Explosion-proof, 4/2 and 4/3, Directional Control Valve, Solenoid Operated
Valve and solenoid design prevents a surface temperature capable of igniting
Solenoid coil in acc. with directive 94/9/EC (ATEX) for explosion-hazard zones
High flow capacity and transmitted hydraulic power up to 350 bar
4/3 and 4/2 directional spool valve
Variety of optional spools connections
In the standard version, the valve housing and steel parts are zinc-coated for 520 h
protection acc. ISO 9227
Mounting surface according to ISO 4401, DIN 24340 (CETOP RP121H) standards
Technical Features
ATEX/IECEx Classification
Size 06 (D03) • Q
max
60 l/min (16 GPM) • p
max
350 bar (5100 PSI)
The valves equipped with explosion-proof solenoids are available with following
certifications and protection modes:
EPS14ATEX1744 X IECEx EPS14.0064 X
AC
l M2 Ex mb I Mb Ex mb I Mb
lI 2G Ex mb IIB T4, T5, T6 Gb Ex mb IIB T4, T5, T6 Gb
lI 2D Ex mb IIIC T135°C, T100°C, T85°C Db Ex mb IIIC T135°C, T100°C, T85°C Db
DC
l M2 Ex e mb I Mb Ex e mb I Mb
lI 2G Ex e mb IIB T4, T5, T6 Gb Ex e mb IIB T4, T5, T6 Gb
lI 2D Ex tb IIIC T135°C, T100°C, T85°C Db Ex tb IIIC T135°C, T100°C, T85°C Db
0,75 (0.03)
5,1 0.20()
15,5 (0.61)
25,9 (1.16)
31
()1.22
31,75 (1.25)
TP
B
A
4xM5-6Hx13
12,7 0.50( )
21,5 0.85( )
30,2 1.18( )
40,5 1.59( )
G
Technical Data
ISO 4401-03 (CETOP 03)
Valve size 06 (D03)
Max. flow l/min (GPM) see p-Q characteristics
Max. operating pressure at ports P, A, B bar (PSI) standard 350 (5080)
Max. operating pressure at ports T bar (PSI) 210 (3050)
Pressure drop bar (PSI) see Δp-Q characteristics
Fluid temperature range (NBR) °C (°F) -30 ... +70 (-22 ... +158)
Supply voltage tolerance % AC: ± 10 DC: ± 10
Max. switching frequency 1/h 15 000
Switching time ON at ν=32 mm
2
/s (156 SUS)
ms
AC: 30 ... 40 DC: 30 ... 50
Switching time OFF at ν=32 mm
2
/s (156 SUS)
ms AC: 30 ... 70 DC: 10 ... 50
Weight
valve with 1 solenoid
kg (Ibs)
2,52 (5.56)
valve with 2 solenoids 3,97 (8.75)
Technical Data - Explosion proof Solenoid
Voltage type AC 50 / 60 HZ DC
Available voltages V 110, 230 12, 24, 48, 110
Available nominal power W 10
Supply voltage tolerance % AC: ± 10 DC: ± 10
Duty cycle (100%ED)
Enclosure type of the Solenoid to EN 60529 IP 65
Ambient temperature range
°C (°F)
Temperature class /
Nominal power
T4 / 10 W -30 ... +70 (-22 ... +158)
T5 / 10 W -30 ... +55 (-22 ... +131)
T6 / 10 W -30 ... +45 (-22 ... +113)
Data Sheet Type
General information GI_0060 products and operating conditions
Coil types / Connectors C_8007 74 EX 18
Mounting surface SMT_0019 Size 06
Subplates Subplates_0002
Spare parts SP_8010
Ports P, A, B, T - max 7,5 mm [0.29 in]
RPEX3-06 / -
Ambient temperature 70 °C (158 °F), Voltage U
n
-10% (24 VDC), Power P
n
10 W
Subject to change · RPEX3-06_4054_1a_03/2015
Page 2
www.argo-hytos.com
Ordering Code
Number of valve positions
two positions
three positions
Explosion-proof, 4/2
and 4/3, Directional Control
Valve, Solenoid Operated
Valve size
2
3
Spool symbols
see the table Spool Symbols
DC voltage
Connection box + Cable gland
12 V DC
24 V DC
48 V DC
110 V DC
AC voltage 50/60 Hz
Fix Installed cable
110 V AC
230 V AC
01200
02400
04800
11000
11050
23050
B
Surface treatment
520 h salt spray test (ISO 9227)
No designation
Seals
NBR
Manual override
standardNo designation
Cable lenght
without cable
3 m
8 m
No designation (only for DC)
3 (for DC or AC)
8 (for DC or AC)
A4
A6
Temperature class - Solenoid nominal power
Class T4 - 10 W
Class T6 (T5) - 10 W
Spool Symbols
Type Symbol Interposition
Z11
C11
H11
Y11
R30
X30
B71
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
(116)
()174
()58
(290)
()406
8
16
4
0 20 30 40 50 60
(2.6) (5.3) (8.0) (10.6) (13.2) (15.9)
0 10
1
2
3
20
24
28
32
12
()232
(3 )48
(4 )64
4
PA PB AT BT PT PA PB AT BT PT
Z11 1 1 2 2 Y11 1 1 1 1
C11 3 3 3 4 2 R30 1 1 2 2
H11 1 1 1 2 2 X30 1 1 2 2
B71 1 1
Operating limits
Operating pressure p [bar (PSI)]
Pressure drop Dp [bar (PSI)]
Flow Q [l/min (GPM)]
Flow Q [l/min (GPM)]
Pressure drops Δp-Q
(1160)
(0
)174
(0)58
(0)522
(2900)
(0
)406
80
160
40
360
0 20 30 40 50 60
(2.6) (5.3) (8.0) (10.6) (13.2) (15.9)
0 10
1
2
3
1, 2, 3, 4
200
240
280
320
120
(0
)232
(3
0)48
(4
0)64
4
1, 2, 3, 4, 5
5
5
Z11 2 C11 5
Y11 3 R30 1
H11 4 X30 1
B71 4
Type Symbol Interposition Type Symbol Interposition
Subject to change · RPEX3-06_4054_1a_03/2015
Page 3
www.argo-hytos.com
Samples of Marking
Manual Override in millimeters (inches)
74 (2.91)
No designation
- standard
Designation N4
- with hand whee
Standard model of the manual override.
Standard retaining nut of the solenoid.
150 (5.90)
8 (0.31)
68 (2.68)
73,5 (2.89)
45,6 (1.8)
(89,5 ( )3.53)
215 ( )8.46
5,3 (0.2)
9,5 (0.4)
37,3 (1.47)
49,3 (1.94)
(261,7 (10.3))
A-A
24 (0.94)
(64,8 (2.55))
46 (1.81)
36
A
12,5 (0.49)
15,5 (0.61)
45,5 (1.79)
A
T
B
A
P
6 8 ( )÷ 0.24 .31÷0
Dimensions in millimeters (inches)
5+1 Nm
(3.7+0.7 lbf.ft)
cable diameter
4+0,5 Nm
(3.0+0.37 lbf.ft)
Marking of Body
Marking of Solenoid
Subject to change · RPEX3-06_4054_1a_03/2015
Page 4
www.argo-hytos.com
Information for Customers
The ambient temperature range shall not overstep the temperatures given in the chapter Technical Data - Explosion proof solenoid (page 1).
The maximum temperature of the medium (generally hydraulic fluid) shall not exceed 70 °C (158 °F).
It is the users duty to ensure free and unhindered heat emission during operation. This means that the solenoid shall neither be covered not stored
immediately adjecent to heat sources (e.g. fan heaters) during operation.
Care is to be given that the solenoid is not subjected to direct sunlight during operation.
Initial installation
Installing the type VDC for temperature class T4 a cable with an ambient operating temperature of at least +105 °C (+221°F) is to be used.
For T5 and T6 a cable with an ambient operating temperature of a least +90 °C (+194°F) is sufficient. The fastening torque on the cable
gland depends of the used cable and is to be determined by installing user.
When installing the VDC solenoid type, please note the fastening torque of the screws (4 Nm or 2.95 Lbf.ft)
and of the Connection box (0,4 Nm or 0.30 Lbf.ft).
When installing the VDC solenoid type, an appropriate cable shoe M3 - 0,75 mm2
( with an ambient operating temperature of at least +105 °C or +221°F) is to be used.
The user has to safeguard each solenoid with a fuse: IN ≤ 3xIG, with tigger characteristic “slow blow”.
The breaking capacity of the fuse link has to be stronger than the max short circuit current at the users operating area.
EX-secured components must be used during mounting in case the fuse and/or the interface are within the EX-range.
In addition, the solenoid may be connected to ground via the purpose-built ground clamp an the connector casing.
Installation notice - installation, mounting, demounting
In case the solenoid shows any signs of a defect, malfunctioning or external damage (including corrosion), the device must
immediately be taken out of operation.
Any deposits on the surface of the device shall not obstruct heat emission.
To maintain legibility of the date plate, the solenoid must not be coated.
Safety notice - Please read carefully
Always disconnect the solenoid from the power supply before any maintenance or other work on it.
Always exchange the complete solenoid. Do not try to repair the solenoid.
In no case shall any changes be made to the solenoid or the connecting cable.
Demount the solenoid only in secure areas (not in EX-areas). If this is not possible, the solenoid must cool for 10 minutes minimum.
Caution