1
Functional Description
q
4/3-, 4/2-way spool type directional valves
hydraulic operated
q
Installation dimensions to DIN 24 340 /
ISO 4401 / CETOP RP121-H
q
Three-chamber valve
A
B
P
T
The directional control valves are of modular design and
comprise a housing (1) with a cylidrical spool (2) and
one or two operating elements (3) consisting of
hydraulic pistons (4) and return springs (5).
Three-position directional valves are fitted with two
hydraulic operating elements and two centering
springs. Two-position directional valves have only one
hydraulic operating element and one springs.
The basic surface treatment of valve is phosphate
coated.
AB
PT
      
HA 4005
04/2011
Size 06 (D 03) · 350 bar (5076 PSI) · 80 L/min (21 GPM)
Directional Control Valves
Hydraulically Operated
RPH2-06
Replaces
HA 4005 12/2007
2
HA 4005
RPH2-06 / -1
Spool symbols
see the table spool symbols
Valve size 06 (D 03)
Directional control valves
hydraulically operated
Number of operating positions
two positions
three positions
2
3
Seals
no designation
V
NBR
FPM (Viton)
Model
Connecting threads
1
2
3
M10x1
G1/8
7/16-20 UNF-2B,SAE-4
Ordering Code
Valve size mm (US) 06 (D 03)
Maximum flow (according to pressure
and functional symbols)
L/min (GPM) see p-Q characteristic
Maximum operating pressure at ports P, A, B bar (PSI) 350 (5076)
Maximum operating pressure at port T bar (PSI) 130 (1885)
Minimum pilot pressure bar (PSI) 30 (435) + pressure at port T
Maximum pilot pressure bar (PSI) 160 (2300)
Pilot volume cm
3
(cu.in.) 0,5(0.031)
Pressure drop bar (PSI) see Dp-Q characteristic
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for standard sealing (NBR) °C (°F) -30 ... +100 (-22 ... +212)
Fluid temperature range for Viton seals (FPM) °C (°F) -20 ... +120 (-4 ... +248)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Service life cycles 10
7
Weight valve with 1 actuatop
valve with 2 actuators
kg (lbs)
1,8 (3.96)
2,5 (5.50)
Mounting position unrestricted
Technical Data
Bolt kit
Dimensions, quantity Bolt torque Ordering number
M5 x 45 DIN 912-10.9
8.9 Nm(6.6 ft-lbs)
15845100
10-24 UNC x1.75 2 000 107
Seal kit Dimensions in millimeters
Type
Dimensions, quantity
Ordering number
O-ring Square ring
Standard NBR
22 x 2 NBR90 (2 pcs.) 9.25 x 1.68 NBR70 (4 pcs.)
20980500
28 x 2 (2 pcs.) -
Viton
22 x 2 (2 pcs.) -
209806009.25 x 1.78 (4 pcs.) -
28 x 2 (2 pcs.) -
Spare Parts
3
HA 4005
p-Q Characteristic Measured at n = 32 mm
2
/s (156 SUS )
Type Symbol Crossover
Spool Symbols
Type Symbol Crossover
Dp-Q Characteristic Measured at n = 32 mm
2
/s (156 SUS )
(725)
(1450)
(2176)
(2901)
(3626)
(4351)
(5076)
(2.64) (7.93) (13.21) (18.49) (23.77)
Operating pressure p [bar(PSI)]
Flow Q [GPM (L/min)]
Operating pressure p [bar(PSI)]
Flow Q [GPM (L/min)]
(5.28) (10.57) (15.85) (21.13)
(464)
(348)
(116)
(232)
H11 1
H51 1
C11 1
C51 1
Z11 2
Z51 2
J15 3
R11 4
X11 4
A51 5
Y11 6
Y51 6
P-A P-B A-T B-T P-T
Z111122
C1133342
H1111112
H5111112
Y111111
C51 3 4 2
Z51 1 2
R111122
A51 1 1
Y51 1 1
X111122
J151122
Operating limits for maximum hydraulic power tfansferred by the directional valve. Measured by steering pressure
30 bar (435PSI) + pressure at port T. For respective spool type - see spool symbols.
Pressure drop Dp related to flow rate.
49,3 1.94()
1 0.04()
37,3 1.47()
8 0.32()
12,4 0.49()
9,5 0.37()
5,3 0.21()
D1/L2
THREAD SIZE
1,4 0.06()
45,5 1.79()
43,5 1.71 68 2.68() ()
126(4.96)
155(6.10)
32,5 1.28()
Æ45 1.77()
31 1.22()
25,9( )
1.02
15,5 0.61()
5,1 0.20()
40,5 1.59()
12,5 0.49()
30,2 1.19()
21,5 0.85()
12,7 0.5()
7 0.27()
16,3 0.64()
A
B
T
P
4
HA 4005
Valve Dimensions Dimensions in millimeters (inches)
3
1
4
5
1 Operating element 1
2 Operating element 2
3 Name plate
4 Square ring 9.25 x 1.68 (4 pcs.)
supplied with valve
5 4 mounting holes
2
Thread size Æ D1 L1 L2
M10x1
15,5 (0.610) 1(0.039) 8 (0.315)
G1/8
7/16-20 UNF-2B, SAE-4 21 (0.827) 0,8 (0.032) 14 (0.551)
Caution!
Subject to alteration without notice!
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: sales.cz@argo-hytos.com
www.argo-hytos.com
Required surface finish of
interface
For applications outside the given parameters, please consult us.
Other for spool symbols on request.
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
Mounting screws M5 x 45 DIN 912-10.9 or bolts must be ordered separately.
The screws tightening torque is 8.9 Nm (6.6 ft-Ibs).
The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.