2
HA 4056
Ordering Code
RPEL1-06 /
Spool symbols
see the table Spool symbols
Nominal size
Directional Control Valve
Solenoid Operated
Number of operating positions
two positions
2
three positions 3
Rated supply voltage of solenoids
(at the coil terminals)
12 V DC / 2.41 A
01200
24 V DC / 1.16 A 02400
Other voltage on request.
Manual overide
no designation standard
M2 covered with rubber boot
Type of the solenoid coil
E1 with the connector to EN 1745301-803-A
E2 with the integrated quenching diode and
the connector to EN 1745301-803-A
E3 with the connector AMP-Junior-Timer 2 PIN
E4 with integrated quenching diode and
the connector AMP-Junior-Timer 2 PIN
E12 with the connector Deutsch DT04-2P
E13 with integrated quenching diode and
the connector Deutsch DT04-2P
For selection of the solenoid coil and the terminal box
type use catalogue HA 8007.
Technical Data
Nominal size mm (US) 06 (03)
Maximum flow L/min (GPM) see p-Q characteristics
Max. operating pressure at porte P, A, B bar (PSI) 250 (3626)
Max. operating pressure at port T bar (PSI) 100 (1450)
Pressure drop bar (PSI) see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for NBR seals °C (°F) -30 ... +80 (-22... +176)
Ambient temperature, max. °C (°F) up to +50 (122)
Viscosity range mm
2
/s (SUS) 20 ... 400 (98... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Max. allowable voltage variation % ±10
Max. switching frequency 1/h 10 000
Switching time, on: at n=32 mm
2
/s (156 SUS) ms 30 ... 50
Switching time, off: at n=32 mm
2
/s (156 SUS) ms 10 ... 50
Duty cycle % 100
Service life cycles 10
6
Type of protection to EN 60 529 see connector definition IP 65, IP 67, IP 69K according to the selected design coils*
Weigt - valve with 1 solenoid
- valve with 2 solenoids
kg (lbs)
1.4 (3.1)
1.6 (3.5)
Mounting position unrestricted
*That degree of protection only applies with a properly attached connector plug