1
Size 06 (D 03) · 350 bar(5076 PSI) · 80 L/min(21 GPM)
Hydraulic Operated Directional
Control Valves
The directional control valves are of modular design and
comprise a housing (1) with a cylidrical spool (2) and
one or two operating elements (3) consisting of
hydraulic pistons (4) and return spring (5).
Three-position directional valves are fitted with two
hydraulic operating elements and two centering
springs. Two-position directional valves have only one
hydraulic operating element and one springs.
The basic surface treatment of the valve housing is
phosphate.
AB
P
T
      
q
4/3, 4/2 way spool type directional valves
hydraulic operated
q
Installation dimensions to DIN 24 340 /
ISO 4401 / CETOP RP121-H
q
Connecting threads M10x1, G1/8
Functional Description
HA 4006
04/2011
RPH3-06
A B
P T
Replaces
HA 4006 12/2007
2
HA 4006
Ordering Code
RPH3-06 /
Functional symbols
see the table functional symbols
Nominal size
Hydraulic Operated Directional
Control Valve
Number of operating positions
two positions
three positions
2
3
Seals
no designation
V
NBR
FPM (Viton)
Model
1 Hydraulic
2 Pneumatic
Connecting threads
1
2
M10x1
G1/8
Spare Parts
Technical Data
Seal kit
Type Dimansions, number Ordering number
Standard NBR 9,25 x 1,68 NBR70 (4 pcs.) 17 x 1,8 (2 pcs.) 15845200
Viton 9,25 x 1,78 (4 pcs.) 17,17 x 1,78 (2 pcs.) 15845400
Mounting bolts
Dimensions, number Tightening torque Ordering number
M5 x 45 DIN 912-10.9 (4 pcs.) 8.9 Nm (6.6 ft-Ibf) 15845100
Valve size mm(US) 06
Maximum flow (according to pressure
and functional symbols)
L/min (GPM) see p-Q characteristics
Maximum operating pressure at ports P, A, B bar (PSI) 350 (5076)
Maximum operating pressure at port T bar (PSI) 160 (2321)
Minimum pilot pressure bar (PSI) 2 (29)
Maximum pilot pressure bar (PSI) 25 ( 362.6)
Pilot volume cm
3
(cu.in). 6,2 (0,378)
Pressure drop bar (PSI) see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for standard sealing (NBR) °C (°F) -30 ... +100 (-22 ... +21)
Fluid temperature range for Viton seals (FPM) °C (°F) -20 ... +120 (-4 ... +248)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Service life cycles 10
7
Weight valve with 1 actuator
valve with 2 actuators
kg (lbs)
1,8 ( 3.96)
2,5 (5.50)
Mounting position unrestricted
3
HA 4006
Three position directional valves RPH3-063
Type Symbol Crossover
Two position directional valves RPH3-062
Type Symbol Crossover
Operating pressure p [bar (PSI)]
Flow Q [L/min (GPM)]
Operating pressure Dp [bar (PSI)]
P-A P-B A-T B-T P-T
Z112233
C1144453
H1122223
P111133
Y112222
L212233
B112233
R112233
A51 2 2
P51 1 3
Y51 2 2
X112233
J152233
J75 2 2
p-Q Characteristics Measured at n = 32 mm
2
/s (156 SUS )
(5.28) (10.57) (15.85) (21.13)
(464)
(348)
(116)
(232)
Dp-Q Characteristics Measured at n = 32 mm
2
/s (156 SUS )
Z11 1
C11 2
H11 3
P11 1
Y11 1
L21 4
B11 1
R11 1
A51 1
P51 1
Y51 2
X11 1
J15 1
J75 1
Functional Symbols
Operating limits for maximum hydraulic power transferred by the directional valve. Measured by steering pressure
2 bar (29 PSI). For respective spool type - see Functional Symbols.
(2.64) (7.93) (13.21) (18.49) (23.77)
(725)
(1450)
(2176)
(2901)
(3626)
(4351)
(5076)
Flow Q [L/min (GPM)]
Pressure drop Dp related to flow rate.
4
HA 4006
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: sales.cz@argo-hytos.com
www.argo-hytos.com
Valve Dimensions Dimensions in millimeters (inches)
For applications outside the given parameters, please consult us.
Other for spool symbols on request.
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
Mounting screws M5 x 45 DIN 912-10.9 or bolts must be ordered separately.
The screws tightening torque is 8.9 Nm (6.6 ft-Ibs).
The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.
3
4
1
5
2
1 Operating element 1
2 Operating element 2
3 Name plate
4 Square ring 9.25 x 1.68 (4 pcs.)
supplied with each valve
5 4 mounting holes
Required surface finish of
interface