(145)
(72.5)
(217.6)
(290.1)
0
510
15
20
5
10
15
20
(1.32) (2.64) (3.96) (5.28)
1
3
2
4
5
S5, S6
04
(145)
(72.5)
(217.6)
(290.1)
0
510
15
20
5
10
15
20
(1.32) (2.64) (3.96) (5.28)
1
3
2
06
S5, S6
ROE3-042 / -
S5
S6
01200
01400
02100
02400
02700
20500
02450
12060
23050
MA
MB
MX
MD
ME
MC
MF
MG
MP*
MJ
MI
R1
R2
R3
R4
R7
E1
E2
E3
E4
E3A
E4A
E5
E8
E9
E12A
E13A
04
06
Subject to change · ROE3-042S5(S6)/M_4073_2en_03/2019
www.argo-hytos.com
Page 2
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
S5 Model Direction
1
MD04 A-T, T-A
ME04 B-T, T-B
MF04
A-T, T-A
A-T, B-T
T-A, T-B
2 MX04 A-B, B-A
3
MA04
A1-A2
A2-A1
MB04 B1-B2, B2-B1
MC04
A1-A2, A2-A1
B1-B2, B2-B1
Flow Q [l/min (GPM)]
∆p, p
Emin
[bar (PSI)]
Ordering Code
Pressure drop related to flow rate
Modular plate M*
S6 Model Direction
2
MD04 A-T, T-A
(to 20 l/min)
ME04 B-T, T-B
MF04
A-T, B-T
T-A, T-B
4 MX04 A-B, B-A
5
MA04 A1-A2, A2-A1
MB04 B1-B2, B2-B1
MC04
A1-A2, A2-A1
B1-B2, B2-B1
S5 Model Direction
1
MD06 A-T, T-A
ME06 B-T, T-B
MF06 A-T, B-T / T-A, T-B
2
MA06 A1-A2
MB06 B1-B2
MC06 A1-A2 / B1-B2
MX06 B-A
3
MA06 A2-A1
MB06 B1-B2
MC06 A2-A1 / B2-B1
MX06 A-B
S6 Model Direction (to 20 l/min)
1
MD06 T- A
ME06 T-B
MF06 T-A, T-B
2
MD06 A-T
ME06 B-T
MF06 A-T, B-T
3
MA06 A1-A2, A2-A1
MB06 B1-B2, B2-B1
MC06
A1-A2, A2-A1
B1-B2, B2-B1
∆p, p
Emin
[bar (PSI)]
Flow Q [l/min (GPM)]
Model
modular valve, connection A2-A1
modular valve, connection B2-B1
modular valve, connection A-B
modular valve, connection A-T
modular valve, connection B-T
modular valve, connection B2-B1, A2-A1
modular valve, connection B-T, A-T
modular valve, connection P-T
modular valve, connection P2-P1
modular valve, connection B2-P2, B2-T2
modular valve, connection A-T, B2-B1
in-line valve, 2 ports, thread G3/8
in-line valve, 2 ports, thread G1/2
in-line valve, 2 ports, thread SAE 8, 3/4-16
in-line valve, 2 ports, thread SAE 10, 7/8-14
in-line valve, 2 ports, thread SAE 10, 7/8-14
2/2 directional valve,
solenoid operated, poppet type,
blocking, direct acting, modular
*only available for size 06 (D03)
Modular plate size
ISO 4401-02-01-0-05, DIN 24340 (CETOP 02), size 04
ISO 4401-03-02-0-05, DIN 24340 (CETOP 03), size 06
normally closed (NC),
blocking
normally open (NO),
blocking
Rated supply voltage of solenoids (at the coil terminals)
12 V DC / 2.41 A
14 V DC / 1.66 A
21 V DC / 1.31 A
24 V DC / 1.15 A
27 V DC / 0.89 A
205 V DC / 0.12 A
24 V AC / 1.44 A / 50 (60) Hz
120 V AC / 0.22 A / 50 (60) Hz
230 V AC / 0.12 A / 50 (60) Hz
The AC coils correspond to E5.
Connector type
EN 175301-803-A
E1 with quenching diode
AMP Junior Timer - radial direction (2 pins; male)
E3 with quenching diode
AMP Junior Timer - axial direction (2 pins; male)
E3A with quenching diode
EN 175301-803-A with integrated rectifier
loose conductors (two insulated wires)
E8 with quenching diode
Deutsch DT04-2P - axial direction
E12A with quenching diode
No designation
V
Seals
NBR
FPM (Viton)
No designation
A
B
Surface treatment
standard
zinc-coated (ZnCr-3), ISO 9227 (240 h)
zinc-coated (ZnNi), ISO 9227 (520 h)
No designation
N2
N4
Manual override
standard
covered with rubber boot
with hand screw