1
Functional Description
A pilot operated check valve is used to provide leakfree
closure of a hydraulic circuit under pressure. It protects
the load against dropping should a line break occur and
ensures a stable position of a hydraulic actuator under
pressure, even during long idle periods.
The valve basically consists of housing (1), one or two
check valves (2), (3) and pilot piston (4).
When fluid flows from A1 (B1) to A2 (B2) it opens the
check valve (2), (3) and at the same time shifts the pilot
piston (4) to the right (left), thus opening the way B2®B1
(A2®A1). When the pressure drops (e.g. after shifting
the directional valve into its middle position), the springs
push the balls onto the seats and the circuit between the
check valve and the actuator is closed under pressure.
To ensure that the ball valves seat properly and that they
perfectly close ports A2 and B2, a directional valve with
functional symbol Y is to be used, which connects in its
neutral position both sides of the pilot piston (4) with
tank.
The valve housing surface is phophate coated, the
surfaces of the other parts are zinc coated.
HA 5023
5/2012
Size 04 (D 02) · 320 bar (4600 PSI) · 20 L/min (5.3 GPM)
Pilot Operated Check Valves
Sandwich Plates
VJR1-04/M
Replaces
HA 5023 5/2008
q
Sandwich plate design for use in vertical stacking assemblies
q
3 models:
- leakfree closure of both sides with check valves
in lines A and B
- leakfree closure with check valve in line A
- leakfree closure in line B
q
Installation dimensions acording to
ISO 4401 / DIN 24 340