1
q
4/3, 4/2 way directional control valves
q
Four-land spool - reduced functional dependence
on fluid viscosity
q
Push button manual override
q
Installation dimensions to DIN 24 340 /
ISO 4401 / CETOP RP121-H
q
Subplates see data sheet HU 0002
q
CSA Upon request
HA 4044
5/2012
Size 10 (D 05) · 350 bar (5076 PSI) · 140 L/min (37 GPM )
Solenoid Operated Directional
Control Valves with Wirebox
RPEW4-10
The RPEW4 directional control valves consist of housing
(1), a control spool (5) with two centering springs (4) and
cylindrical operating solenoids (2, 3), electric wirebox (9)
and connector (6).
The three-position directional control valves are fitted
with two solenoids and two springs. Two-position
directional control valves have either one solenoid and
one return spring or two solenoids and a detent
assembly.
The solenoids are supplied with DC and AC - voltage
through the 1/2 NPT Ports on the wirebox (optional
on both sides) or through Connector Item (3 - Pin single
solenoid, 5 - Pin - double solenoid) see wiring diagram
(page 7). The wires are connected to a terminal plate
inside the wirebox. Optional lights are installed on this
terminal plate for shift indication. The lights are visible as
raised arrows on the valve label. The solenoids are
retained by the Nut (7) and plug-in to the wirebox. Plug
-in design allows easy removal without wire change.
In the case of solenoid malfunction or power failure,
the spool of the valve can be shifted by manual override
(8), provided the pressure in T- port does not exceed
25 bar (363 PSI).
The valve housing (1) is phosphate coated and the
solenoids (2, 3) are zinc coated.
Functional Description
Replaces
HA 4044 2/2006
2
HA 4044
Ordering Code
Functional symbols
see the table functional symbols
Valve Size 10 (05)
Solenoid Operated
Directional Control
Valve with Wirebox
Number of Valve Positions
two positions
2
three positions 3
Rated Supply Voltage of Wirebox (at the
wirebox terminals)
12 V DC / 2.64 A
01200
24 V DC / 1.32 A 02400
120V AC / 60Hz* 12060
* DC coils with rectifier in wirebox only type
of Wirebox R
Note: For other voltages consult factory
Type of Solenoid Coil for Wiring Box (Plug-In-Coil)
DC solenoid (DC and AC - rectified)
EW1
Seals
no designation NBR
V FPM (Viton)
Wirebox Configurations:
50 Standard wiring box with 1/2 NPT both ends
(Either side can be used for wiring, Remove
cover -plug accordingly)
51 Standard wiring box with 1/2 NPT both ends
and LED diodes (B- side plugged, A - side covert for
shipping)
52 Wiring box with 3 PIN connector ANSI/B93.55M
mounted on A-side (B-side plugged, only for single
solenoid valves)
53 Wiring box with 3 PIN connector ANSI/B93.55M
mounted on B-side (A-side plugged, only for single
solenoid valves)
54
Wiring box with 3 PIN connector ANSI/B93.55M
mounted on A-side with LED diode (B-side plugged,
only for single solenoid valves)
55 Wiring box with 3 PIN connector ANSI/B93.55M
mounted on B-side with LED diode (A-side plugged,
only for single solenoid valves)
56 Wiring box with 5 PIN connector ANSI/B93.55M
mounted on A-side (B-side plugged, only for double
solenoid valves)
57 Wiring box with 5 PIN connector ANSI/B93.55M
mounted on B-side (A-side plugged, only for double
solenoid valves)
58 Wiring box with 5 PIN connector ANSI/B93.55M
mounted on A-side with lLED diode (B-side plugged,
only for double solenoid valves)
59 Wiring box with 5 PIN connector ANSI/B93.55M
mounted on B-side with LED diode (A-side plugged,
only for double solenoid valves)
Type of Wirebox
Wirebox for DC
K
Wirebox AC rectified (rectifier in wirebox) R
RPEW4 - 10
Damping
no designation without damping
T2 nozzle
T3 throttle screw
Manual override
no designation standard
N2 covered with rubber boot
/
CSA Upon request
3
HA 4044
Designation Symbol Interposition Designation Symbol Interposition
Z11
H11
C11
P11
Y11
L21
C21
B11
R11
R21
A51
H51
H11
P51
C51
Y51
B51
Z51
C11
X11
J15
J75
Technical Data
Valve size mm (US) 10 (D 05)
Maximum flow L/min (GPM) see p-Q characteristics
Maximum operating pressure at ports P, A, B bar (PSI) 350 (5076)
Maximum operating pressure at port T bar (PSI) 210 (3050)
Pressure drop bar (PSI) see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range (NBR / Viton) °C (°F ) -30 ... +80 (-22 ... +176) / -20 ... +80 (-4 ... +176 )
Ambient temperature max. °C (°F ) +50 (+122)
Viscosity range mm
2
/s (SUS) 20 ... 400 ( 98 ... 1840)
Maximum degree of fluid contamination
Class 18/15 to ISO 4406. A filter with a retention
rate b
10
³ 75 is recommended.
Maximum allowable voltage variation % AC: ±10 DC: ±10
Maximum switching frequency 1/h 15 000
Switching time, ON; at n = 32 mm
2
/s (156 SUS ) ms AC: 50 ... 330 DC: 50 ... 120
Switching time, OFF; at n =32 mm
2
/s (156 SUS) ms AC: 100 ... 300 DC: 30 ... 90
Duty cycle % 100
Service life cycles 10
7
Enclosure type to EN 60529 IP 65
Weight - valve with 1 solenoid
- valve with 2 solenoids
kg (lbs)
3.9 (8.60)
5.4 (11.90)
Mounting position unrestricted
Spool Symbols
4
HA 4044
P-A P-B A-T B-T P-T
Z111122
Z51 1 2
H1111221
H51 1 2 1
P111122
P51 1 2
Y111122
Y51 1 2
C1143451
C51 4 5 1
R111122
X111122
B111122
B51 1 2
L2111122
R211113
J151223
J75 1 1
A51 1 1
C2166664
(725)
(1450)
(2176)
(2901)
(3626)
(4351)
(5076)
100
150
200
250
300
350
50
0
(725)
(1450)
(2176)
(2901)
(3626)
(4351)
(5076)
100
150
200
250
300
350
50
0
20 40 60 80 100 120 140
(5.3) (10.6) (15.9) (21.1) (26.4) (31.7) (37.0)
20 40 60 80 100 120 140
(5.3) (10.6) (15.9) (21.1) (26.4) (31.7) (37.0)
1
2
7
9
3
4
56
8
(145)
(174)
(203)
(231)
(261)
(290)
(304)
12
14
16
18
20
22
20 40 60 80 100 120 140
(5.3) (10.6) (15.9) (21.1) (26.4) (31.7) (37.0)
0
2
4
6
8
10
(29)
(58)
(87)
(116)
6
5
4
3
2
1
Flow Q [L/min (GPM)]
Flow Q [L/min (GPM)]
Pressure drop Dp [bar (PSI)]
Z11 Z51 H11 H51 P11 P51 Y11 Y51 C11 C51 R11 X11 B11 B51 L21 R21 J15 J75 A51 C21
11111155332244726689
p-Q Characteristics Measured at n = 32 mm
2
/s (156 SUS)
Operating limits for maximum hydraulic power transferred by the directional valve. For respective spool type - see spool
symbols.The power curves hold true for symmetrical valve flows (e.g. flows in directions P-A and B-T are identical). In case
of an asymmetric flow, the power curves can lie substantially lower. In such cases we highly recommend to consult the
respective power curve with the valve manufacture.
Dp-Q Characteristics Measured at n = 32 mm
2
/s (156 SUS)
Pressure drop Dp related to flow rate.
Flow Q[L/min (GPM)]
Operating pressure p [bar (PSI)]
Operating pressure p [bar (PSI)]
531
7
3
6
9
4
15.45 (0.608)
106 (4.173)
62 (2.440)
35 (1.377)
hexagon 5 A/F
70 (2.756)
118.5 (4.665)
122 (4.803)
96 (3.78)
59.9 (2.358)
~68.2 (2.685)
46 (1.811)
7/8"-16UN-2A
16 (0.63)
6.6 (0.26)
10.5 (0.413)
30 (1.181)
8.5 (0.334)
((220.5) (8.681))
3.2 (0.126)
16.7 (0.657)
27 (1.063)
50.8 (2)
54 (2.126)
13.5 (0.531)
24.6 (0.969)
39.7 (1.563)
46 (1.811)
Æ
11 (0.433)
106 (4.173) 106 (4.173)
hexagon 10 A/F
hexagon 36 A/F
Æ
106 (4.173)
106 (4.173)
hexagon 32 A/F
106 (4.173)
8.5 (0.334)
((220.5) (8.681))
37.3 (1.468)
ab
a
b
ab
a
b
8
Æ
2
5
HA 4044
Valve with one solenoid a
Functional symbols R11, R21,
Y51, C51, Z51, H51,
Valve with one solenoid b
Functional symbols C11, H11
1 Solenoid a (Nut torque 6Nm)
2 Solenoid b (Nut torque 6Nm)
3 Manual override
4 Name plate
5 Square ring 12.42 x 1.68 (5 pcs.)
supplied with valve
6 4 mounting holes
7 Retaining nut of the solenoid
8 Electrical connector
Valve with two solenoids
Required surface finish of
interface.
Valve Dimensions Dimensions in millimeters (inches)
6
HA 4044
Manual Override
Standard Rubber boot
No designation
Dimensions
Standard model of the manual override.
Standard retaining nut of the solenoid.
33 1.299()
50.5 1.988()
Manual override protectedby the rubber boot.
Type
N2
Dimensions
hexagon 14 A/F
T2 - Noozle Æ 0.157 (0.6)
The orifice extends the valve shifting time.
T3 - Throttle Screw
The control orifice allows for stepless adjustment
of the valve shifting time.
Soft Shifting Spool Options Delay Time
7
HA 4044
1 Solenoid coil
2 Mounting bolts
3 Nut with seal
4 Wiring box + connector
5 Seal kit
6 Terminal plate
7 Rubber cap with manual
override
5
1
3
7
4
2
6
Connector - US - Standard - ANSI/B93.55M
1 - green
2 - black
3 - white
1 - white
2 - red
3 - green
4 - orange
5 - black
solenoid a
solenoid b
solenoid a or b
Spare Parts
8
HA 4044
Solenoid Coil
Voltage rating Type Ordering number
01200 DC EW1 24174200
02400 DC EW1 24174300
10600 DC (120V/60Hz rectified) EW1 24174400
Solenoid Retaining Nut with Seal
Type of the nut Seal ring Ordering number
Standard nut O-ring 30 x 2 15900800
Nut with rubber boot 15900900
Electrical Connector, ANSI/B93.55M
Type Ordering number
3 PIN 24007300
5 PIN 24007400
Seal kit
Type
Dimensions
Ordering number
Square ring O-ring
Standard NBR70 12.42 x 1.68 (5 pcs.), 11,9 x 8,4 x 1 (1 pc.) 23.81 x 2.62 (2 pcs.), 1,8 x 1 (1 pc.) 15901000
Viton 12.42 x 1.68 (5 pcs.), 11,9 x 8,4 x 1 (1 pc.) 23.47 x 2.62 (2 pcs.), 1,8 x 1 (1 pc.) 15901100
Mounting bolts
Dimensions Tightening torque Ordering number
M6 x 40 DIN 912-10.9 (4 pcs.) 14+2 Nm (10.33+1.48 Ibf.ft) 15847700
Soft Shift Conversion Kit
T2 10 Nm (7.376 Ibf.ft) 15901200
T3 10 Nm (7.376 Ibf.ft) 15901300
Wiringbox
Type Ordering number
Wiring box without terminal plate 24175100
Terminal Plates
Type Ordering number
Terminal plate - basic design A+B 24173700
Terminal plate 12V DC -LED diodes A+B 24173800
Terminal plate 24V DC - LED diodes A+B 24173900
*Terminal plate 120V AC - rectifier A+B 24174000
*Terminal plate 120V AC - rectifier A+B and LED diodes A+B 24174100
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403 111
E-mail: info.cz@argo-hytos.com
www.argo-hytos.com
* CSA Upon request
In the case of directional control valves with two solenoids, any of the solenoids may be energized, but only after
powering off the other.
For directional control valves with other spool symbols as those shown in the table, please consult with the
manufacturer.
Other spool symbols on request.
The plastic packaging is recyclable.
The protective plate can be returned to manufacturer.
Mounting bolts, studs and DIN-connectors must be ordered separately.
Certified documentation is available per request.