1
Functional Description
Double throttle valves are used to control flow rates in
two separate lines (A, B) of a hydraulic circuit. The
modular design provides six functional symbols.
The throttle valve is built into channel A or B or into
channels A and B. The valve restricts the fluid flow in one
direction while providing reverse free-flow in the
opposite direction. The throttling spool (2) is adjusted
by means of a set screw (3) and each spool position
corresponds with a certain passage area.
Fluid entering port A1 is throttled to port A2 via a groove
and an annulus area. Fluid returning from port B2 shifts
the valve seat (4) against the spring (5), thus creating a
passage which allows reverse free-flow to port B1
(function as a check valve).
The sandwich design enables simple stacking with
other components of the same size.
The separate O-ring plate (6) with fitted O rings provides
sealing of the valve connecting surface. According to
the valve arrangement, the meter-in or meter-out control
is provided. Changing the meter-in mode into the
meter-out mode can be done by turning the valve by
180° around its horizontal axis. The orientation of the
throttle check valves in the valve body corresponds with
the symbols shown on the name plate. The set screw
can be operated by a key, by a hand knob or by a hand
knob with keylock.
The basic surface treatment of the valve housing is
phosphate coated, whereas the surfaces of the other
parts are zinc coated.
q
Sandwich plate design for use in vertical stacking
assemblies
q
Meter-in or meter-out control as required
q
Three possible arrangements:
- throttle valve in channel A
- throttle valve in channel B
- throttle valves in channels A and B
q
Flow adjustment - three adjustment elements
q
Installation dimensions to ISO 4401:1994
and DIN 24 340-A6
q
Subplates - see Catalogue HA 0002
HA 5051
7/2012
Replaces
HA 5051 5/2008
Size 06 · p
max
320 bar · Q
max
80 L/min
Double Throttle Check Valves
Sandwich Plates
2VS3-06