1
The RPE4-10 directional control valves consist of
housing (1), control spool (5), centering springs (4) and
operating solenoids (2, 3).
The three-position directional control valves are fitted
with two solenoids and two springs. The two position
directional control valves have one solenoid and one
return spring.
The operating solenoids are DC solenoids and are
supplied through connectors (6, 7) without rectifiers. For
AC supply the solenoids are provided with rectifiers,
which are integrated directly into the connectors (6, 7) or
inside the coil.
By loosening the retaining nut (8), the solenoid can be
turned on its axis and locked in three positions 90° apart.
Provided that the pressure in T-port does not exceed
(25 bar), the spool of the valve can be shifted by manual
override (9).
The basic surface treatment of the valve housing (1) is
phosphate coated, the operating solenoids (2, 3) are
zinc coated.
HA 4039
11/2014
Size 10 · p
max
350 bar · Q
max
140 L/min
Directional Control Valves
Solenoid Operated
RPE4-10
Replaces
HA 4039 7/2009
A
B
a b
BA
   

q
4/3, 4/2 way directional control valves
q
Cylindrical DC solenoids with removable coils.
Electrical connectors can be rotated in three
positions 90° apart
q
Spool-position sensor optional
q
4 chamber spool - reducing
q
Push button manual override
q
Installation dimensions to DIN 24 340 /
ISO 4401 / CETOP RP121-H
q
Subplates see data sheet HA 0002
q
CSA Upon request
Functional Description
2
HA 4039
Ordering Code
RPE4-10 /
Nominal size
Number of operating positions
two positions 2
three positions 3
Directional Control Valve
Solenoid Operated
Seals
no designation standard (NBR)
V Viton (FPM)
Rated supply voltage of solenoids
(at the coil terminals)
12 V DC / 3.17 A
01200
24 V DC / 1.73 A 02400
205 V DC / 0.20 A 20500
230 V AC / 0.20 A / 50 (60) Hz 23050
120V AC / 60Hz* 12060
The AC coils correspond with E5 type.
Functional symbols
see the table functional symbols
Damping
no designation without damping
T2 with orifice
T3 with throttle screw
Manual override
no designation standard
N2 covered with rubber boot
Type of the solenoid coil
with for the electrical connector, EN 175301-803 E1
with integrated rectifier and for the electrical connector E5
EN 175301-803
Note: Connector of the position sensor is not supplied
(see ordering number on page 9)
FOR PREFERRED TYPES SEE BOLD TYPING IN ORDERING CODE, FUNCTIONAL SYMBOLS
AND TABLE OF PREFERRED TYPES ON PAGE 10
CSA Upon request
Sensing of the end position
no designation without s ensor
S1 normally-open sensor to 50bar
S2 normally-open sensor to 210bar
S4 normally-closed sensor to 50bar
3
HA 4039
Designation Symbol Interposition Designation Symbol Interposition
Y51
Z51
C51
C11
H11
R11
Y11
R21
Z11
Technical Data
Nominal size mm 10
Maximum flow L/min see p-Q characteristics
Maximum operating pressure at ports P, A, B bar 350
Maximum operating pressure at port T bar
50 for version S1, S4 and 210 for versinon S2
Pressure drop bar see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range (NBR / Viton) °C -30 ... +80 / -20 ... +80
Ambient temperature max. °C +50
Viscosity range mm
2
/s 20 ... 400
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Maximum allowable voltage variation % AC: ±10 DC: ±10
Maximum switching frequency 1/h 15 000
Switching time, ON; at n = 32 mm
2
/s ms AC: 50 ... 330 DC: 50 ...120
Switching time, OFF; at n = 32 mm
2
/s ms AC: 100 ... 300 DC: 30 ... 90
Duty cycle % 100
Service life cycles 10
7
Enclosure type to EN 60529 IP 65
Weight - valve with 1 solenoid
- valve with 2 solenoids
kg
3.9
5.4
Mounting position unrestricted
Functional Symbols
4
HA 4039
p-Q Characteristics Measured at n = 32 mm
2
/s
P-A P-B A-T B-T P-T
Z11 1 1 2 2
Z51 1 2
H11 1 1 2 2 1
H51 1 2 1
P11 1 1 2 2
P51 1 2
Y11 1 1 2 2
Y51 1 2
C11 4 3 4 5 1
C51 4 5 1
R11 1 1 2 2
X11 1 1 2 2
B11 1 1 2 2
B51 1 2
L21 1 1 1 2 2
R21 1 1 1 3
J15 1 1 2 3
J75 1 1
A51 1 1
C21 6 6 6 6 4
Flow Q [L/min]
Operating pressure p [bar]
Operating pressure p [bar]
Flow Q [L/min]
Flow Q [L/min]
Dp-Q Characteristics Measured at n = 32 mm
2
/s
Pressure drop Dp related to flow rate.
Pressure drop Dp [bar]
Z11 Z51 H11 H51 P11 P51 Y11 Y51 C11 C51 R11 X11 B11 B51 L21 R21 J15 J75 A51 C21
1 1 1 1 1 1 5 5 3 3 2 2 4 4 7 2 6 6 8 9
Operating limits for maximum hydraulic power transferred by the directional valve. For respective spool type - see
functional symbols. The power curves hold true for symmetrical valve flows (e.g. flows in directions P-A and B-T are identical).
In case of an asymmetric flow, the power curves can lie substantially lower. In such cases we highly recommend to consult the
respective power curve with the valve manufacture.
hexagon5
hexagon36
hexagon32
5
HA 4039
Valve Dimensions Dimensions in millimetres
Valve with one solenoid "a"
Functional symbols R11, R21,
Y51, C51, Z51, H51,
Valve with one solenoid "b"
Functional symbols C11, H11
1 Solenoid a
2 Solenoid b
3 Manual override
4 Name plate
5 Square ring 12,42 x 1,68 (5 pcs.)
supplied with valve
6 4 mounting holes
7 Retaining nut of the solenoid
8 Electrical connector, EN 175301-803
9 Throttle screw
10 Space reguired to remove connector
Valve with two solenoids
Required surface finish of
interface.
9
4
3
3
2
1
5
7
6
8
10
6
HA 4039
Type of the Solenoid Coil
E1
Solenoid coil with terminal for the electrical
connector, EN 175301-803
E5
Solenoid coil with integrated rectifier and
terminalfor electrical connector, EN 175301-803
Manual Override
Standard Rubber boot
Without designation
Dimensions
Description:
Standard model of the manual override.
Standard retaining nut of the solenoid.
Designation N2
Dimensions
Description:
Manual override protected by rubber boot.
41,5
53,5
46,5
58,5
33
50,5
hexagon 14 A/F
T2 - Noozle Æ 0,6
T3 - Throttle Screw
The control orifice allows for
stepless adjustment of
the valve shifting time.
The orifice extends
the valve shifting time.
Soft Shifting Spool Options Delay Time
Switching times
Switching time, on and off ms 120 ... 350
Switching times
Switching time, on and off ms 30 ... 2000
HA 4039
The proximity sensor transforms
the spool position into an
electrical step signal. It can be
used with directional control
valves with one or two solenoids.
106
106
~257
8,5
70
97
a (b) Sa (Sb)
36,5
113,5
~391
bSbSaa
BA
Technical Data of the Connector
Power supply voltage range V 10 ... 30 DC
Ambient temperature range °C -25 ... +80
Indication yellow LED
7
Two-Position Directional Control Valve
Dimensions in millimeters
Signal of solenoid a (b) Signal of sensor Sa (Sb) LED
S1, S2 - normally-open S4 - normally-closed S1, S2 S4
0 1 0 ON OFF
1 0 1 OFF ON
Technical Data of the Sensor S1, S4 S2
Rated power supply voltage V 24 DC
Power supply voltage range V 10 ... 30 DC
Rated current mA 200
Enclosure type of sensor to EN 60529 IP 67
Max. operating pressure bar 50 210
Switching frequency Hz 1000
Ambient temperature range °C -25 ... +80
Three-Position Directional Control Valve Dimensions in millimeters
Signal of solenoid Signal of sensor Sa (Sb) LED
S1, S2 - normally-open S4 - normally-closed S1, S2 S4
a b Sa Sb Sa Sb Sa - LED Sb - LED Sa - LED Sb - LED
0 0 1 1 0 0 ON ON OFF OFF
1 0 0 1 1 0 OFF ON ON OFF
Spool Position Sensor
S1, S2 - Circuit diagram of the
normally-open sensor
S4 - Circuit diagram of the
normally-closed sensor
Connector
2
PNP Sensor
Connector
PNP Sensor
8
HA 4039
1 Solenoid coil
2 Nut with seal
3 Electrical connector
4 Connector of position sensor with LED
5 Sensor
6 Seal kit
7 Mounting bolts
8 Rubber cap with manual override
Spare Parts
3
1
7
3 5
4
6
2 8
9
HA 4039
Connector of position sensor
Type designation Model Max. input voltage Ordering number
K02
connector of position
sensor with LED
10...30 V DC 17364800
S1 normally-open sensor 10...30 V DC 405111129213
S2 normally-open sensor 10...30 V DC 18838900
S4 normally-clsed sensor 10...30 V DC 20725300
Seal kit
Type
Dimensions
Ordering number
Square ring O-ring
Standard NBR70 12,42 x 1,68 (5 pcs.), 11,9 x 8,4 x 1 (1 pc.) 23,81 x 2,62 (2 pcs.), 1,8 x 1 (1 pc.) 15901000
Viton 12,42 x 1,68 (5 pcs.), 11,9 x 8,4 x 1 (1 pc.) 23,47 x 2,62 (2 pcs.), 1,8 x 1 (1 pc.) 15901100
Mounting bolts
Dimensions Tightening torque Ordering number
M6 x 40 DIN 912-10.9 (4 pcs.) 14+2 Nm 15847700
Soft Shift Conversion Kit
T2 10 Nm 15901200
T3 10 Nm 15901300
Solenoid coil
Type designation of the coil voltage
Type of the coil
E1 E5
Ordering number
01200 16195700
02400 16196100
20500 23898000
23050 16195100
12060 17366300
Solenoid retaining nut with seal
Type of the nut Seal ring Ordering number
Standard nut 30 x 2 15900800
Rubber cap with manual override 15900900
Electrical connector, EN 175301-803
Type
designation
Connector A grey Connector B black
Ordering number
K1 16202200 16202100
K5 16202600 16202500
K2 16202800 16202700
K3
16202400
16202300
K4 16203000 16202900
Electrical Connector, EN 175301-803
K1
Connector B (black)
without rectifier - M16x1.5
( bushing bore Æ 6-8 mm)
230 V AC/DC
Connector A (grey)
K5
Connector B (black)
without rectifier - M16x1.5
( bushing bore Æ 4-6 mm)
230 V AC/DC
Connector A (grey)
K2
Connector B (black) without rectifier with LED
and quenching diode - M16x1.5
( bushing bore Æ 6-8 mm)
12 ... 24 V DC
Connector A (grey)
K3
Connector B (black)
with rectifier - M16x1.5
( bushing bore Æ 6-8 mm)
230 V AC
Connector A (grey)
K4 Connector B (black)
with rectifier with LED
and quenching diode - M16x1.5
( bushing bore Æ 6-8 mm)
230 V AC
Recommended solenoid coils used with electrcial connector with rectifiers - type designation K3, K4
Rated supply source voltage
(permissible rated voltage variation ±10 %)
Type designation of the solenoid voltage
230 V AC / 0.17 A / 50 (60) Hz 20500
10
HA 4039
In the case of directional valves with two solenoids, any of the solenoids may be energized, but only after switching
off the other.
Directional valves with other functional symbols as those shown in the table, please consult with the manufacturer.
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
Mounting bolts M6 x 40 DIN 912-10.9 or studs must be ordered separately.
The technical information regarding the product presented in this catalogue is for descriptive purposes only.
It should not be construed in any case as a guaranteed representation of the product properties in the sense
of the law.
For RPEW4-10 with CSA only: Use supply wires suitable for at least 75°C.
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: sales.cz@argo-hytos.com
www.argo-hytos.com
Preffered Types
Type Ordering number Type Ordering number
RPE4-103Z11 15888500 RPE4-103Z11/02400E1 15889500
RPE4-102Z51 15892000 RPE4-102Z51/02400E1 15892300
RPE4-103C11 15888700 RPE4-103C11/02400E1 15890000
RPE4-102C51 15892100 RPE4-102C51/02400E1 15892500
RPE4-103H11 15889000 RPE4-103H11/02400E1 15892700
RPE4-103Y11 15888900 RPE4-103Y11/02400E1 15893100
RPE4-102R11 15889100 RPE4-102R11/02400E1 15890700
RPE4-102R21 15889200 RPE4-102R21/02400E1 15893400
RPE4-102Y51 15892200 RPE4-102Y51/02400E1 15893700
RPE4-103Z11/01200E1 15891600 RPE4-103Z11/23050E5 21867800
RPE4-102Z51/01200E1 15891200 RPE4-102Z51/23050E5 21868300
RPE4-103C11/01200E1 15891700 RPE4-103C11/23050E5 21868500
RPE4-102C51/01200E1 15891500 RPE4-102C51/23050E5 21868800
RPE4-103H11/01200E1 15891000 RPE4-103H11/23050E5 21862100
RPE4-103Y11/01200E1 15890400 RPE4-103Y11/23050E5 21868900
RPE4-102R11/01200E1 15891900 RPE4-102R11/23050E5 21869400
RPE4-102R21/01200E1 15891300 RPE4-102R21/23050E5 21869900
RPE4-102Y51/01200E1 15891400 RPE4-102Z51/23050E5 21870100