1
A pilot operated check valve closes tightly the hydraulic
circuit between the valve and the actuator. The valve
consists of the housing (1), one or two check valves (2),
(3) and the pilot piston (4). The main poppets of the
check valves are provided with pilot poppets (5) which
enable opening the check valve under pressure.
When fluid flows from A1 to A2 it opens the check valve
(2) and at the same time shifts the pilot piston (4) which
opens by means of the pilot poppet (5) the check valve
(3). When the pressure in channels A1 and B1 drops, the
springs push the poppets onto the seats and the circuit
between the check valve and the actuator is closed
under pressure.
To ensure that the check valves close tightly, a
directional valve with functional symbol Y is to be used,
which connects in its middle position the ports A1 and
B1 with tank T (see the typical circuit diagram).
The valve housing (1) is phosphate coated, the surfaces
of the other parts are zinc coated.
HA 5025
6/2012
Size 10 (D 05) · 350 bar (5076 PSI) · 100L/min (26.4 GPM)
Pilot Operated Check Valves
Sandwich Plates
VJR2-10/M
Replaces
HA 5025 2/2008
q
Pilot operated check valve sandwich plate
for use in stacking assemblies
q
3 models
- double valve with check valves in lines A and B
- single valve with check valve in line A
- single valve with check valve in line B
q
Installation dimensions to SO 4401
CETOP - RP 121H and NFPA T3.5.1 - D 02
Functional Description