Subject to change · 40.90-e · 0215
Page 2
www.argo-hytos.com
Characteristics
Operating pressure
0 ... 400 bar, min. 2 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 630 bar, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Number of cycles n
Operating pressure p [bar]
Nominal flow rate
Up to 1000 l/min (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s
› element service life > 1000 operating hours at an average
fluid contamination of 0.07 g per l/min flow volume
› flow velocity in the connection lines:
up to 250 bar ≤ 8 m/s
> 250 bar ≤ 12 m/s
Filter fineness
5 µm(c) ... 16 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20)
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
Viscosity at nominal flow rate
› at operating temperature: ν < 60 mm
2
/s
› as starting viscosity: ν
max
= 1200 mm
2
/s
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70 % ∆p of the cracking
pressure of the by-pass valve on the vertical axis. Draw a
horizontal line so that it intersects the ∆p curve at a point.
Read this point on the horizontal axis for the viscosity.
Mounting position
Preferably vertical. The filter head can be mounted in either the
uppermost position or the inverse as required.
Connection
SAE-flange (6000 psi).
Sizes see Selection Chart, column 6 (other connections on
request).