SD1EX-A3
3/4-16 UNF • Q
max
30 l/min (8 GPM) • p
max
350 bar (5100 PSI)
Subject to change · SD1EX-A3_4068_1a_05/2015
Page 1
www.argo-hytos.com
Explosion-proof, 3/2 Directional Valve, Solenoid Operated, Poppet Type, Direct-Acting
Valve and solenoid design prevents a surface temperature capable of igniting
Solenoid coil in acc. with directive 94/9/EC (ATEX) for explosion-hazard zones
High ow capacity and transmitted hydraulic power up to 350 bar
Hardened and precision working parts
All ports may be fully pressurised
In the standard version, the valve is zinc-coated for 520 h protection acc. ISO 9227
Technical Features
EPS14ATEX1744 X
AC
l M2 Ex mb I Mb
lI 2G Ex mb IIB T4, T5, T6 Gb
lI 2D Ex mb IIIC T135°C, T100°C, T85°C Db
DC
l M2 Ex e mb I Mb
lI 2G Ex e mb IIB T4, T5, T6 Gb
lI 2D Ex tb IIIC T135°C, T100°C, T85°C Db
IECEx EPS14.0064 X
AC
Ex mb I Mb
Ex mb IIB T4, T5, T6 Gb
Ex mb IIIC T135°C, T100°C, T85°C Db
DC
Ex e mb I Mb
Ex e mb IIB T4, T5, T6 Gb
Ex tb IIIC T135°C, T100°C, T85°C Db
Technical Data
Valve size / Cartridge cavity 3/4-16 UNF-2A / A3
Max. ow l/min (GPM) 30 (7.9)
Max. operating pressure bar (PSI) 350 (5080)
Fluid temperature range °C (°F) -30 ... +70 (-22 ... +158)
Max. switching frequency 1/h 15 000
Weight with coil kg (Ibs) 1,51 (3.33)
Technica Data - Explosion proof Solenoid
Voltage type AC 50 / 60 HZ DC
Available voltages V 110, 230 12, 24, 48, 110
Available nominal power W 10
Supply voltage tolerance % AC, DC ± 10
Duty cycle S1 (100%ED)
Enclosure type of the Solenoid to EN 60529 IP 65
Weight (solenoid only) kg (Ibs) 1,3 (2.87)
Ambient temperature range
Temperature class /
Nominal power
T4 / 10 W
°C (°F)
-30 ... +70 (-22 ... +158)
T5 / 10 W -30 ... +55 (-22 ... +131)
T6 / 10 W -30 ... +45 (-22 ... +113)
Data Sheet Type
General information GI_0060 products and operating conditions
Coil types C_8007 74 EX 18
Bodies for
valves
In-line mounted SB_0018 SB-A3*
Sandwich mounted SB-04(06)_0028 SB-*A3*
Cavity details / Form tools SMT_0019 SMT-A3*
Spare parts SP_8010
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
Operating pressure p [bar (PSI)]
Flow Q [l/min (GPM)]
(2175)
( 900)2
( 450)1
( )
4060
( )4640
( )2900
( )3480
0
5
10
15
20 25
100
150
5
300
350
200
250
( . )13 ( . )26 ()4.0 ( . )66 ( .9)7( . )53
30
400
(725)
(9.2) (10.6)
4035
21
1, 2
Direction 23 32 21 12
1 2 2 2
Pressure drop Dp [bar (PSI)]
Flow Q [l/min (GPM)]
Connection Direction
1 2S7 12, 21, 23, 32
10
20
30
40
( . )13 ( . )26
( . )40
( . )53 ( . )66 ( .9)7
5
10
15 20 25 30
0
( )145
( )290
( )435
( 0)58
1
Ambient temperature 70 °C (158 °F), Voltage U
n
-10% (24 VDC), Power P
n
10 W
Operating limits Pressure drops Δp-Q
ATEX/IECEx Classification
85 (3.35)
3/4-6UNF-2A
46 (1.81)
43 (1.69)
40 (1.57)
81,5 (3.21)
128(5.04)
16 (0.63)58 (2.28)
46 (1.81)
36 (1.42)
70 (2.76)
97 (3.82)
15,82 (0.62)
14,22 (0.56)
6 8 ( )÷ 0.24 .31÷0
85 (3.35)
5+1 Nm
(3.7+0.7 lbf.ft)
4+0,5 Nm
(3.0+0.37 lbf.ft)
No designation
- standard
cable diameter
Subject to change · SD1EX-A3_4068_1a_05/2015
Page 2
www.argo-hytos.com
Dimensions in millimeters (inches)
Manual Override in millimeters (inches)
Ordering Code
SD1EX-A3 / -
DC voltage
Connection box + Cable gland
12 V DC
24 V DC
48 V DC
110 V DC
AC voltage 50/60 Hz
Fix Installed cable
110 V AC
230 V AC
01200
02400
04800
11000
11050
23050
B
Surface treatment
520 h salt spray test (ISO 9227)
No designation
Seals
NBR
Manual override
standard
No designation
Cable lenght
without cable
3 m
8 m
No designation (only for DC)
3 (only for AC)
8 (only for AC)
A4
A6
Temperature class - Solenoid nominal power
Class T4 - 10W
Class T6 (T5) - 10W
Explosion-proof, 3/2 Directional
Valve, Solenoid Operated,
Poppet Type, Direct-Acting
3/4-16 UNF
High performance
H
Description
2S7
2
31
-
Subject to change · SD1EX-A3_4068_1a_05/2015
Page 3
www.argo-hytos.com
Samples of Marking
Marking of Solenoid
Subject to change · SD1EX-A3_4068_1a_05/2015
Page 4
www.argo-hytos.com
Information for Customers
The ambient temperature range shall not overstep the temperatures given in the chapter Technical Data - Explosion proof solenoid (page 1).
The maximum temperature of the medium (generally hydraulic uid) shall not exceed 70 °C (158 °F).
It is the users duty to ensure free and unhindered heat emission during operation. This means that the solenoid shall neither be covered not stored
immediately adjecent to heat sources (e.g. fan heaters) during operation.
Care is to be given that the solenoid is not subjected to direct sunlight during operation.
Initial installation
Installing the type VDC for temperature class T4 a cable with an ambient operating temperature of at least +105 °C (+221°F) is to be used.
For T5 and T6 a cable with an ambient operating temperature of a least +90 °C (+194°F) is sufcient. The fastening torque on the cable
gland depends of the used cable and is to be determined by installing user.
When installing the VDC solenoid type, please note the fastening torque of the screws (4 Nm or 2.95 Lbf.ft)
and of the Connection box (0,4 Nm or 0.30 Lbf.ft).
When installing the VDC solenoid type, an appropriate cable shoe M3 - 0,75 mm2
( with an ambient operating temperature of at least +105 °C or +221°F) is to be used.
The user has to safeguard each solenoid with a fuse: IN ≤ 3xIG, with tigger characteristic “slow blow”.
The breaking capacity of the fuse link has to be stronger than the max short circuit current at the users operating area.
EX-secured components must be used during mounting in case the fuse and/or the interface are within the EX-range.
In addition, the solenoid may be connected to ground via the purpose-built ground clamp an the connector casing.
Installation notice - installation, mounting, demounting
In case the solenoid shows any signs of a defect, malfunctioning or external damage (including corrosion), the device must
immediately be taken out of operation.
Any deposits on the surface of the device shall not obstruct heat emission.
To maintain legibility of the date plate, the solenoid must not be coated.
Safety notice - Please read carefully
Always disconnect the solenoid from the power supply before any maintenance or other work on it.
Always exchange the complete solenoid. Do not try to repair the solenoid.
In no case shall any changes be made to the solenoid or the connecting cable.
Demount the solenoid only in secure areas (not in EX-areas). If this is not possible, the solenoid must cool for 10 minutes minimum.
Caution