HA 5218
12/2014
M27 x 1.5 • p
max
350 bar • Q 90 L/min
Pilot Operated Check Valves
SC5H-R3/l
q
Load-holding without leakage
q
Low pressure drop
q
Optional pilot seal
q
The valve should be mounted as close as possible
to the actuator
q
Fits the same cavity as the R3 overcentre valve
Replaces
HA 5218 7/2008
The design of the valve fitted with conical seat ensures
hermetical closing in one direction and in the other
direction of flow with a small pressure drop. The valve
remains shut off closely if the pressure in channel (1) is
equal to or higher than the pressure in channel (2) and
no pressure and / or insufficient pressure only is exerted
in the channel (3). As soon as the pressure in the channel
(2) exceeds the pressure in the channel (1) including
pressure caused by the spring the valve opens the flow
from (2) to (1). If the liquid has to flow through the valve
from (1) to (2) the control pressure should be introduced
in the channel (3). As soon as this pressure attains
a necessary value the control gate valve is shifted
against the spring and moves the valve cone out
of the seat. At calculating the control pressure
it is necessary to take into consideration that pressure in
the channel (2) will increase the control pressure
by the same value multiplied by an effective differential
area. This effective differential area has a value of 1 – 1/4
at a rate of control areas of 4:1.
As for appropriate basic surface finish the external parts
are zinc coated.
Functional Description