1
Model RJV1-05 are pilot operated check valves in
cartridge design used to give leakfree closure of a
hydraulic actuator port under pressure, even during
long idle periods.
They basically consist of housing (1), check valve (2),
and pilot piston (3). The cartridge is avaliable alredy
assembled into a subplate for direct mounting onto the
actuator (page 4 of this data sheet).
When fluid flows from port 2 ® 3, it opens the check
valve automatically. When the pressure in port 2 drops
(e.g. after shifting the directional valve into its middle
position), the spring pushes the ball (2) onto the seat
and the circuit between the check valve and the actuator
is closed. The control pressure (port 1) acting on the
pilot piston (3) moves the ball (2) from the seat and
makes the flow passage 3 ® 2 free. An additional port 4
is available for use in double acting applications using
two pilot operated check valves-see typical circuits
(page 3) and drawings (page 5).
The valve body is blackened. The hollow bolt and the
surface of the subplate are phosphate coated.
HA 5111
8/2012
Replaces
HA 5111 10/2011
Size 05 · 250 bar (3600 PSI) · 20 L/min (5.3 GPM)
Pilot Operated Cartridge Check
Valves
RJV1-05
Functional Description
q
Cartridge valve for manifold mounting and with
subplate
q
Model with subplate - enables direct moutingon
the hydraulic actuator by means of a hollow bolt
q
The use of a hollow bolt with a build-in throttle
VSV1 and check valve possible VSVJ1 and VSVJ2