1
q
Cartridge design
q
Flow rate setting with adjustment screw
q
For use in meter-in, meter-out
and bleed-off applications
Pressure compensated flow control valves VSS3-062
are employed in hydraulic systems where only small
speed or revolution variation due to load changing are
required.
The valve consists basically of throttling orifice (1),
pressure compensator (2), bushing (3), adjustment
screw (4) and spring (5).
Throttling in direction A ® B takes place on the throttling
orifice. The flow rate depends on the orifice diameter
and on the pressure difference at the orifice. The
pressure difference can be adjusted in a certain range
through preloading the spring (5), which results in the
respective flow change. The allocation of the orifice
diameters and the corresponding flow rates is apparent
from the respective characteristics. The flow rate
adjustment can be accomplished by adjustment screw
(4). The clockwise rotation increases the flow rate, the
anticlockwise rotation decreases the flow rate.
The flow rate stabilization is provided for by pressure
compensator (2), which is situated behind the throttling
orifice and mounted into bushing (3). The pressure
compensator continuously compares the pressure
difference at the throttling orifice (1) with the value given
by the spring parameters and the spring preloading and
accomplishes the necessary control actions, thus
holding the flow rate constant.
The valve cannot be closed. As mentioned above, only
small flow rate adjustments can be realized.
In flow direction B ® A, the valve works as an ordinary
throttle valve. The pressure losses depend on the orifice
diameter – see the respective characteristics.
The valve housing (7), the nut (6) and the adjustment
screw (4) are zinc coated.
HA 5057
5/2006
Replaces
HA 5057 1/2000
Size 06 · p
max
up to 320 bar · Q
max
up to 45 L/min
2-way cartridge flow control
valves
VSS3-062
Functional Description
AA
B