1
Functional Description
The check valves sandwich plate are used to allow flow
in one direction and prevent flow in the other in the port
in which the check element is installed. The sandwich
design enables stacking with other components of the
same size. The check elements are build into one or two
ports, the other ports being through-holes. The seat (3)
is machined directly in the housing (1) and the poppet
(2) is pushed onto the seat by the compression spring
(4). The cracking pressure depends on the spring
selected and the pressurised poppet surface area.
The valve housing surface is phosphate coated.
Model A Model D
   
   
HA 5012
7/2012
Size 04 (D 02) · 320 bar (4600 PSI) · 30 L/min (7.9 GPM)
Check Valves Sandwich Plates
VJO1-04/M
Replaces
HA 5012 4/2008
q
Sandwich plate design for use in vertical stacking
assemblies
q
Poppet design
q
Leakfree closure in one or two service ports
q
8 different models
q
Installation dimensions
to ISO 4401 CETOP - RP 121H
2
HA5012
VJO1-04/M -
Cracking pressure
05
15
30
0.5 bar (7 PSI)
1.5 bar (22 PSI)
3.0 bar (43 PSI)
Valve size 04 (D 02)
Sandwich Check Valve Plate
for Stacking Assemblies
Sandwich plate design
Seal
no designation
V
NBR
FPM (Viton)
Ordering Code
Valve size mm (US) 04 (D 02)
Maximum flow L/min (GPM) 30 (7.94)
Maximum operating pressure bar (PSI) 320 (4600)
Cracking pressure bar (PSI) 0,5 (7) 1,5 (0.4) 3 (0.8)
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range
for standard sealing (NBR)
°C (°F) -30 ... +100 (-22... +212)
Fluid temperature range
for Viton seals (FPM)
°C (°F) -20 ... +120 (-4... +248)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Weight kg (lbs) 0,40 (0.879)
Mounting position unrestricted
Technical Data
Notes: Symbol orientation on the label corresponds with the valve function.
valve side
subplate or manifold side
ABEF
DPTH
Functional Symbols
A
B
E
Check valve in line * A
Check valve in line * B
Check valve in line * A
F
D
P
Check valve in line * B
Check valves in lines * A and B
Check valve in line * P
T
H
Check valve in line * T
Check valves in lines * P and T
* see the table Functional symbols
Functional symbols
/
/
3
HA5012
Valve Dimensions Dimensions in imillimeters (inches)
10
9
8
7
6
5
4
3
2
1
0
10
20
25
30
15
7.93
30
45
60
75
90
105
120
135
145
1
2
3
4
5
6
7
( )
15
( )
( )
( )
( )
( )
( )
( )( )
( )( )( )( )
( )( )( )( )
( )( )( )( )
5
( )
( ) ( )
( )
( )
( )
( )
Pressure drop Dp [bar (PSI)]
Flow Q [L/min (GPM)]
Required surface finish
of interface
2
3
1
Dp-Q Characteristics Measured at n = 32 mm
2
/s (156 SUS)
Pressure drop Dp related to flow rate.
Dimensions in millimeters:
1 Name plate
2 4 through mounting holes
3 Square ring (4 pcs.):
standard (NBR) - SR 010 6.07 x 1.68
Viton (FPM) - 6.07 x 1.78
supplied with valve
4
HA5012
Seal kit
Type
Dimensions, quantity
Ordering number
Square ring O-ring
Standard NBR 6,07 x 1,68 (4 pcs.) - 15946100
Viton - 6,7 x 1,78 (4 pcs.) 22662600
Spare Parts Dimensions in millimeters
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: sales.cz@argo-hytos.com
www.argo-hytos.com
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.