1
q
Reducing valves suitable for mobile
applications
q
Compact design
q
Installation dimensions to ISO 7789
P
T
A
    
General Data
Design spool valve
Mounting mode screw-in cartridge M20 x 1.5
Mounting position optional
Flow direction see the symbol
Ambient temperature, max. °C (°F) -30 ...90 (-22 ...194), +100 °C (212 °F for a short term)
The reducing valve PVRM1 is a directly operated 3-way
valve controlled by proportional solenoid (1). In the
de-energized state, the spring (4) holds the control
spool (3) in relation to the housing in such a position that
the input pressure in port P is blocked, whereas the port
A is connected with tank. The electric current through
the solenoid shifts the spool and closes gradually the
return port and opens the inlet to the output port A. The
reduced pressure in port A brought to the solenoid
room acts on the differential area of the spool, this being
created by adapter (5). The solenoid pushes on the
spool with a force, which is proportional to the current.
Acting against this force is the force created by the
reduced pressure acting on the differential area. In a
balanced state, both the forces are equal. This
arrangement ensures the proportional relation between
the reduced pressure in port A and the control current.
The basic surface treatment of the solenoid is
blackened, other parts are zinc coated.
HA 5108
3/2008
Size to (06) · 50 bar (725 PSI) · 20 L/min (5.29 US GPM)
Proportional Reducing Valves
PVRM1-063/S
Replaces
HA 5108 01/2006
Functional Description
2
HA 5108
Solenoid Technical Data
Supply voltage V 12
Rated current A 1
Rated resistance at 20 °C (68 °F) W 7,1 ± 6. 5 %
Rated power W 22
Duty cycle % 100
Pressure tightness (dynamic) bar (PSI) 50 (725.19 )
Wire insulation class 200 from DIN IEC 60085
Electric connection 2- poles AMP Junior-Timer
Enclosure type to EN 60529 IP 65
Control PWM-signal 100 Hz
Quenching BZW 06 P28B
Valve Technical Data
Max. input pressure bar (PSI) 50 (725.19)
Operating pressure bar (PSI) 20 (289.86)
Max. flow rate L/min (US GPM) 20 (5.29)
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Viscosity range mm
2
/s (SUS) 10 … 800 ( 49 … 3920 )
Fluid temperature range °C (°F) -30 ...90 (-22 ...194), +100 °C (212 °F for a short term)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Response time at 100 % signal ms < 50
Valve Dimensions Dimensions in mm (inches) p-I Characteristics
Caution!
The technical information regarding the product
presented in this catalogue is for descriptive
purposes only. It should not be construed
in any case as a guaranteed representation
of the product properties in the sense of the law.
60 (2.362)
70(2.756)
115(4.528)
min. 32(1.260)
Æ
Æ
15.5+0.05(0.610+0.002)
Æ
17+0.05(0.669+0.002)
Æ
21.8+0.1
( 0.858+0.004)
Æ
min.46 (1.811)
Æ
37+0.4(1.457+0.016)
Æ
21+0.4(0.875+0.016)
Æ
14.5+1(0.571+0.39)
max.2 (0.079)
Æ
6 (0.236)
Æ
6 (0.236)
2.4+0.4(0.094+0.016)
17.5 0.2(0.689 0.008)±±
33.5 0.2(1.319 0.008)±±
M20x1.5
R 0.2
(R 0.008)
R 0.4
(R 0.016)
Current I mA][
Pressure ]()[bar PSI
22
20
8
0 200 400 600 800 1000 1200
4
12
16
(50)
(100)
(150)
(200)
(250)
(300)
(319)
Dp-Q Characteristics
Pressure difference
p bar ( )D PSI ][
Flow Q ( ][L/min US GPM)
()20
()40
()60
()80
()100
7
6
5
4
3
1
2
0 5 10 15 20
A-T
P-A
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: sales.cz@argo-hytos.com
www.argo-hytos.com