TV2-062/M
Size 06 (D03) Q
max
35 l/min (9 GPM) p
max
350 bar (5100 PSI)
ISO 4401-03-02-0-05
Ports P, A, B, T max. ∅7.5 mm (0.29)
210
()2.6
()4.0
()1.3
()7.9
()9.2
()5.3
()6.6
0
30
60
90
120 150
10
15
5
30
35
20
25
180
3050()440 ()870 ()1310 ()2180 ()2610()1740
()11.9
40
()10.6
45
()2.6
()4.0
()1.3
()7.9
()9.2
()5.3
()6.6
0
50
100
150
200 250
10
15
5
30
35
20
25
300
()730 ()1450 ()2180 ()3630 ()4350()2900
5
Subject to change · TV2-062/M_5166_1en_02/2016
www.argo-hytos.com
Page 1
2-Way Pressure Compensator, Spool-Type, Direct-Acting, Modular
Technical Features
Functional Description
Technical Data
A normally open, direct-acting, spring loaded 2-way pressure compensator in the form of a sandwich plate.
2-Way compensators for meter-in applications (models A,B,C, CX)
The 2-way meter-in pressure compensators will maintain a constant pressure difference across the metering
edge of the proportional directional valve. In this case, the pressure variations due to load changes, as well as
pump pressure changes are compensated. Any increase in pump pressure does not affect the flow.
The meter-in compensators may only be used with positive load direction.
They are designated for load compensation in inlet port P.
2-Way compensators for meter-out applications (models D,E,F)
In systems with changing load directions or negative load, the use of meter-out pressure compensators
is required. With respect to the application, a valve with a pressure compensator installed in one or in both
actuator ports are available.
The pressure compensator is always mounted between the actuator and the proportional directional valve.
The valve will maintain the pressure difference between A and T or B and T constant.
The flow rate and the flow direction are adjusted by the proportional directional valve.
To enable free reverse flow, two by-pass check valves are incorporated into the valve body.
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
Flow Q [l/min (GPM)]
Pressure p [bar (PSI)]
Flow Q [l/min (GPM)]
Pressure p [bar (PSI)]
› 2-Way pressure compensator, spool-type, direct-acting with subplate interface
acc. to ISO 4401, DIN 24340 (CETOP 03)
› Modular design for vertical stacking assemblies with built-in load sensing shuttle valve
› Meter-in and meter-out flow control models with integrated by-pass check valves
› The valve keeps the pressure drop between the inlet and the pilot connection at a constant level
› Used as a load sensing valve with proportional directional and flow valves to control
the flow rate independently of the pressure variations
› Excellent stability throughout the flow range, rapid response to dynamic pressure changes
› Quiet and modulate response to load changes
› Hardened precision parts
› Load sensing port from mounting pattern side option
› High flow capacity
› In the standard version, the valve housing is phosphated and steel parts zinc-coated
for 240 h protection acc. to ISO 9227
Valve size 06 (D03)
Max. operating pressure bar (PSI) 350 (5080)
Max. flow l/min (GPM) 35 (9.2)
Control pressure differential bar (PSI) 10 (145)
Fluid temperature range (NBR) °C (°F) -30 .... +100 (-22 ... +212)
Fluid temperature range (FPM) °C (°F) -20 .... +120 (-4 ... +248)
Mass (all models) kg (Ibs) 1.0 (2.20)
Data Sheet Type
General information GI_0060 Products and operating conditions
Mounting interface SMT_0019 Size 06
Spare parts SP_8010
Regulated flow related to input pressure
TV2-062/MC Meter-in compensator
TV2-062/MD Meter-out compensator
The characteristic of the pressure compensator corresponds to the flow rate of a PRM2-063Z11/30 proportional directional valve. If the pressure
resistance increases due to a flow rate increase, the pressure differential also has to increase in order to ensure correct regulation.