1
HA 5227
7/2008
M27 x 2 • p
max
350 bar • Q 60 L/min
3 Way
Flow Control Valves
SF32A-K3/l
q
Priority style
q
Constant flow largely independent to load
and viscosity
q
Port 2 can be pressurized
q
Various flow ranges available
Functional Description
Replaces
HA 5227 9/2006
The valve consists of an adjustable measuring orifice
plate after which it is installed a stabilizer of pressure
drop. During the flow from (1) to (3) the liquid flows
through the centre of the stabilizer slide valve and then
through radial orifices to the side channel (3).
The stabilizer has been designed to serve for
maintaining a pressure difference arisen on
the measuring orifice plate at a constant level
of approximately of 12 bar given by the spring force so as
to ensure a constant rate of flow through the channel (3).
The excessive flow of the liquid cause a dynamic
pressure in channel (1) by means of which the slide valve
of the stabilizer is shifted against the spring and opens
the flow cross section to the channel (2) through which
the excessive liquid flows out either to the drain or to
another consumer. The channel (2) can be loaded by
pressure. Due to permanent equalizing the forces
the position of the stabilizer gate valve changes with
each change of pressure before and after the measuring
orifice plate and in this way it results in appropriate
decreasing or eventually appropriate increasing the flow
cross section of channels.
The liquid can flow through the valve also in opposite
direction from (3) to (1), however, in a limited extent
taking into consideration the fact that the liquid shall flow
through the throttling cross section.
As for appropriate basic surface finish the external parts
are zinc coated.