2
HA 4050
Ordering Code
Functional Symbols
Designation Symbol Interposition
Designation Symbol Interposition
Valve cavity
D17 (mm) (0.669 in)
Y
D20 (mm) (0.787 in) W
D20 (mm) (0.787 in) X
3/2 Way cartridge Directional
Valve Solenoid Operated
Slip-In
Type of construction 1
Number of operating positions 2
Functional Symbols
D21
D26
Number of connections 3
-
Seals
no designation NBR
V FPM (Viton)
Nominal supply voltage
12 12 V DC / 1,67 A
24 24 V DC / 0,84 A
PD2E / -
E4
Electronics
with AMP-Junior-Timer-connector
with integrated quenching diode and
terminal for AMP-Junior-Timer
connector with DEUTSCH DT 04-2P
with integrated quenching diode
and terminal for DEUTSCH DT 04-2P
E12A
E13A
E3
Standard
Mounting mode D17 D20
Maximum flow L/min (GPM) 30 (7.93)
Max.operating pressure in Canals Y, X -2, 3, W-3 bar (PSI) 80 (1160)
Max.operating pressure in Canals Y, X -1, W-2 bar (PSI) 30 (435)
Pressure drop bar (PSI) see Dp-Q characteristisc
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range °C (°F ) -30 ...90 (-22 ...194), +100 °C (212 °F for a short term)
Ambient temperature, max. °C (°F ) -30 ...90 (-22 ...194), +100 °C (212 °F for a short term)
Viscosity range mm
2
/s (SUS) 10 ... 500 (49 ... 2450)
Supply voltage V 12 DC 24DC
Quenching (E4, E13A) BZW06-19B BZW06-33B
Maximum degree of fluid contamination Class 21/18/15 according to ISO 4406
Supply voltage % ± 10
Quenching (E4, E13A) hod
-1
15 000
Duty cycle % 100
Enclosure type to EN 60529 IP 67
Service life 10
7
Weight Directional Control Valves kg (Ibs) 0.2 (0.44)
Maximum fixing bolt tightening torque Nm (lbf.ft) 9+2 ( 6.64+1.48)
Mounting positiion unrestricted
Technical Data