AA
A
BB B
1
HA 5132
4/2011
M12x1 •p
max
320 bar (4641 PSI) •Q
max
20 L/min (5.28 GPM)
Screw - in Cartridge Throttle
Valves
Throttle valve VSV2 is used to control
the flow in a hydraulic system in one or
both directions.
1) A higher sensitivity control is
achieved by using the M12x1
screw thread
2) After loosening the lock nut the
valve may be screwed out only up
to the red marked safety notch;
otherwise the valve could get
completely unscrewed leading to
working fluid escape.
Screw
inside HEX 6
Lock-nut
outside HEX 19
Ordering Code
VSV2 - /
Screw-in Cartridge Throttle Valve
Thread
M12x1 M12x1
Model
1
J1
J2
without check valve
with check valve, non regulated flow B®A
with check valve, non regulated flow A®B
VSV2
A
B
Functional Description
VSV2-J1
VSV2-1
VSV2-J2
B
A
B
A
B
A
VSV2-1
VSV2-J1
without check valve
with check valve,
non regulated flow BA®
VSV2-J2
with check valve,
non regulated flow AB®
Functional Symbols
Technical Data
Nominal size mm M12x1
Max. operating pressure bar (PSI) 320 (4641)
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51 524
Fluid temperature range °C (°F) -30 ... +100 (-22 ... +212)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Weight kg (Ibs) 0,11(0.243)
Mounting position unrestricted
q
Screw-in cartridge design
q
Use :
- Metering in one direction
- Metering in both directions
q
Flow rate set by adjustment screw internal
to hexagon lock-nut
Seals
6,73x9,43x1,14 NBR90
6,9x1,8 NBR70
2
HA 5132
Caution!
The packing foil is recyclable.
The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any way as a guaranteed representation of the product properties in any legal sense.
Subject to change without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: sales.cz@argo-hytos.com
www.argo-hytos.com
p-Q Characteristics Measured at n = 32 mm
2
/s (156 SUS )
Pressure p [bar (PSI)]
Flow Q [L/min (GPM)]
1 turn
2 turns
3 turns
4 turns
Cavity Dimensions in millimeters (inches)
Dp Characteristics Measured at n = 32 mm
2
/s (156 SUS )
Flow Q [L/min (GPM)]
Pressure drop Dp[bar (PSI)]
VSV2-J1 - Flow direction B ® A
VSV2-J2 - Flow direction A ® B
1 - Throttle valve closed
2 - Throttle valve open
3,2
1,6
A
0.1
A
3,2
39+0,4(1.535/1.551)
33+0,4(1.299/0.016)
15+1(0.590/0.630)
12,5+1(0.492/0.531)
Æ6H7(0.236)
Æ
24+0,5(0.945/0.965)
M12x1-6H
0,1 A
120°
30°
1 0,2(0.031/0.047)±
3,2
0,005 A
43+1(1.692/1.732)
Æ
10H8(0.394)
max 33( )1.299
min 28(1.102)
30+0,4(1.181/1.197)
( 5(0.197))Æ
-0.3(-0.012)
+0.3(0.012)