.2 75 1.5 60 1.9 45 2.8 30
28 2740 0.25 0.7 160 0.9 130 1.2 100 1.5 80 1.9 65 2.8 40 3.8 30
29 2790 0.37 0.7 200 0.9 185 1.2 150 1.5 115 1.9 90 2.9 60 3.9 45 5.2 35
30 2820 0.55 1.2 200 1.5 175 1.9 135 2.9 90 3.9 65 5.3 50
31 2850 0.75 1.5 200 1.9 180 2.9 120 4.0 90 5.3 70
32 2850 1.10 1.9 200 2.9 175 4.0 130 5.3 100
33 2855 1.50 2.9 200 4.0 175 5.3 135
34 2855 2.20 4.0 200 5.3 200
35 2860 3.00
Code of the
three-phase motor
Code of the pump
25 GP1-... 33 GP1-... 36 GP1-... 44 GP1-... 48 GP1-... 58 GP1-... 62 GP1-... 79 GP1-...
p
max
** [bar] 250 200 160
400V n[1/min] P[kW] Q/p
n
* [l/min] / [bar]
9 1320 0.12
10 1320 0.18 3.0 30
11 1395 0.25 3.2 40 4.2 30 4.6 25
12 1400 0.37 3.2 55 4.2 45 4.6 40 5.6 35 6.1 30 7.4 25
13 1390 0.55 3.2 85 4.2 65 4.6 60 5.6 50 6.1 45 7.4 35 7.9 35 10.1 25
14 1400 0.75 3.2 115 4.3 90 4.6 80 5.7 65 6.2 60 7.5 50 8.0 45 10.2 35
15 1410 1.10 3.2 165 4.3 130 4.7 115 5.7 95 6.2 90 7.5 75 8.0 70 10.2 55
16 1410 1.50 3.2 200 4.3 175 4.7 160 5.7 130 6.2 120 7.5 100 8.0 95 10.2 75
17 1425 2.20 4.3 200 4.7 200 5.8 190 6.3 175 7.6 145 8.1 135 10.4 105
18 1425 3.00 6.3 200 7.6 195 8.1 180 10.4 145
27 2745 0.18
28 2740 0.25
29 2790 0.37 6.3 30
30 2820 0.55 6.4 40 8.6 30 9.3 30 114 25
31 2850 0.75 6.5 55 8.7 45 9.4 40 11.5 30 12.6 30 15.2 25
32 2850 1.10 6.5 80 8.7 65 9.4 60 11.5 45 12.6 45 15.2 35 16.3 35
33 2855 1.50 6.5 110 8.7 85 9.5 80 11.6 65 12.6 60 15.2 50 16.3 45
34 2855 2.20 6.5 165 8.7 125 9.5 115 11.6 95 12.6 85 15.2 70 16.3 65
35 2860 3.00 6.5 200 8.7 170 9.5 160 11.6 130 12.6 120 15.3 100 16.3 90
Tab. 1a Single Pumps AC Electric Motors - three-phase
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 5
Tab. 2a Single Pumps AC Electric Motors - single-phase
Code of the
single-phase motor
Code of the pump
03 GP0-... 04 GP0-... 05 GP0-... 06 GP0-... 08 GP1-... 12 GP1-... 16 GP1-... 21 GP1-...
p
max
** [bar] 240 250
230V n[1/min] P[kW] Q/p
n
* [l/min] / [bar]
1 1300 0.12 0.3 160 0.4 125 0.6 100 0.7 80 0.9 65 1.3 40 1.8 30
2 1350 0.18 0.4 220 0.4 185 0.6 150 0.7 115 0.9 90 1.4 60 1.9 45 2.5 35
3 1390 0.25 0.5 220 0.6 200 0.8 160 0.9 125 1.4 80 1.9 60 2.6 45
4 1410 0.37 0.8 200 0.9 180 1.4 120 1.9 90 2.6 70
5 1370 0.55 0.9 200 1.4 180 1.9 135 2.6 105
6 1410 0.75 1.5 200 2.0 180 2.6 140
7 1410 1.10 2.6 200
8 1410 1.50
19 2840 0.18 0.7 110 0.9 90 1.2 70 1.5 55 1.9 45 2.9 30
20 2840 0.25 0.7 155 0.9 125 1.2 100 1.5 80 1.9 60 2.9 40 3.9 30
21 2780 0.37 0.7 200 0.9 185 1.2 150 1.5 120 1.9 90 2.9 60 3.9 45 5.2 35
22 2820 0.55 1.2 200 1.5 175 1.9 135 2.9 90 3.9 65 5.3 50
23 2820 0.75 1.5 200 1.9 185 2.9 120 3.9 90 5.3 70
24 2845 1.10 1.9 200 2.9 175 4.0 130 5.3 100
25 2855 1.50 2.9 200 4.0 175 5.3 135
26 2810 2.20 5.3 200
Tab. 2b Single Pumps AC Electric Motors - single-phase
Code of the
single-phase motor
Code of the pump
25 GP1-... 33 GP1-... 36 GP1-... 44 GP1-... 48 GP1-... 58 GP1-... 62 GP1-... 79 GP1-...
p
max
** [bar] 250 200 160
230V n[1/min] P[kW] Q/p
n
* [l/min] / [bar]
1 1300 0.12
2 1350 0.18 3.1 30
3 1390 0.25 3.1 40 4.2 30 4.6 30
4 1410 0.37 3.1 55 4.2 45 4.6 40 5.6 30 6.1 30 7.4 25
5 1370 0.55 3.1 85 4.2 65 4.6 60 5.6 50 6.1 45 7.4 35 7.8 35 10.0 30
6 1410 0.75 3.2 115 4.3 85 4.7 80 5.7 65 6.2 60 7.5 50 8.0 45 10.2 35
7 1410 1.10 3.2 165 4.3 130 4.7 115 5.7 95 6.2 90 7.5 75 8.0 70 10.2 55
8 1410 1.50 3.2 200 4.3 175 4.7 160 5.7 130 6.2 120 7.5 100 8.0 95 10.2 75
19 2840 0.18
20 2840 0.25
21 2780 0.37 6.3 30
22 2820 0.55 6.4 40 8.6 30 9.3 30
23 2820 0.75 6.4 55 8.6 45 9.3 40 11.4 35 12.5 30 15.0 25
24 2845 1.10 6.5 85 8.6 65 9.4 60 11.5 50 12.5 45 15.1 35 16.2 35
25 2855 1.50 6.5 110 8.6 85 9.4 80 11.5 65 12.5 60 15.1 50 16.2 45
26 2810 2.20 6.5 165 8.6 130 9.4 120 11.5 95 12.5 90 15.1 75 16.1 70
Attention! Pay special attention to the start-up torque of single-phase motors. Use the start-up module during start-up under pressure.
*p
n
- nominal pressure = the highest working pressure allowed without time restriction
** p
max
- maximum allowable pressure of the pump for max. 20 sec. Motor overload max. 30 % for max. 20 sec.
In the case of rotation speed control keep the speed limits of the gear pump - see Gear Pumps catalog.
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 6
Tab. 3a Double Pumps AC Electric Motors 400 V - three-phase
Pump code P1+P2 4812 4816 4821 5812 5816 5821
P2 p
max
[bar] 250 for a short period only - max. 20 s
P1 p
max
[bar] 184 173 160 166 157 147
3 phase E-motor Q1 p1
n
Q1, Q2 [l/min] p1
n
, p2
n
[bar] P1 p
max
is limited due to torque of the pump shaft
code P[kW] Q2 p2
n
12 0.37
6.1 25 6.1 20
1.4 120 1.9 90
13 0.55
6.1 35 6.1 35 6.1 30 7.4 30
1.4 180 1.9 135 2.6 105 1.4 180
14 0.75
6.1 50 6.1 45 6.1 45 7.4 45 7.4 40 7.4 35
1.4 200 1.9 180 2.6 140 1.4 200 1.9 180 2.6 140
15 1.1
6.1 75 6.1 70 6.1 65 7.4 65 7.4 60 7.4 55
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
16 1.5
6.1 100 6.1 95 6.1 85 7.4 85 7.4 80 7.4 75
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
17 2.2
6.1 150 6.1 140 6.1 130 7.4 130 7.4 120 7.4 110
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
18 3
6.1 184 6.1 173 6.1 160 7.4 166 7.4 157 7.4 147
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
Tab. 3b Double Pumps AC Electric Motors 400 V - three-phase
Pump code P1+P2 6212 6216 6221 7912 7916 7921
P2 p
max
[bar] 250 for a short period only - max. 20 s
P1 p
max
[bar] 151 143 134 139 133 127
3 phase E-motor Q1 p1
n
Q1, Q2 [l/min] p1
n
, p2
n
[bar] P1 p
max
is limited due to torque of the pump shaft
code P[kW] Q2 p2
n
13 0.55
8 30 8 25
1.4 180 1.9 135
14 0.75
8 40 8 40 8 35 10.2 30
1.4 200 1.9 180 2.6 140 1.4 200
15 1.1
8 60 8 55 8 50 10.2 50 10.2 45 10.2 45
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
16 1.5
8 80 8 75 8 70 10.2 65 10.2 60 10.2 60
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
17 2.2
8 120 8 115 8 105 10.2 95 10.2 90 10.2 90
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
18 3
8 151 8 143 8 134 10.2 130 10.2 125 10.2 120
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
Tab. 4a Double Pumps AC Electric Motors 230 V - one-phase
Pump code P1+P2 4812 4816 4821 5812 5816 5821
P2 p
max
[bar] 250 for a short period only - max. 20 s
P1 p
max
[bar] 184 173 160 166 157 147
1 phase E-motor Q1 p1
n
Q1, Q2 [l/min] p1
n
, p2
n
[bar] P1 p
max
is limited due to torque of the pump shaft
code P[kW] Q2 p2
n
4 0.37
6.1 25 6.1 20
1.4 120 1.9 90
5 0.55
6.1 35 6.1 35 6.1 30 7.4 30
1.4 180 1.9 135 2.6 105 1.4 180
6 0.75
6.1 50 6.1 45 6.1 45 7.4 45 7.4 40 7.4 35
1.4 200 1.9 180 2.6 140 1.4 200 1.9 180 2.6 140
7 1.1
6.1 75 6.1 70 6.1 65 7.4 65 7.4 60 7.4 55
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
8 1.5
6.1 100 6.1 95 6.1 85 7.4 85 7.4 80 7.4 75
1.4 200 1.9 200 2.6 200 1.4 200 1.9 200 2.6 200
Tab. 4b Double Pumps AC Electric Motors 230 V - one-phase
Pump code P1+P2 6212 6216 6221 7912 7916 7921
P2 p
max
[bar] 250 for a short period only - max. 20 s
P1 p
max
[bar] 151 143 134 139 133 127
1 phase E-motor Q1 p1
n
Q1, Q2 [l/min] p1
n
, p2
n
[bar] P1 p
max
is limited due to torque of the pump shaft
code P[kW] Q2 p2
n
5 0.55
8 30 8 25
1,4 180 1,9 135
6 0.75
8 40 8 40 8 35 10,2 30
1,4 200 1,9 180 2,6 140 1,4 200
7 1.1
8 60 8 55 8 50 10,2 50 10,2 45 10,2 45
1,4 200 1,9 200 2,6 200 1,4 200 1,9 200 2,6 200
8 1.5
8 80 8 75 8 70 10,2 65 10,2 60 10,2 60
1,4 200 1,9 200 2,6 200 1,4 200 1,9 200 2,6 200
2
4
6
8
10
12
050 100 150 200
03
05
06
12
16
25
33
E-motor
12V 0,7kW
3
6
9
12
15
18
050 100 150 200
08
12
16
21
33
44
48
E-motor
24V 1,2kW
36
3
6
9
12
15
18
050 100 150 200
62
12
21
33
44
58
E-motor
12V 1,5kW
36
4
8
12
16
20
24
050 100 150 200
12
16
21
25
44
58
E-motor
24V 2kW
36
79
4
8
12
16
20
24
050 100 150 200
62
21
25
44
58
E-motor
24V 3kW
36
79
2
4
6
8
10
12
050 100 150 200
03
06
12
16
21
25
33
E-motor
24V 0,8kW
62
48
33
21
08
04
08
05
04
16
25
48
58
25
33
48
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 7
Characteristics pQ DC Electric Motors + Pumps
Code 63Code 52
Code 46 Code 51
Code 44
Code 45
Flow Q [l/min] Flow Q [l/min]Flow Q [l/min]
Flow Q [l/min] Flow Q [l/min]
Flow Q [l/min]
Pressure p [bar] Pressure p [bar]
Pressure p [bar] Pressure p [bar]
Pressure p [bar] Pressure p [bar]
Tab. 5 DC Electric Motors
12 V 24 V
kW
Protection degree -
insulation class
Code of the electric motor
45 / 0.7 IP 44
/ 44 0.8 IP 54
/ 46 1.2 IP 44
51 / 1.5 IP 54
/ 52 2.0 IP 54
/ 63 3.0 IP 20
Attention! The DC motors must be loaded. so as to reduce the revolutions! Do not run the motors without pressure loading!
In the case of rotation speed control keep the speed limits of the gear pump - see Gear Pumps catalog.
F
M
PT
Z
R
W
77
73.5 68
72
101
191
F
G
M
PT
W
Z
U
G
101 138.5
73.5 68
78.576
61
68
Y
X
M
73,5
68
Z
W
P
T
81,5
101
D
M
PT
Z
W
X
Y
DXY
M
P
M
X
Y
Z
L
EXY
M
P
T
M
Z
W
P
T
M
Z
W
Y
X
P
T
M
Z
W
M
ABCXY
Y
71
X
M
P
69
101
81,5
Z
L
68
E
P
T
P
T
W
M
Z
R
M
W
Z
U
X
X
PLUG in the Cavity X:
15960800 17250900
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 8
Basic Hydraulic Circuit Diagrams - Central Manifolds
72
175
102
5
70
58
8,5
5
30 max
1
2
1
2
100
4
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 9
Valves for Central Manifolds
*Exact position of the starting module or plug ... ref. page 18
X
Type of the seat valve Functional symbol
5
SD1M-A2/SL3
+ lever with micro switch
4
SD1M-A2/SL2
+ lever without micro switch
3
SD1M-A2/SL1
2
SD3E-A2/H2O2
1
SD3E-A2/H2L2
0*
17250900
Y
Type of the throttle valve Functional symbol
2
SF22A-A2/H**
**The size of the throttle valve corresponds regularly with
the flow rate Q of the pump used.
Other throttle valve size on request of the customer.
1
ST21A-A2/L20S
0
15960800 for X=0
0
17250900 for X≠0
M
Type Symbols
M*
Starting module
0*
Plug VSTI G1/4
Z W L R U
Pressure relief valve
directly operated
Check valve Load shuttle Hand pump Unloading valve
SR1A-A2/S (HA 5063) SC1F-A3 (HA 5016) VJ01-06/SG-01 SH1F-A3 (HA 5029) RC 3/4-16UNF SD2E-A3/H (HA 4041)
A, B, C, D, F G (HA 5004) E F (HA 2020) G
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 10
Table of Dimensions Dimensions of Electric Motors in millimeters
AC Electric Motor one-phase and three-phase
Code of EM
Power
[kW]
Voltage
[V]
Current [A]**
Speed
[1/min]**
B max.
[mm]
C max.
[mm]
D
[mm]
1 0.12 230 1.30 1300 248 139 120
2 0.18 230 1.70 1350 248 139 120
3 0.25 230 2.13 1390 261 151 141
4 0.37 230 2.82 1410 261 151 141
5 0.55 230 5.00 1370 305 157 159
6 0.75 230 6.00 1410 305 157 159
7 1.10 230 8.20 1410 314 165 174
8 1.50 230 10.00 1410 339 165 174
9 0.12 400 0.65 1320 248 101 120
10 0.18 400 0.78 1320 248 101 120
11 0.25 400 0.83 1395 261 105 140
12 0.37 400 1.14 1400 261 105 140
13 0.55 400 1.51 1390 305 127 159
14 0.75 400 1.98 1400 305 127 159
15 1.10 400 2.78 1410 314 139 174
16 1.50 400 3.61 1410 339 139 174
17 2.20 400 5.07 1425 390 148 196
18 3.00 400 6.66 1425 390 148 196
19 0.18 230 1.52 2840 248 139 120
20 0.25 230 1.90 2840 248 139 120
21 0.37 230 2.90 2780 261 151 141
22 0.55 230 4.10 2820 261 151 141
23 0.75 230 5.45 2820 305 157 159
24 1.10 230 8.00 2845 305 157 159
25 1.50 230 11.50 2855 314 165 174
26 2.20 230 14.80 2810 339 165 174
27 0.18 400 0.56 2745 248 101 120
28 0.25 400 0.73 2740 248 105 120
29 0.37 400 1.00 2790 261 105 140
30 0.55 400 1.40 2820 261 105 140
31 0.75 400 1.80 2850 305 127 159
32 1.10 400 2.54 2850 305 127 159
33 1.50 400 3.50 2855 314 139 174
34 2.20 400 4.95 2855 339 139 174
35 3.00 400 6.35 2860 390 148 196
DC Electric Motor
Code of EM
Power
[kW]
Voltage
[V]
Current
[A]**
Speed
[1/min]**
Load factor ** B [mm]* C [mm]* D [mm]* A [mm]
44 0.8 24 40 3300 S2 - 2.5 min S3 - 7 % ED 143 96 76 62
45 0.7 12 135 3300 S2 - 2.5 min S3 - 4 % ED 165 95 80 105
46 1.2 24 90 3000 S2 - 1.2 min S3 - 4 % ED 165 95 80 120
51 1.5 12 220 2600 S2 - 2 min S3 - 7.5 % ED 179 100 117 250
52 2.0 24 140 2600 S2 - 1.2 min S3 - 4.5 % ED 179 100 117 150
63 3.0 24 200 1700 S2 - 16 min S3 - 10 % ED 336 121 162 180
*Dimension B, C, D may differ, subject to supplier´s changes. **Valid for rated power values
Load factor
Duty S1 (min) – Intended for use under continuous duty cycle conditions (load factor S1) for various press-related applications and those which
involve dynamic strokes, with recommendation to consult the conditions of use with manufacturer.
Duty S2 (min) - short-time operation
The motor operates with constant load for a definite time until the motor reaches the maximum permissible temperature T max. It is followed by
an idle period long enough to reach equality between motor temperature and ambient temperature.
Duty S3 (% ED) - periodic operation
The operation of the motor is a continuous sequence of identical cycles, each compound from a load period and an idle period. During the load
period the motor can reach the maximum permissible temperature. S3 value shows, in percentage, the length of the load period with respect
to the total cycle-load period more idle period. The S3 curve quoted in the performance specifications is referred to a lenghts cycle of 10 minutes.
S
P
40
40
A
B
M
12
73,5 105
127
C
D
S
P
T
P
19 36 53 72
8,5
12 12
4 x M8
T P
20
41 41
L
4
150±0,2
175
87,5
12,5
175
12,5
46,5
150±0,2
82
6x 10,5
100
16,5
5,5
R3,5
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 11
Tank Dimensions Dimensions in millimeters
Power pack with cylindrical steel tank, one-phase and three-phase motors
- mounting position horizontal
Power pack foot bracket
Typ Dimensions L [mm]
F 37
K 62
Code of the tank Tank capacity [l] Working volume [l] A [mm]
10 (steel) 1.5 0.8 152
11 (steel) 2 1.1 252
12 (steel) 3 1.6 332
13 (steel) 4 2 412
Dimensions B, C, Ø D see Table of Dimensions - page 10
Tank Support
code 64-70 with holder
of power pack
configuration F
Connecting Block
Connecting Holder
Facing the pump
Facing the motor
2 x M10 / 20 Deep
Verze
A
04, 06D
n
Verze
B
D 04, 06
n
Verze C
D 04, 06
n
Verze D
D03
n
Verze F
D 04, 06
n
Verze E
D03
n
B A
B A
B A
B A
B A
P T
A
B A
B A
B A
B A
B A
P T
M
B
B
B
B
B
1 Base Plate
2 Parallel Plate
1
2
1
2
2
1
1
1
1 Base Plate
2 Parallel Plate
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 12
Valve Dimensions Dimensions in millimeters
Configuration A
Size 04, 06
Configuration B
Size 04, 06
Configuration C
Size 04, 06
Configuration D
Size 03
Configuration F
Size 04, 06
Configuration E
Size 03
Thread of the connecting ports A, B, P, T, M - G1/4 standard (A, B - G3/8 option)
Dimension E [mm] F [mm] G [mm]
Pressure
switch
Reducing
valves
Pressure relief
valves
Pilot operated check
valves cartridge
Check
valves
Flow
valves
Size 04 35 30 35 30 30 30 40 79
Size 06 43 45 40 40 31.4 40 50 92
Base Plates and Parallel Plates
1 Base Plate
21
183
40
A
11
A1
73,5 145
P
T
M
21
183
40
A
73,5
153
T P
M
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 13
Tank Dimensions Dimensions in millimeters
Power pack with cylindrical steel tank - mounting position horizontal
Power pack with cylindrical steel tank - mounting position vertical
Code of the tank Tank capacity [l] Working volume [l] A [mm] A1 [mm]
20 (steel) 6 3.7 269 40
22 (steel) 8 4.9 349 155
24 (steel) 10 6.1 429 195
Code of the tank Tank capacity [l] Working volume [l] A [mm]
51 (steel) 6 3.4 269
53 (steel) 8 5.4 349
55 (steel) 10 7.4 429
98,5
max. 177
12
87
(13)
159
305A40
110,5
25
49
100
7
12
111,5
135,5
137
223
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 14
Tank Dimensions Dimensions in millimeters
Power pack with cylindrical steel tank - mounting position horizontal
Code of the tank Tank capacity [l] Working volume [l] A [mm] B [mm]
30 (steel) 9 7.5 304 188
31 (steel) 15 12 464 348
32 (steel) 25 20 724 608
40
A
A1
73,5 147
183
21
11
M
T
P
183
A
114
T P
M
A111
40
138106
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 15
Tank Dimensions Dimensions in millimeters
Power pack with cylindrical plastic tank - mounting position horizontal
Plastic tanks are not UV stable. Place the unit in the shade for outdoor application.
Power pack with cylindrical plastic tank - mounting position vertical
Plastic tanks are not UV stable. Place the unit in the shade for outdoor application.
Code of the tank Tank capacity [l] Working volume [l] A [mm] A1 [mm]
40 (plastic) 6 3.7 280 61
42 (plastic) 8 4.9 360 121
44 (plastic) 10 6.1 440 201
Code of the tank Tank capacity [l] Working volume [l] A [mm] A1 [mm]
41 (plastic) 6 3.7 280 61
43 (plastic) 8 4.9 360 121
45 (plastic) 10 6.1 440 201
141,5
73,5
40
40
A
M
T
P
160
170
E
12
160
A
T P
M
40
130
MAX
MIN
MIN
MAX
170
12
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 16
Tank Dimensions Dimensions in millimeters
Power pack with square plastic tank - mounting position horizontal
Plastic tanks are not UV stable. Place the unit in the shade for outdoor application.
Code of the tank Tank capacity [l] Working volume [l] A [mm]
61 (plastic) 2 1.3 178
63 (plastic) 4 3.5 270
65 (plastic) 6 5.5 359
67 (plastic) 8 7.5 449
69 (plastic) 10 9.5 543
Code of the tank Tank capacity [l] Working volume [l] A [mm] E [mm]
62 (plastic) 2 1.7 178 -
64 (plastic) 4 3.0 270 120
66 (plastic) 6 4.5 359 165
68 (plastic) 8 6.0 449 208
70 (plastic) 10 7.5 543 208
Power pack with square plastic tank - mounting position vertical
Plastic tanks are not UV stable. Place the unit in the shade for outdoor application.
138,5
40
A3
M
99
43
P
P
A2
A8
A4 A6
A1
A5
C121
4x d
R=1/2d - 4x
T P
40
B
M
D
T
P
C
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 17
Tank Dimensions Dimensions in millimeters
Configuration B, E
Code of the tank Tank capacity [l] Working volume [l] A1 A2 A3 A4 A5 A6 A7 A8 d
56 (steel) 8 4.5 280 340 165 319 220 10.5 30 100 9
57 (steel) 10 8 280 400 188 388 220 6 30 100 9
58 (steel) 20 16 280 400 276 388 220 6 30 100 9
59 (steel) 30 24 320 500 287 479 260 9.5 30 132 11
60 (steel) 40 34 320 500 366 479 260 9.5 30 132 11
Dimensions C see Table of Dimensions - page 10
Power pack with square steel tank - one-phase and three-phase motors with return line filter
There is limited possibility to use hand pump
together with the tanks 56-60.
It is possible to use it only in this position if here
is no return filter on the tank cover.
Power Pack Dimensions in millimeters
6+1 Nm
(4.4+0.7 lbf.ft)
Power pack with cylindrical steel tank - with DC electric motor without return line filter
B
E
L
U
F
T
U
N
G
S
F
I
L
T
E
R
I
A
I
R
B
R
E
A
T
H
E
R
ARGO
L
1
-
0
4
0
6
-
A8
C
121
T P
P
P
11
6
3
10
P
A1
A2
B1
B2
8
7
9
2a
4
2
1a
1
5
1b
Plug
Starting module
Subject to change · SMA 05_7212_1en_02/2016
www.argo-hytos.com
Page 18
Power Pack Dimensions in millimeters
Power pack with square steel tank - with DC electric motor without return line filter
Optional stacking assembly, versions B, E ref. page 13.
Dimensions B, C, D see Table of Dimensions - page 10
Dimensions A8 see Table of Dimensions - page 17
SMA05 - Ilustration Figure
1 AC motor
1a AC motor flange spacer
1b AC motor coupling (diff. types)
2 DC motor
2a DC motor coupling
3 Tank with accessories (diff. types)
4 Center block versions A, B, C, D, E
5 Pump (diff. types)
6 Suction filter and pipe
7 Return line
8 Base-plate for different types of stacking assembly
9 Cover plate for horizontal stacking
10 Stacking assembly valves
11 Foot bracket