1
The pressure valves VRP2 are directly operated
reducing valves for vertical stacking assemblies
designed as 3 way valves, i.e. with pressure protection of
the secondary circuit.
The valve consists of the valve body (1), control spool
(2), spring (3), adjustment element (4) and the plug
G 1/4 (5) for pressure measuring and, if necessary, of a
check valve.
Model “A”
With this model, the fluid enters into the valve body from
the primary circuit through port A1 and passes through
the metering edge, where its pressure is reduced. The
reduced pressure corresponds with the setting of the
control spring. At the same time, this pressure affects
also the surface area of the control spool opposed to the
spring (the pressure can be measured at the port G 1/4
which is normally closed by plug 5). Thus the static
balance of the spool is ensured. If the reduced pressure
changes, a respective control action takes place and the
reduced pressure returns to its preset value. The flow
from the output port A2 passes then to the user. If
pressure behind the valve increases due to the effect of
the load acting on the user, the spool shifts further
against the spring until the second metering edge opens
and the excessive flow drains through port T. The
leakage from the spring room is also routed to port T.
The reverse free-flow from port A2 to port A1 passes
through a check valve which is connected parallel to the
metering edge.
Model “B”
With model “B”, the pressure reduction follows from port
P2 to port P1, but it takes place only when the flow in port
B passes in the direction to the user (not opposite). The
protection of the secondary circuit is also ensured for
one flow direction only.
Model “P”
With model “P”, the pressure reduction follows from port
P2 to port P1, but is effective in both flow directions
through the directional valve (as well as the protection of
the secondary circuit).
The valves are delivered with basic surface treatment.
The valve body is phosphate coated, whereas the
surfaces of the other parts are zinc coated.
HA 5142
6/2012
Replaces
HA 5142 4/2008
Size 04 (D 02) · 320 bar (4600 PSI) · 20 L/min (5.3 US GPM)
Directly Operated Pressure
Reducing Valves
VRP2-04
q
For stacking assemblies
q
4 pressure ranges
q
Pressure reduction in ports A or P
q
Model “A” with check valve
q
Installation dimensions to ISO 4401/CETOP-RP 121H
Functional Description