1
A B
P T
ab
A B
P T
a
A B
P T
b
q
4/3-, 4/2 way directional control valves
with solenoid control
q
Solenoids can be turned around their axis
to any position
q
Push button manual override
q
Possibility of vertical and horizontal assembly,
see data sheet HA 4057
Distributors of the RPEK1-03 type are the basic elements
for building blocks through horizontal and vertical
assembly. This catalogue describes the preparation of
the main unit, made up of two to eight distributors, by
horizontal assembly. The distributors controlling the
direction of the working fluid’s flow to the individual
appliances share common channels P and T. During the
circuit design it is always necessary to check if the flow
through the common channels covers the consumption
of all appliances in all phases of the hydraulic equipment
working cycle. Channels A, B outputs at the upper
surface of the body are provided with threads G1/4 (type
G), or SAE 9/16-18 (type S), or are prepared for vertical
assembly (type O) i.e. brought out onto a ground
surface. Channels P, T, A, B outlets on the side surfaces
of the body are prepared for horizontal assembly i.e.
brought out onto a ground surfaces or provided with a
sealing ring recess.
The individual distributor bodies are connected into a
compact block using three bolts. Fastening angles serve
to mount the block to the base with four screws.
An assembled block feed is provided by a plate with
connecting threads G3/8 in channels P, T. It is also
possible to use plate with a built-in pressure relief valve
to regulate the maximum pressure in the circuit.
Use data sheet No. HA 5027 to create more complex
assemblies with the use of the horizontal and vertical
assembly, while also using additional building elements.
The RPEK1-03 directional control valves consist of cast
iron housing (1), control spool (5) with two centering
springs (4) and operating solenoids (2, 3).
The three-position directional valves are fitted with two
solenoids, two-position directional valves have either
one solenoid.
*The operating solenoids are DC solenoids supplied
through connectors A, B (6, 7). For AC supply the
solenoids are provided with rectifiers, which are
integrated directly into the connectors A, B (6, 7). Tthe
connectors can be turned by 90° around . By loosening
the nut (8), the solenoid can be turned around its axis up
to 360°.
In the case of solenoid malfunction or power failure, the
spool of the valve can be repositioned by manual
override (9), provided the pressure in the T-port does not
exceed 25 bar.The standard design of the emergency
control may be additionally fitted with a pushbutton with
a rubber cover.
The basic surface treatment of the valve housing (1) is
phosphate coated and the solenoids (2, 3) are zinc
coated.
*Magnet coils are not included in the valve supply. The
coil types selected by the customer must be ordered
separately.
HA 4027
01/2012
Replaces
HA 4027 12/2007
Size 03 · p
max
250 bar (3625 PSI) · Q
max
20 L/min (5.28 GPM)
Directional Control Valves
Solenoid Operated
RPEK1-03
Type of
connection
"G", "S"
Type of connection
"O"
Functional Description
b
A
a
B
9 8 2 3 8 9
4 1 5 4
6
7
2
HA 4027
Nominal size
Solenoid Operated
Directional Control Valve
Ordering Code
Note: solenoid coil, electrical connector and manual override (N2) is not supplied as mounted on, must
be ordered separately (see ordering number on page 6; 7 and 10)
Type of connection
G1/4
G
SAE 9/16-18 S
without thread O
Design form
no designation standard
P1 through channels P, T; inlets A, B with sealing rings
Z1 one side inlets of channels P, T with sealing rings
Z3 one side inlets of channels P, T, A, B with sealing
rings
Number of valve positions
two positions
2
three positions 3
Functional symbols
see the table functional symbols
Seals
no designation NBR
V FPM (Viton)
Manual override *
no designation standard
*
The standard design of the manual override may be additionally
fitted with a pushbutton with a rubber cover (N2).
Nominal size 03
Maximum flow L/min (GPM) see p-Q characteristics
Maximum operating pressure at ports P, A, B bar (PSI) 250 (3625)
Maximum operating pressure at port T bar (PSI) 210 (3045)
Pressure drop bar (PSI) see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51 524
Fluid temperature range NBR °C (°F) -30 ... +80 (-22 ...+176)
Fluid temperature range FPM (Viton) °C (°F) -20 ... +80 (-4 .... +176)
Ambient temperature, max. °C (°F) up to +50 (+122)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98 .... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Maximum allowable voltage variation % AC: ± 10 DC: ± 10
Maximum switching frequency 1/h 15 000
Switching time, ON; at n = 32 mm
2
/s ms 30 ... 50
Switching time, OFF; at n = 32 mm
2
/s ms AC: 70 ... 100 DC: 30 ... 50
Duty cycle % 100
Service life cycles 10
7
Enclosure type to EN 60 529 see page 7
Weight
- valve with 1 solenoid
- valve with 2 solenoid
kg (Ib)
0.90 (1.98)
1,05 (2.32)
Mounting position unrestricted
Technical Data
RPEK1-03 /
3
HA 4027
Designation Symbol Interposition
Designation Symbol Interposition
1, 2, 3, 4, 5
1
2
4
5
3
1, 2, 3, 4, 5
0 5 10 15 20
(1.32) (2.64) (3.96) (5.28)
50
100
150
200
250
(725)
(1450)
(2176)
(2901)
(3626)
Z11 C11 H11 Y11 R11 R21 Y51 C51 Z51
P-A131122 3
P-B1311221 1
A-T1311221 1
B-T131122 3
P-T 2 2 2
0 5 10 15 20
(1.32) (2.64) (3.96) (5.28)
5
10
15
(725)
(1450)
(2176)
3
2
1
p-Q Characteristic Measured at n = 32 mm
2
/s (156 SUS)
Operating limits for maximum hydraulic power transferred by the directional valve.
Operating pressure p in bar [PSI]
Flow Q in l/min [GPM]
Dp-Q Characteristic Measured at n = 32 mm
2
/s (156 SUS)
Pressure drop Dpinbar[PSI]
Pressure drop Dp ralated to flow rate.
Functional Symbols
Z11 Z51 R11 R21 C11 C51 H11 Y11 Y51
111522344
Flow Q in l/min [GPM]
4
HA 4027
13(0.512)
(B)
P
T
30(1.181)
15,5(1.181)
15,5(1.181)
31(1.220)
(B)
(A)
T
P
T
P
T
a
b
a
b
B
24(0.945)
(15)
((0.591)) ((0.591))
2x 8Æ
(0.315)
(15)
24(0.945)
30,5(1.201)
61(2.401)
((0.520))
3x 6,4(0.252)
Æ
Æ
12,4(0.488)
1,4(0.055)
( 5,3(0.209))Æ
( 10,8(0.425))Æ
Æ
8(0.315)
7(0.275)
30(1.181)
10(0.394)
56(2.205)
33(1.299)
A
41,2(1.622)
44,4(1.748)
26(0.473)
12
(0.472)
(13,2)
(0.480)
12,2
THREAD
D
59(2.323)
179(7.047)
179(7.047)
123,5(4.862)
8
9
37 1
6 2 7 3
4 10 5
Valve with two solenoids
Valve with one solenoid "a"
Functional symbols R11, R21, Y51,
C51, Z51
Valve with one solenoid "b"
Functional symbols H11
1 Solenoid a *
2 Solenoid b *
3 Manual override
4 Name plate
5 Square ring 9,25 x 1,68 (2 pcs)
supplied with valve
6 3 mounting holes
7 Retaining nut of the solenoid
8 Electrical connector,
EN 1745301-803
9 Space required to remove
connector
10 Outlets A/B are only at the versions
P1, Z1; Z3, Seal 7,65x1,68
Required surface finish of
interface
* must be purchased separately (see page 7)
GS
THREAD G1/4 SAE6 - 9/16-18UNF
ÆD [mm] Æ20,9H13 Æ 25
+0,5
ÆD [in] 0.823 0.984
+0.020
A [mm (in)] 1(0.039) 0,5 (0.020)
Valve Dimensions Standard body version "G" , "S" Dimensions in millimeters (inches)
5
HA 4027
Æ
8,5(0.335)
3x 6,4(0.252)
Æ
24(0.945)
30,5(1.201)
61(2.401)
59(2.323)
179(7.047)
56(2.205)
33(1.299)
8(0.314)
(15)
P
T
12,4(0.488)
1,4(0.055)
30(1.181)
15,5(0.610)
31(1.220)
30(1.181)
( 10,8(0.425))
(
(B)
(A)
T
b
4,6(0.181)
26,4(1.039)
4,1(1.614)
15,5(0.610)
56,9(2.240)
1x45°
15(0.591)
12(0.472)
4xM5
B
123,5(4.862)
7(0.275)
P
T
P
T
(0.480)
24(0.945)
(15)
(0.591) (0.591)
8(0.315)
2x 8Æ
(0.315)
5,3
(0.209))
b
a
a
12,2
41,2(1.622)
44,4(1.748)
5,8
(0.228)
26(0.473)
12
(0.472)
(13,2)
((0.520))
8
27 33 7 1 6 10 4 5
9
1 Solenoid a *
2 Solenoid b *
3 Manual override
4 Name plate
5 Square ring 9,25 x 1,68 (2 pcs)
supplied with valve
6 3 mounting holes
7 Retaining nut of the solenoid
8 Electrical connector,
EN 1745301-803
9 Space required to remove connector
10 Outlets A/B are only at the versions
P1, Z1; Z3, Seal 7,65x1,68
* must be purchased separately (see page 7)
Required surface finish of
interface
Valve with two solenoids
Valve with one solenoid "a"
Functional symbols R11, R21, Y51,
C51, Z51
Valve with one solenoid "b"
Functional symbols H11
Valve Dimensions Standard body version "O" Dimensions in millimeters (inches)
6
HA 4027
Z3 - "G"( "S") Z3 - "O"
combination of options Z1 a P1
one side inlets of channels P, T, A, B with sealing rings
P1 - "G"( "S") P1 - "O"
hrough channels P, T; outlets A, B with sealing rings
Z1 - "G"( "S") Z1 - "O"
one side inlets of channels P, T with sealing rings (outlets A, B only on the upper surface)
Design form "G" ( "S"), "O"
Spare Seal kit
Type
Dimensions, number
Ordering nr.
Z1
Sealing - ring O-ring
Standard 9,25 x 1,68 NBR 70 (2 pcs.) 16 x 2 NBR 90 (2 pcs.) 15691300
Viton 9,25 x 1,78 (2 pcs.) 16 x 2 (2 pcs.) 15691400
Type
Dimensions, number
Ordering nr.
P1, Z3
Sealing - ring O-ring Sealing - ring
Standard 9,25 x 1,68 NBR 70 (2 pcs.) 16 x 2 NBR 90 (2 pcs.) 7,65 x 1,68 (2 pcs.) 28839800
Viton 9,25 x 1,78 (2 pcs.) 16 x 2 (2 pcs.) 7,65 x 1,78 (2 pcs.) 28840100
4xM5
for vertical
assembly
7
HA 4027
Manual override protected by rubber boot.
Kit must be purchased separately.
STANDARD
RUBBER BOOT
NO DESIGNATION
N2 Ordering number / Kit 29269100
29,5(1.161)
E3A, E4A
AMP Junior Timer
Protection degree IP65
Connector design
E1, E2
EN 175301-803-A
Protection degree IP65
39,3(1.55)
41(1.61)
20(0.79)
13,4(0.53)
30(1.18)
34,1(1.34)
41(1.61) 41(1.61)
30(1.18)
30(1.18)
13,4(0.53)
13,4(0.53)
Note:
* Coil version 205 are suitable for the rectified voltage of 230V /50Hz, Rectifier in coil included
Other designs available at request.
Standard model of the manual override.
Standard retaining nut of the solenoid.
18(0.709)
E12, E13
Deutsch DT04-2P
Protection degree IP67, IP69
KIT N2
Dimensions of Coils C14 Dimensions in millimeters (inches)
Manual Override Dimensions in millimeters (inches)
Coils C14B
Type Ordering number
Nominal
voltage
Nominal
current
Connector
12 VDC 1,83 A E1 - EN 175301-803-A C14B-01200E1-6,55NA 16210300
24 VDC 0,92 A E1 - EN 175301-803-A C14B-02400E1-26,2NA 16210400
205 V DC* 0,08 A E1 - EN 175301-803-A C14B-20500E1-2476NA 16210500
12 VDC 1,83 A E2 - E1 with quenching diode C14B-01200E2-6,55NA 24101600
24 VDC 0,92 A E2 - E1 with quenching diode C14B-02400E2-26,2NA 24101800
12 VDC 1,83 A E3A - AMP Junior Timer (2 pins; male) C14B-01200E3A-6,55NA 28822500
24 VDC 0,92 A E3A - AMP Junior Timer (2 pins; male) C14B-02400E3A-26,2NA 28686400
12 VDC 1,83 A E4A - E3A with quenching diode C14B-01200E4A-6,55NA 28822600
24 VDC 0,92 A E4A - E3A with quenching diode C14B-02400E4A-26,2NA 28822400
12 VDC 1,83 A E12 - Deutsch DT04-2P C14B-01200E12-6,55NA 29268200
24 VDC 0,92 A E12 - Deutsch DT04-2P C14B-02400E12-26,2NA 29268900
12 VDC 1,83 A E13 - E12 with quenching diode C14B-01200E13-6,55NA 29268800
24 VDC 0,92 A E13 - E12 with quenching diode C14B-02400E13-26,2NA 29269000
8
HA 4027
31(1.22)
5,8(0.23)
68(2.68)
35(1.38)
23(0.91)
27,5(1.08)
44,4(1.75)
23(0.91)
12.5(0.49)
a b
24 (0.94)
23 (0.91)
56(2.21)
68(2.68)
61(2.40)
24 (0.94)
2(0.08)
2(0.08)
14.5( )2(0.57
7,25( )2(0.29
48(1.89)
61(2.40)
6,4(0.25)
77(3.03)
38.5(1.52)
6,5(0.24)
2(0.08)
C
D
14( )2(0.55
24(2(0.94)
HB03-RPEK-06
Mounting Angle
T
P
Number of section
12345678
Dimension A [mm] 76(2.992) 107(4.212) 138(5.433) 169(6.653) 200(7.874) 231(9.094) 262(10.315) 293(11.535)
Dimension B [mm] 103(4.055) 134(5.275) 165(6.496) 196(7.716) 227(8.937) 258(10.157) 289(11.378) 320(12.598)
Dimension L [mm] 100(3.937) 133(5.236) 163(6.417) 194(7.638) 224(8.819) 256(10.079) 287(11.299) 320(12.598)
Dimensions
HB03-RPEK-08
Notte:
Example of simple block assembly with two to eight distributors, feeding plate and the end plate.
Block Assembly Dimensions in millimeters
Mounting Bolts M6 x L (see table)
Bolt torque 12 Nm
Connection
A and B - G1/4
Connection P and T - G3/8
M - G1/4
VERSION 1 - WITHOUT VALVE
9
HA 4027
24 (0.94)
23 (0.91)
56(2.21)
68(2.68)
61(2.40)
24 (0.94)
2(0.08)
2(0.08)
14.5( )2(0.57
7,25( )2(0.29
48(1.89)
61(2.40)
6,4(0.25)
6,5(0.24)
2(0.08)
A
14( )2(0.55
24(2(0.94)
42 (1.65)
77(3.03)
B
19 (0.75)
48(1.89)
31,5(1.24)
50(1.97)
15(0.59)
68(2.68)
33(1.30)
35(1.38)
ba
HB03-RPEK-MPT1
HB03-RPEK-08
Mounting Angle
M - G 1/4
Number of section
123456 7 8
Dimension A [mm] 87(3.425) 118(4.646) 149(5.866) 180(7.089) 211(8.307) 242(9.527) 273(10.748) 304(11.968)
Dimension B [mm] 114(4.488) 145(5.709) 176(6.929) 207(8.150) 238(9.370) 269(10.590) 300(11.811) 331(13.031)
Dimension L [mm] 60(2.362) 100(3.937) 133(5.236) 163(6.417) 194(7.638) 224(8.819) 256(10.079) 287(11.299)
Dimensions
Notte:
Example of simple block assembly with two to eight distributors, feeding block with a pressure relief valve and the end plate.
Block Assembly Dimensions in millimeters
Connection
A and B - G1/4
Screw M6 x 12
Screw torque 12 Nm
Mounting Bolts M6 x L (see table)
Bolt torque 12 Nm
Connection P and T - G3/8
VERSION 2 - WITH VALVE
10
HA 4027
B
a
b
A
1
1
2
3
4
1 Electrical connector
2 Solenoid coil - see coils table
3 Nut with seal
4 Seal kit
Spare Parts
Solenoid retaining nut with seal (Kit)
Type of the nut - Mu 3 Nm(2.21lbs-ft) Seal ring Ordering number
Standard nut 13 x 2 15691500
Manual Override N2
29269100
Electrical connector, EN 1745301-803
Type
designation
Model
Max. input
voltage
Connector A
grey
Connector B
black
Ordering number
K1
without rectifier - M16x1,5
bushing bore Æ 6-8 mm (0.236 - 0.315 in)
230 V AC/DC 16202200 16202100
K2
without rectifier with LED and quenching diode
M16x1,5
bushing bore Æ 6-8 mm (0.236 - 0.315 in)
12...24 V DC 16202800 16202700
K3
with rectifier - M16x1,5
bushing bore Æ 6-8 mm (0.236 - 0.315 in)
230 V AC 16202400 16202300
K4
with rectifier with LED and quenching diode - M16x1,5
bushing bore Æ 6-8 mm (0.236 - 0.315 in)
230 V AC 16203000 16202900
K5
without rectifier - M16x1,5
bushing bore Æ 4-6 mm (0.158 - 0.236 in)
230 V AC/DC 16202600 16202500
When the distributor contains two electromagnets any of the two electromagnets can be switched on only after the
other one switches off.
Distributors with other interconnections than those shown in the catalogue can be supplied on request.
The packaging foil can be recycled
The transport base plate can be returned to the manufacturer.
The mentioned data only serve to describe the product and in no case are to be understood in terms of law as
guaranteed characteristics.
Caution
Subject to alteration without!
ARGO-HYTOS s.r.o CZ - 543 15 Vrchlabí
tel.: 499 403111, fax: 499 403421
e-mail: sales.cz@argo-hytos.com
www.argo-hytos.com
Mounting Angle Tightening torque
Ordering number
Kit
Mounting Angle (1 pc.)
12 Nm (8.85Ibf-ft) 28799600
Bold M6 x 12 (2 pcs.)
Washer 6 (2 pcs.)
Spare Seal kit
see side 6
Coils table C14B
see side 7