Functional Description
The RNEH solenoid operated - hydropiloted valves are
consisting of an RPE3-06 type solenoid operated
directional control valve (see data sheet HA 4010) that
operates a 4-way hydropiloted control valve with a
connection surface in accordance with the ISO 4401
standards. They are available in various configurations
and spool types.
The pilot and the drain connections can be made internal
or external by inserting or removing the accordant
threaded plugs located in the main directional control
valve.
A wide range of configurations and different solenoid
operated - hydropiloted directional control valve spool
positions are available:
4-way, 3-position directional control valve, with two
solenoids; positioning of the spool in center position is
obtained with centering springs.
4-way, 2-position directional valve, with one solenoid
and one return spring or two solenoids and detent of the
spool position.
The basic surface treatment of the valve housing is
phosphate coated and the solenoids are zinc coated.
HA 4023
7/2015
Replaces
HA 4023 9/2014
Size 16 (D 07) · 350/420 bar (5080/6090 PSI) · 300 L/min (80 GPM)
4/2 and 4/3 Way Directional
Control Valves Pilot Operated
RNEH5-16
q
Solenoid pilot operated directional valves (RNEH)
q
Hydraulic pilot operated directional valves (RNH)
q
Small energy input
q
Manual overrides optional
(only for RNEH)
q
Installation dimensions to DIN 24 340 /
ISO 4401 / CETOP RP121-H
2
HA 4023
Type of control
electrohydraulically operated
EH
hydraulically operated H
Directional Control
Valve Pilot Operated
Valve size
Number of operating positions
two positions
2
three positions 3
Rated supply voltage of solenoids *
(at the coil terminals)
01200 12 V DC / 2.72 A
02400 24 V DC / 1.29 A
12060 120 V AC / 0.35 A / 50 (60) Hz
23050 230 V AC / 0.17 A / 50 (60) Hz
The AC coils correspond with E5 type.
* Other voltages per request.
Type of solenoid coil
E1 with terminal for the connector*
E2 with integrated quenching diode
and terminal for the connector*
E5 with integrated rectifier and terminal
for the connector*
Piloting
Internal no designation
External
E
Internal with pressure reducing valve Z
30 bar fix setting
Functional symbols
see the table functional symbols
Ordering Code
Note:
for spools H11 and C11 use check valve in P line – see option C3 page 7
Piloting must always be external for valves with the RNH type hydraulic control valve.
* from EN 1745301-803-A
Drain
no designation External
I Internal
Design series
standard 350 bar
5
high pressure version 420 bar
(5H is not available for spool C11)
5H
Manual override
no designation Standard
N1 covered with retaining nut
N2 covered with rubber boot
Check valve incorporated in P-line
no designation if not required
C3 with check valve (see page 3)
see HA 4010 for other pilot valve options
Seals
no designation NBR
V FPM (Viton)
Controls
f not required no designation
main spool stroke limiter
C
main spool shifting speed control D
shifting speed control, with orifice (0.8 mm)
in port P of solenoid pilot valve
PF
RN -16 / / / /
3
HA 4023
Technical Data
Valve type RN*5-16 RN*5H-16
Valve size mm (US) 16 (D 07)
Maximum flow rate from port P to A, B, T L/min (GPM ) 300 (80)
Max. operating pressure
ports P, A, B
- on line T with external drainage
- on line T with internal drainage)
bar (PSI)
350 (5800)
210 (3000)
140 (2030)
420 (6090)
350 (5800)
140 (2030)
Minimum pilot pressure bar (PSI 12 (174) 12 (174)
Maximum pilot pressure bar (PSI) 210 ( 3043)* 350 (5800)*
Pressure drop bar (PSI) see Pressure Drop Dp-Q
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for NBR seals °C (°F ) -30 ... +80 (-22 ... +176)
Fluid temperature range for FPM seals °C (°F ) -20 ... +80 (-4 ... +176)
Ambient temperature max. °C (°F ) +50 (+122)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Service life cycles 10
7
Enclosure type to EN 60529 IP 65
Weigt - RNH5-16
- RNEH5-162
- RNEH5-163
kg (Ibs)
6,6 (14.5)
8,2 (18)
8,8 (19.4)
*) for higher system pressure use option Z
Functional Symbols
Symbols are referred to the solenoid valve RNEH. For the hydraulic control version RNH please verify the connection
scheme (see page 7).
Three positions with spring centering Three positions with spring centering
Z11 H11
Y11 C11
Two positions with return spring Two positions with return spring
X11 R11
X21 R21
Two positions with mechanical detent on pilot valve
J15
J27
Besides the diagrams shown, which are the most frequently used, other special versions are available:
consult our technical department for their identification, feasibility and operating limits.
4
HA 4023
Dp-Q Characteristic Measured at n = 32 mm
2
/s (156 SUS) and t = 40 °C (104 °F)
200 250 300
(58)
(87)
(29)
(116)
(145)
0
50
100
4
6
2
8
10
150
(52.8)
(66.0)
(13.2) (39.6)(26.4) (79.3)
4
3
5
1
2
Pressure drop Dp [bar(PSI)]
200 250 300
0
50
100
6
2
150
(52.8)
(66.0)
(13.2) (39.6)(26.4) (79.3)
4
10
8
14
12
(58)
(87)
(24)
(174)
(203)
(116)
(145)
Spool type Spool position
P - A P - B A - T B - T P - T
Curves on graph
Z11 Energized 1 1 3 4
H11
Energized 1 1 4 4
De-energized 2
Y11
Energized 1 1 4 4
De-energized 4 4
C11
Energized 2 2 4 5
De-energized 4
R11, R21 1 1 3 4
X11, X21 1 1 4 4
J15, J27 1 1 3 4
200 250 300
0
50
100
150
50
150
(52.8)
(66.0)
(13.2) (39.6)(26.4) (79.3)
1
2
100
250
200
250
200
(1450)
(2176)
(725)
(4351)
(5076)
(2901)
(3626)
Q Characteristic Measured at n = 32 mm
2
/s (156 SUS) and t = 40 °C (104 °F)1
Spool type
P - A P - B
Curves on graph
Z11 1 1
H11 1 1
Y11 1 1
C11 2 2
R11, R21 1 1
X11, X21 1 1
J15, J27 1 1
Flow Q [L/min(GPM)]
p [bar(PSI)]
Operating limits
Check valve - Pressure Drop Dp-Q
This curve refers to the pressure drop (body part only)
with option C3 (check valve in P port). This pressure
drop must be added to the pressure drop of the
reference spool
Spool types - Pressure Drop Dp-Q
Flow Q [L/min(GPM)]
Flow Q [L/min(GPM)]
5
HA 4023
Electrical Features
DC solenoid AC solenoid
Max. allowable voltage variation % ±10 ±10
Max. switching frequency 1/h 10 000
Switching times ±10 %, energizing (two position) ms 70 60
Switching times ±10 %, de-energizing (two position) ms 80 80
Switching times ±10 %, energizing (three position) ms 50 80
Switching times ±10 %, de-energizing (three position) ms 60 60
Duty cycle % 100
Enclosure type to EN 60 529 IP 65
Solenoids
The operating solenoids are DC solenoids. For AC supply the solenoids are provided with rectifier which are integrated in the DIN
connector socket as part of the solenoid. The connectors can be turned by 90°. By loosening the nut, the solenoids can be turned
or replaced without interfering with any seals of the valve. In the case of solenoid malfunction or power failure, the spool of the
valve can be shifted by manual override, provided the pressure in T-port does not exceed 25 bar.
The values indicated refer to a solenoid valve operating with piloting pressure 100 bar, viscosity of 32 mm
2
/s and with
PA and BT connections. The switch on times are obtained from the time the spool switches over. The switch off times are
measured at the time pressure variation occurs in the line.
X: plug M6 x 8 for external pilot
Y: plug M6 x 8 for external drain
Pilot and Drain
.
Type of valve
Plug assembly
XY
RNEH5-16**/*
Internal pilot and external drain NO YES
RNEH5-16**/*I
Internal pilot and internal drain NO NO
RNEH5-16**/*E
External pilot and external drain YES YES
RNEH5-16**/*EI
External pilot and internal drain YES NO
Check valve incorporated on line P: C3
Valve RNEH is available upon request with check valve incorporated on line P. This is
particularly useful to obtain the necessary piloting pressure when the main control
valve, in the rest position, has line P connected to the T outlet. The cracking pressure is
5 bar. Add C3 to the identification code for this request.
Special Configurations C3
Always without X plug
C3
The RNEH valves are available with pilot and drain, both internal and external. The version with external drain allows
for a higher back pressure on the outlet
6
HA 4023
215 8.47()75 2.95()
45 [1.77]
97 [3.82]
154 [6.06]
125 [4.92]
184 [7.24]
201 [7.91]
3 [0.12]
4 [0.16]
92 [ ]3.62
50 [1.97]
40 [1.57]
190 [7.48]
12 [0.47]
1
2
2
3
45
a
b
Valve Dimensions Dimensions in millimeters (inches)
RNEH5-162, RNEH5-163
Single valve fastening: 4 bolts M10 x 60 *
2 bolts M6 x 60 *
Bolt torque: M10 x 60: 40 Nm (29.5 ft-lbs) - bolts A 8.8 67 Nm(49.5 ft-lbs) - bolts A 12.9
M6 x 60: 8 Nm (5.9 ft-lbs) - bolts A 8.8 14 Nm(10.3 ft-lbs) - bolts A 12.9
Threads of mounting holes: M6 x 18; M10 x 18
Seal rings: 4 O-rings type 22.22 x 2.62
2 O-rings type 10.82 x 1.78
1 Mounting surface with seal rings
2 Manual override
3 Space required to remove coil
4 Electrical connector
(must be ordered separately)
5 Space required to remove connector
Required surface finish of
interface
* Bolts is not supplied
7
HA 4023
Type of Command
90 (3.54)
17 (0.67)
215 (8.46)
230 controls or pilotting
270 for both - option
DZ
D+Z
(9.05) for
(10.63)
Solenoid control: RNEH
The valve is supplied with a pilot solenoid valve type RPE3-06.
Controls and pilotting
Control of the main spool shifting speed: D
By placing a 2VS3-06 type double flow control valve
between the pilot solenoid valve and the hydropiloted valve,
the piloted flow rate can be controlled and therefore the
shifting speed can be varied. Add the letter D to the
identification code to request this device.
Hydraulic control: RNH
The valve is supplied with a cross-connection
cover-plate.
X and Y connections are used for the hydraulic control
of the valve.
RNH5-163
RNH5-162R*
RNH5-162X*
RNEH5
RNH5
Main spool stroke limiter: C
Stroke limiters reduce flow through the valve.
Pilot pressure reducing valve - 30 bar fix setting: Z
Instead of option D or together with option D can be used
option Z.
Manual Override
Whenever the solenoid valve installation may involve exposure to atmospheric agents or be used in tropical climates,
the manual override, boot protection is recommended. Add the suffix N1 or N2 to request this device.
Electrical Connector
The solenoid valves are never supplied with connector. Connectors must be ordered separately.
8
HA 4023
Installation
Configurations with centering and recall springs can be mounted in any position; type J17, J27 valves - without springs and
with mechanical retention must be mounted with the longitudinal axis horizontal. Valve fastening takes place by means of
screws or tie rods, placing the valve on a flat surface, with values of planarity and smoothness that are equal to or better
than those indicated in the drawing. If the minimum values of planarity or smoothness are not met, fluid leakages between
valve and mounting surface can easily occur.
Service valve without range stated parameter consultation with manufacturer.
Detaile information at control vavle - see data sheet RPE3-06, HA 4010
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
The technical information regarding the product presented in this data sheet is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.
Spare Parts
Seal kit
Design
Dimensions, number
Ordering
number
O-ring Square ring Back-up ring
Head valve
size 16 (D 07)
Standard - NBR
22.22 x 2.62 (4 pcs.)
--
3254970010.82 x 1.78 (2 pcs.)
37.69 x 3.53 (2 pcs.)
Viton
22.22 x 2.62 (4 pcs.)
3254980010.82 x 1.78 (2 pcs.)
37.69 x 3.53 (2 pcs.)
Throttle valve
2VS3-06-CS
type number
15929600
Standard - NBR
18 x 2.65 (2 pcs.) 9.25 x 1.68 (4 pcs.) 6.73 x 9.43 x 1.14 (2 pcs.)
15936300
6.9 x 1.8 (2 pcs.)
-
17.83 x 22.19 x 1.14 (2 pcs.)
Viton
17.12 x 2.62 (2 pcs.) 9.43 x 6.73 x 1.14 (2 pcs.)
159366009.25 x 1.78 (4 pcs.) 17.83 x 22.19 x 1.14 (2 pcs.)
6.75 x 1.78 (2 pcs.) -
Control valve see data sheet ARGO-HYTOS - HA 4010 - RPE3-06
Mounting bolt
Dimensions, number Tightening torque
Ordering
number
Fixation of
extension
of valve
Bolt M5 x 45
DIN 912-10.9
(4pcs.)
8.9 Nm
(6.6 ft-lbs)
15845100
Bolt M5 x 98 - 8G
(4 pcs.) 16103700
Nut M5
Other
Design
Cover plate
PA, BT 15934200
PB, TA 15933700
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí