TV2-102/M
Size 10 (D05) Q
max
80 l/min (21 GPM) p
max
350 bar (5100 PSI)
13,5(0.53)
24,6(0.97)
39,7(1.56)
46(1.81)
16,7(0.66)
27(1.06)
37,3(1.47)
50,8(2)
54(2.13)
3,2(0.13)
4xM6 -6Hx15+1/18-2
T
A
A
B
P
T
B
ISO 4401-05-04-0-05
50 100 150 200 250 300 350
0
40
60
20
80
(725) (1450) (2180) (2900) (3630) (4350)
(5080)
()10.6
()15.5
()5.3
()21.1
50 100 150 200 250 300 350
0
40
60
20
80
(725) (1450) (2180) (2900) (3630) (4350)
(5080)
()10.6
()15.5
()5.3
()21.1
Subject to change · TV2-102/M_5169_1en_02/2016
www.argo-hytos.com
Page 1
2-Way Pressure Compensator, Spool-Type, Direct-Acting, Modular
Technical Features
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
Flow Q [l/min (GPM)]
Pressure p [bar (PSI)]
Flow Q [l/min (GPM)]
Pressure p [bar (PSI)]
Functional Description
Technical Data
Valve size 10 (D05)
Max. operating pressure bar (PSI) 350 (5100)
Max. flow l/min (GPM) 80 (21.1)
Control pressure differential bar (PSI) 4... 14 (58…203)
Fluid temperature range (NBR) °C (°F) -30.... +100 (-22... +212)
Fluid temperature range (FPM) °C (°F) -20.... +120 (-4... +248)
Mass (Models A, B, C / D, E, F) kg (Ibs) 3.7 (8.2) / 6.65 (14.7)
Data Sheet Type
General information GI_0060 Products and operating conditions
Mounting interface SMT_0019 Size 10
Spare parts SP_8010
2-Way pressure compensator, spool-type, direct-acting with subplate interface
acc. to ISO 4401, DIN 24340 (CETOP 05)
Modular design for vertical stacking assemblies with built-in load sensing shuttle valve
Meter-in flow control models with load sensing from optional consumer ports
The valve keeps the pressure drop between the inlet and the pilot connection at a constant level
Used as a load sensing valve with proportional directional and flow valves to control
the flow rate independently of the pressure variations
Excellent stability throughout the flow range, rapid response to dynamic pressure changes
Adjustable by allen key or hand knob, or delivered with fix setting
Quiet and modulate response to load changes
Hardened precision parts
High flow capacity
In the standard version, the valve housing is phosphated and steel parts zinc-coated
for 240 h protection acc. to ISO 9227
A normally open, direct-acting, spring loaded 2-way pressure compensator in the form of a sandwich plate.
They consist of a body, a 2-way screw-in cartridge compensator TV2-102/S and a load shuttle valve.
2-Way compensators for meter-in applications (models A,B,C)
The 2-way meter-in pressure compensators will maintain a constant pressure difference across the metering
edge of the proportional directional valve. In this case, the pressure variations due to load changes, as well as
pump pressure changes are compensated. Any increase in pump pressure does not affect the flow.
The meter-in compensators may only be used with positive load direction. They are designated for load
compensation in inlet port P.
2-Way compensators for meter-out applications (models D,E,F)
In systems with changing load directions or negative load, the use of meter-out pressure compensators is
required. With respect to the application, a valve with pressure compensator installed in one or in both
actuator ports are available. The pressure compensator is always mounted between the actuator and
the proportional directional valve. The valve will maintain the pressure difference between A and T or B and T
constant. The flow rate and the flow direction are adjusted by the proportional directional valve.
To enable free reverse flow, two by-pass check valves are incorporated into the valve body.
Regulated flow related to input pressure
The characteristic of the pressure compensator corresponds to the flow rate of a PRM2-103Z11/60 proportional directional valve. If the pressure
resistance increases due to a flow rate increase, the pressure differential also has to increase in order to ensure correct regulation.
Ports P, A, B, T - max. 11.2 mm (0.44 in)
TV2-102/MC Meter-in compensator
TV2-102/MD Meter-out compensator
TV2-102/M -
26 (1.02)
12 (0.47)
106 (4.17) 70 (2.76)
70 (2.76)
121 4.76()
15
(0.59)
TA2
TB2
B2A2
P2
1
(0.5 )
4
5
54 (2.13)
145 (5.71)
173 (6.81)
45,5 (1.79)
P2
A2
B2
TB2
TA2
12 (0.47)
100 (3.94)
70 (2.76)
35 (1.38)
37 (1.47)
32
5
)
max. 31(1.22)
M10x1
40 (1.57
TA1A1P1 TB1B1
LS
TA2A2P2 TB2B2
TA1A1P1 TB1B1
TA2A2P2 TB2B2
LS
TA1A1P1 TB1B1
TA2A2P2
TB2
B2
LS
TA
1A1P1 TB1B1
TA
2A2P2 TB2B2
LS
TA1A1P1 TB1B1
TA2A2P2 TB2B2
LS
LS
TA
1A1P1 TB1B1
TA
2A2P2 TB2B2
LS
PT
AB
ba
PT
AB
ba
Meter-in compensator
Meter-out compensator
SHUTTLE
VALVE
PROPORTIONAL
DIRECTIONAL
VALVE
PRESSURE
COMPENSATOR
PROPORTIONAL
DIRECTIONAL
VALVE
PRESSURE
COMPENSATOR
10+2 Nm
(7.4+1.5 lbf.ft)
A B C D E F
A
B
C
D
E
F
1
2
C
S
RP
Subject to change · TV2-102/M_5169_1en_02/2016
www.argo-hytos.com
Page 2
Ordering Code
Functional Symbols
2-Way pressure compensator,
spool-type, direct-acting, modular
No designation
V
Seals
NBR
FPM (Viton)
Dimensions in millimeters (inches)
Notice: The orientation of the symbol on the name plate corresponds with the valve function.
valve side
No designation
A
B
Surface treatment
housing phosphated, steel parts
zinc-coated (ZnCr-3), ISO 9227 (240 h)
zinc-coated (ZnCr-3), ISO 9227 (240 h)
zinc-coated (ZnNi), ISO 9227 (520 h)
Model
Meter-in compensator in channel A
Meter-in compensator in channel B
Meter-in compensator in channel A and B
Meter-out compensator in channel A and B
Meter-out compensator in channel A
Meter-out compensator in channel B
Adjustment option
fixed setting, non adjustable
allen key (hex. 5), without protective cap
hand knob, plastic
Control pressure differential
4 - 12 bar (58 - 174 PSI), 10 bar (145 PSI) “C” Model
10 - 14 bar (145 - 203 PSI), 14 bar (203 PSI) “C” Model
TV2-102/MD*C Meter-out compensator
Model *S Model *RP
Adapter M10x1/G1/4-ED
addition of equipment
for external LS connection
Ordering number:19860700
TV2-102/MC*C Meter-in compensator
Application Example
Sandwich plate
subplate
or manifold side
Applicable only for „TV*C“ versions. (Fixed setting, not adjustable)