1
Functional Description
q
Solenoid pilot operated directional valves (RNEH)
q
Hydraulic pilot operated directional valves (RNH)
q
Small energy input
q
Manual overrides optional
(only for RNEH)
q
Installation dimensions to DIN 24 340 /
ISO 4401 / CETOP RP121-H
The RNEH solenoid operated - hydropiloted valves are
consisting of an RPE3-06 type solenoid operated
directional control valve (see data sheet HA 4010) that
operates a 4-way hydropiloted control valve with a
connection surface in accordance with the ISO 4401
standards. They are available in various configurations
and spool types.
The pilot and the drain connections can be made internal
or external by inserting or removing the accordant
threaded plugs located in the main directional control
valve.
A wide range of configurations and different solenoid
operated - hydropiloted directional control valve spool
positions are available:
4-way, 3-position directional control valve, with two
solenoids; positioning of the spool in center position is
obtained with centering springs.
4-way, 2-position directional valve, with one solenoid
and one return spring or two solenoids and detent of the
spool position.
The basic surface treatment of the valve housing is
phosphate coated and the solenoids are zinc coated.
HA 4024
7/2015
Replaces
HA 4024 6/2012
Size 25 (D 08) · 320 bar (4600 PSI) · 600 L/min (159 GPM)
4/2 and 4/3 Way Directional
Control Valves Pilot Operated
RNEH4-25
2
HA 4024
RN 4-25 / / /33- /
Type of control
electrohydraulically operated
EH
hydraulically operated H
Design series
Directional Control
Valve Pilot Operated
Seals
no designation NBR
V FPM (Viton)
Number of operating positions
two positions
2
three positions 3
Manual overide
no designation standard
N1 covered with retaining nut
N2 covered with rubber boot
Rated supply voltage of solenoids *
(at the coil terminals)
01200 12 V DC / 2.72 A
02400 24 V DC / 1.29 A
12060 120 V AC / 0.35 A / 50 (60) Hz
23050 230 V AC / 0.17 A / 50 (60) Hz
The AC coils correspond with E5 type.
* Other voltages per request.
Series number
Piloting
if not required no designation
external piloting (see note herebelow)
E
Functional symbols
see the table Functional Symbols
Controls
if not required no designation
main spool shifting speed control
D
shifting speed control, with orifice (0.8 mm)
in port P of solenoid pilot valve
PF
Check valve incorporated on P-line
no designation if not required
C3 with check valve (see pages 5, 7)
Drain
no designation external drain which is recommended
when the valve is used
with back pressure on the outlet
I internal drain
Ordering Code
Note:
Piloting must always be external for valves with the H11 type pilot valve (available on request). Also valve must have external
piloting for spools with P and T connected in the center position. Internal piloting is possible only with a C3 version valve (see
page 7), or by installing a check valve with a setting of min. 5 bar on the outlet line. In this case the valve must have external
drainage.
Piloting must always be external for valves with the RNH type hydraulic control valve (available on request).
Type of solenoid coil
E1 with terminal for the connector*
E2 with integrated quenching diode
and terminal for the connector*
E5 with integrated rectifier and terminal
for the connector*
* from EN 1745301-803
Valve size 25
(D 08)
3
HA 4024
Two positions with return spring Two positions with return spring
R51 X51
R52 X52
Two positions with mechanical detent on pilot valve
J17
J27
Besides the diagrams shown, which are the most frequently used, other special versions are available:
consult our technical department for their identification, feasibility and operating limits.
Technical Data
Valve size mm (US) 25 (D 08)
Maximum flow rate from port P to A, B, T L/min (GPM ) 600 (159)
Max. operating pressure
ports P, A, B
port T
port T (external drain version)
bar (PSI)
320 (4600)
210 (3000)
250 (3600)
Pressure drop bar (PSI) see Pressure Drop Dp-Q
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51 524
Fluid temperature range for NBR seals °C (°F ) -30 ... +80 (-22 ... +176)
Fluid temperature range for FPM seals °C (°F ) -20 ... +80 (-4 ... +176)
Ambient temperature max. °C (°F ) +50 (+122)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Service life cycles 10
7
Enclosure type to EN 60 529 IP 65
Weight - RNEH4-252
- RNEH4-253
kg (Ibs)
15 (33)
15.6 (34.3)
Functional Symbols
Symbols are referred to the solenoid valve RNEH. For the hydraulic control version RNH please verify the connection
scheme (see page 7).
Three positions with spring centering Three positions with spring centering
Z11 H11
Y11 C11
4
HA 4024
Performance Characteristic
Pressures in bar (PSI) MIN. MAX.
Pilot pressure 5 (72.5) 210 (3045)
Pressure on line T with internal drain - 140 (2030)
Pressure on line T with external drain - 250 (3625)
Maximum flow rates in L/min (GPM)
PRESSURES
210 bar (3045 PSI ) 320 bar (4640 PSI )
Spool type C11 500 (133) 450 (119)
All other spools 600 (159) 500 (133)
Pressure Drop Dp-Q Measured at n = 32 mm
2
/s (156 SUS) and t = 40 °C (104 °F)
Spool type Spool position
Connections
P - A P - B A - T B - T P - T
Curves on graph
Z11
Energized 1
123
H11
De-energized 6*
Energized 5512
Y11
De-energized 4
·
Energized 1112
C11
De-energized 6
Energized 6634
R51, R52,
X51, X52
De-energized 1 1
Energized 1 2
J17, J27
Energized 1123
* A-B blocked
·
B blocked ° A blocked
Pressure drop Dp related to flow rate.
Flow Q [L/min (GPM)]
Pressure drop Dp [bar (PSI)]
5
HA 4024
Pilot and Drain
The RNEH valves are available with pilot and drain, both internal and external. The version with external drain allows
for a higher back pressure on the outlet.
Type of valve
Plug assembly
XY
RNEH4-25**/*
Internal pilot and external drain NO* YES
RNEH4-25**/*I
Internal pilot and internal drain NO* NO
RNEH4-25**/*E
External pilot and external drain YES YES
RNEH4-25**/*EI
External pilot and internal drain YES NO
X: plug M6 x 8 for external pilot
Y: plug M6 x 8 for external drain
* C3 version is available only with internal pilot.
Electrical Features
DC solenoid AC solenoid
Max. allowable voltage variation % -10 ... +6 ±10
Max. switching frequency 1/h 8 000
Switching times ±10 %, energizing (two position) ms 75 60
Switching times ±10 %, de-energizing (two position) ms 90 90
Switching times ±10 %, energizing (three position) ms 55 45
Switching times ±10 %, de-energizing (three position) ms 60 60
Duty cycle % 100
Enclosure type to EN 60 529 IP 65
Solenoids
The operating solenoids are DC solenoids. For AC supply the solenoids are provided with rectifier which are integrated in the
EN connector socket as part of the solenoid. The connectors can be turned by 90°. By loosening the nut, the solenoids can be
turned or replaced without interfering with any seals of the valve.
In the case of solenoid malfunction or power failure, the spool of the valve can be shifted by manual override, provided the
pressure in T-port does not exceed 25 bar.
The values indicated refer to a solenoid valve operating with piloting pressure 100 bar, with mineral oil at a temperature of
40 °C, a viscosity of 32 mm
2
/s and with PA and BT connections. The switch on times are obtained from the time the spool
switches over. The switch off times are measured at the time pressure variation occurs in the line.
Y: plug M6 x 8 for external drain
with version C3
6
HA 4024
1
2
2
3
45
ab
Required surface finish of
interface
Single valve fastening: 6 bolts M12 x 60 *
Bolt torque: 69 Nm (50.9 ft-lbf) - bolts A 8.8
Threads of mounting holes: M12 x 20 (1/2-13 UNC)
Seal rings: 4 O-rings 29,82 x 2,62
2 O-rings 20,29 x 2,62
Installation dimensions
1 Mounting surface with seal rings
2 Manual override
3 Space required to remove coil
4 Electrical connector
(must be ordered separately)
5 Space required to remove connector
Valve Dimensions Dimensions in millimetres (inches)
RNEH4-252, RNEH4-253
* Bolts is not supplied
7
HA 4024
Solenoid control: RNEH
The valve is supplied with a pilot solenoid
valve type RPE3-06.
Controls
Control of the main spool shifting speed: D
By placing a 2VS3-06 type double flow control valve between the pilot solenoid valve and the hydropiloted valve, the piloted
flow rate can be controlled and therefore the shifting speed can be varied. Add the letter D to the identification code to
request this device.
Type of Command
Manual Override
Whenever the solenoid valve installation may involve exposure to atmospheric agents or be used in tropical climates,
the manual override, boot protection is recommended. Add the suffix N1or N2 to request this device.
Electrical Connector
The solenoid valves are never supplied with connector. Connectors must be ordered separately.
Special Configurations C3
Check valve incorporated on line P: C3
Valve RNEH is available upon request with check valve incorporated on line
P. This is particularly useful to obtain the necessary piloting pressure when
the main control valve, in the rest position, has line P connected to the T
outlet. The cracking pressure is 5 bar. Add C3 to the identification code for
this request.
C3 version is available only with internal pilot.
TP
b
a
AB
Hydraulic control: RNH
The valve is supplied with a cross-connection
cover-plate.
X and Y connections are used for the hydraulic control
of the valve.
RNH4-253
RNH4-252
RNH4-252
8
HA 4024
Installation
Configurations with centering and recall springs can be mounted in any position; type J17, J27 valves - without springs and
with mechanical retention must be mounted with the longitudinal axis horizontal. Valve fastening takes place by means of
screws or tie rods, placing the valve on a flat surface, with values of planarity and smoothness that are equal to or better
than those indicated in the drawing. If the minimum values of planarity or smoothness are not met, fluid leakages between
valve and mounting surface can easily occur.
Service valve without range stated parameter consultation with manufacturer.
Detaile information at control vavle - see data sheet RPE3-06, HA 4010
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
The technical information regarding the product presented in this data sheet is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.
Spare Parts
Seal kit
Design
Dimensions, number
Ordering
number
O-ring Square ring Back-up ring
Head vavle
size 25
(D 08)
Standard - NBR
29,82 x 2,62 (4 pcs.)
--
21850300
20,29 x 2,62 (2 pcs.)
40,94 x 2,62 (2 pcs.)
34,59 x 2,62* (1 pc.)
Viton
29,82 x 2.62 (4 pcs.)
21850400
20.29 x 2,62 (2 pcs.)
40,94 x 2,62 (2 pcs.)
34,59 x 2,62* (1 pc.)
Throttle valve
2VS3-06-CS
type number
15929600
Standard - NBR
18 x 2,65 (2 pcs.) 9,25 x 1,68 (4 pcs.) 6,73 x 9,43 x 1,14 (2 pcs.)
15936300
6,9 x 1,8 (2 pcs.)
-
17,83 x 22,19 x 1,14 (2 pcs.)
Viton
17,12 x 2,62 (2 pcs.) 9,43 x 6.73 x 1,14 (2 pcs.)
159366009,25 x 1,78 (4 pcs.) 17,83 x 22,19 x 1,14 (2 pcs.)
6,75 x 1,78 (2 pcs.) -
Control valve see data sheet ARGO-HYTOS - RPE3-06
Mounting bolt
Dimensions, number Tightening torque
Ordering
number
Fixation of
extension
of valve
Bolt M5 x 45
DIN 912-10.9
(4 pcs.)
8.9 Nm
(6.6 ft-lbf)
15845100
Bolt M5 x 98 - 8G
(4 pcs.) 16103700
Nut M5
Other
Design
Cover plate
PA, BT 15934200
PB, TA 15933700
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
tel.: +420-499-403 111
e-mail: info.cz@argo-hytos.com
www.argo-hytos.com