RPE3-06
Size 06 (D03) Q
max
80 l/min (21 GPM) p
max
350 bar (5100 PSI)
TP
B
A
G
0,75 (0.03)
4xM5-6Hx13
15,5 (0.61)
31,75 (1.25)
5,1 (0.20)
25,9 (1.16)
31 (1.22)
12,7 (0.50)
21,5 (0.85)
30,2 (1.18)
40,5 (1.59)
Ports P, A, B, T - max 7.5 mm (0.29 in)
ISO 4401-03-02-0-05
Spool symbol
1 Z11 5 F11 7 Z91
6 C11 3 R11 5 R31
5 H11 4 R21 5 H51
1 P11 5 A51 7 F51
2 Y11 1 P51 3 X11
5 L21 2 Y51 7 K11
8 B11 6 C51 7 N11
6 Y41 1 Z51 10 X25
1 Z21 7 Z71 1 J15
5 C41 7 Z81 9 J75
Spool symbol
P-A P-B A-T B-T P-T P-A P-B A-T B-T P-T
Z11,L21,B11,R11
R21,X11,N11,J15
2 2 3 3 P51 1 3
C11 5 5 5 6 3 Y51 2 2
H11 2 2 2 3 3 C51 2 3 4
P11 1 1 3 3 Z71 3 3
Y11 2 2 2 2 Z81 3 3
Y41 3 3 3 3 Z91 3 3 3
Z21,Z51,H51 2 3 R31 2 3
C41 4 4 5 F51 2 3
F11 1 2 3 3 K11 2 3
A51,J75 2 2 X25 3 3 3
70 80
(21.1)
(18.5)
(1450)
(2176)
(725)
(4351)
(5076)
(2901)
(3626)
0
10 20
30
40 50
100
150
50
300
350
200
250
(5.3) (10.6)
60
(13.2) (15.9)(7.9)(2.6)
9
2
7
10
4
3
8
5
6
1
1, 2, 3, 4,
5, 9,10
6, 7, 8
Subject to change · RPE3-06_4010_9en_01/2026
www.argo-hytos.com
Page 1
4/2 and 4/3 Directional Control Valve, Solenoid Operated
Technical Features
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
Pressure drop related to flow rate
Technical Data
Operating pressure p [bar (PSI)]
Flow Q [l/min (GPM)] Flow Q [l/min (GPM)]
Pressure drop Δp [bar (PSI)]
Operating limits
Direct acting, directional control valve with subplate mounting interface acc. to ISO 4401, DIN 24340 (CETOP 03)
High transmitted hydraulic power up to 350 bar with optimized design to minimize pressure drop
Five chamber housing design with reduced hydraulic power dependence on fluid viscosity
The valve is available with interchangeable DC solenoids, also for AC power supply using a built-in rectifier bridge
Wide range of solenoid electrical terminal versions available
Wide range of interchangeable spools and manual overrides available
CSA Certificate upon request
Inductive contactless Normally Open and Normally Closed spool position sensor option
Soft-shift spool speed control option
The coil is fastened to the core tube with a retaining nut and can be rotated by 360° to suit the available space
In the standard version, the valve housing is phosphated for basic surface corrosion protection and
as preparation for painting. Steel parts are zinc-coated for 240 h salt spray protection acc. to ISO 9227
Enhanced surface protection for mobile sector available for the valve housing and steel parts
(ISO 9227, 520 h salt spray)
For operating limits under conditions and flow directions other than shown contact our technical support. Admissible operating limits may be considerably
lower with only one direction of flow (A or B plugged, or without flow.)
Valve size 06 (D03)
Max. flow l/min (GPM) 80 (21.1)
Max. operating pressure at ports P, A, B bar (PSI)
standard 350 (5080)
320 (4640) acc. to CSA
Max. operating pressure at port T bar (PSI) 210 (3050)
Fluid temperature range (NBR) °C (°F) -30 ... +80 (-22 ... +176)
Fluid temperature range (FPM) °C (°F) -20 ... +80 (-4 ... +176)
Ambient temperature range °C (°F) -30 ... +50 (-22 ... +122)
Supply voltage tolerance % AC: ±10 DC: ±10
Max. switching frequency 1/h 15 000
Switching time at ν=32 mm
2
/s (156 SUS)
ON ms AC: 30 ... 40 DC: 30 ... 50
OFF ms AC: 30 ... 70 DC: 10 ... 50
Enclosure type acc. to EN 60529 IP65 / IP67 (see Dimensions, page 3)
Weight - valve with 1 solenoid kg (lbs) 1.6 (3.52)
- valve with 2 solenoids 2.2(4.85)
Datasheet Type
General information HA 0060 Products and operating conditions
Coil types / connectors HA 8007 / HA 8008 C22B* / K*
Mounting interface HA 0019 Size 06
Spare parts HA 8010
Operating limits for maximum hydraulic power at rated temperature
and supply voltage equal to 90 % nominal.
RPE3 - 06 / -
01200
02400
02700
20500
02450
12060
23050
E1
E2
E3A
E4A
E5
E8
E9
E12A
E13A
Subject to change · RPE3-06_4010_9en_01/2026
www.argo-hytos.com
Page 2
Ordering Code
Spool Symbols
Type Symbol Interposition Type Symbol Interposition Type Symbol Interposition
Spool symbols
see the table “Spool Symbols“
Valve size
No designation
A
B
No designation
N1
N2
N3
N4
N5
N7
N8
N9
No designation
T1
No designation
V
Connector
EN 175301-803-A
E1 with quenching diode
AMP Junior Timer - axial direction (2 pins; male)
E3A with quenching diode
EN 175301-803-A with integrated rectifier
Loose conductors (two insulated wires)
E8 with quenching diode
Deutsch DT04-2P - axial direction (2 pins; male)
E12A with quenching diode
2
3
Number of spool positions
two positions
three positions
No designation
S1
S4
- For directional valves with two solenoids, one solenoid must be
de-energized before the other solenoid can be charged.
- For AC voltage supply use coils with connector type E5.
- For other solenoid voltage supply options see datasheet HA 8007.
- The solenoid operated valves are delivered without connectors.
For available connectors see datasheet HA 8008.
- The orifice to the P port can be ordered separately, see datasheet HA 8010.
- Mounting bolts M5 x 45 DIN 912-10.9 or studs must be ordered separately.
Tightening torque is 8.9+1 Nm (6.56+0.7 Ibf.ft).
- Besides the commonly used valve versions shown other special models are available.
Contact our technical support for their identification, feasibility and operating limits.
Manual override
standard
cap nut covered
rubber boot protected
detent assembly with the ball
hand screw
socket head screw, size 3
detent assembly with the nut
with ball
without manual override
4/2 and 4/3
directional control valve,
solenoid operated
Rated supply voltage of solenoids
(at the coil terminals)
12 V DC / 2.72 A
24 V DC / 1.29 A
27 V DC / 1.07 A
205 V DC / 0.15 A
24 V AC / 1.56 A / 50 (60 Hz)
120 V AC / 0.26 A / 60 Hz
230 V AC / 0.15 A / 50 (60) Hz
CSA upon request - only for 320 bar (4640 PSI)
Soft-shift spool speed control
without soft-shift control
orifice 0.7 mm (0.03 inch) in solenoid*
Surface treatment
standard
zinc-coated (ZnCr-3), ISO 9227 (240 h)
zinc-coated (ZnNi), ISO 9227 (520 h)
Seals
NBR
FPM (Viton)
Spool monitoring
without sensors
normally-open sensor
normally-closed sensor
CSA Certified
without certification
certification CSA
No designation
U
*The manual overrides listed in the Ordering Code cannot be used
when using the spool speed control (T1)
45 77)(1.
32,5(1.27)
52 (2.05)
32,5(1.28)
A
38,2 (1.51)
46,3 (1.82)
Subject to change · RPE3-06_4010_9en_01/2026
www.argo-hytos.com
Page 3
Type of Solenoid Coil in millimeters (inches)
In case of solenoid malfun-
ction or power failure, the
spool of the valve can be
shifted by manual override
as long as the pressure in
port T does not exceed 25
bar (363 PSI). For alternative
manual overrides contact
our technical support.
Note:
A = Standard 300 mm,
(11.8 in) other lengths on
demand
The specified IP rating applies only in the case of correctly connected connectors (male + female) with the corresponding IP rating.
E1, E2 / IP65 E3A, E4A / IP65 / IP67 E5 / IP65 E8, E9 E12A, E13A / IP67 / 69K
Manual Override in millimeters (inches)
2
Two-Position Directional Control Valve
a(b) Sa(Sb)
LED
S1 S4 S1 S4
0 1 0 ON OFF
1 0 1 OFF ON
Three-Position Directional Control Valve
a(b) Sa(Sb)
LED
S1 S4 S1 S4
a b Sa Sb Sa Sb Sa - LED Sb - LED Sa - LED Sb - LED
0 0 1 1 0 0 ON ON OFF OFF
1 0 0 1 1 0 OFF ON ON OFF
0 1 1 0 0 1 ON OFF OFF ON
Technical Data of the Sensor S1, S4
Rated power supply voltage V 24 DC
Power supply voltage range V 10 ... 30 DC
Rated current mA 200
Sensor enclosure protection (EN 60529) IP 67
Max. operating pressure at port T bar (PSI) 210 (3046)
Switching frequency Hz 1000
Ambient temperature range °C (°F) -25 ... +80 (-13 ... +176)
Technical Data of the Connector
Power supply voltage range V 10 ... 30 DC
Ambient temperature range °C (°F) -25 ... +80 (-13 ... +176)
Indicator yellow LED
Signal of solenoid
Signal of sensor
S1 - Circuit diagram for the
normally - OPEN sensor
S4 - Circuit diagram of the
normally - CLOSED sensor
PNP Sensor
Connector
Connector
PNP Sensor
Typical configurations of the valve with a sensor:
3-position valve with two solenoids, equipped with two sensors
2-position valve with one solenoid, equipped with one sensor on the solenoid side
2-position valve with a detent assembly of spool, equipped with one sensor on the side of the solenoid
which moves the spool from the basic position to the switched position according to the spool symbol
Note: the sensor always indicates the change of spool position realised by the energised solenoid,
mounted on the side of the sensor.
Function of the position
sensor:
In the basic position (when
the solenoid is switched off),
a steel core, connected to
the spool, is under the position
sensor. The sensor is activated,
it means contacts of the sensor
S1 are closed and contacts of
the sensor S4 are open. After
switching on the solenoid
the spool with core moves out
of the sensor range
and the sensor is deactivated.
Spool Position Sensor
No designation
- standard
N1- cap nut covered N2- rubber boot protected
N3 - detent assembly
with the ball
N4 - hand screw
N5 - socket head
screw, size 3
N7 - detent assembly
with the nut
N8 - with ball N9 - without manual override
61,5 (2.42)
(111 4.37))
A
B
Sa (Sb)
Sa Sb
a (b)
b
a
68,5 (2.7)
49,3 (1.94)
68 (2.68)
(45,5( ))1.79
8,0 (0.31)
26,5 (1.04)
a
a
a
b
b
21,5 (0.85)
a
26,5 (1.04)
A
T
Z
12,5
(0.49)
15,5 (0.6)
Z
P
37,3
(1.47
)
1 (5.9)50
b
b
9,5 (0.37)
(73
7
(2.8 ))
214 (8.43)
2 7 ( 1)6 10.5
99,5 (3.92)
176 (6.93)
99,3 (3.90)
A
92,5 (3.64) 12 (3.64)
24(0.95)
B
84 (3.31)
8,0 (0.31)
RPE3-063*/*E1*S
RPE3-063*/*E1*
Required surface quality of
the counterpart
2
1
3
(86,5 (3.40))
a
2+0.3 Nm
(1.5+0.2 lbf.ft)
3
Subject to change · RPE3-06_4010_9en_01/2026
www.argo-hytos.com
Page 4
Spool Speed Control in millimeters (inches)
Dimensions in millimeters (inches)
Designation T1 Important:
This directional valve provides the means to control spool soft shifting by an orifice situated
in the solenoid armature. To ensure the proper function of the valve, unobstructed venting
of the solenoid is required through the bleeding plug (1). The plugs are accessible after
removing the rubber boot (2) from the solenoid cap nut (3).
The valve spool can be adjusted manually by pushing on the tightened bleeding plug.
Switching time ON and OFF
300 ... 800 ms
The switching times shown are valid for viscosity ν = 32 mm
2
/s (156 SUS) and nominal voltage.
They depend on working pressure and flow rate of the directional control valve.
Valve with two solenoids
Plastic nut
3+1 Nm
(2.2+0.7 lbf.ft)
Valve with one solenoid „b“
Spool symbols X11, Z11,
C11, H11, K11, N11, F11
Valve with one solenoid „a“
Spool symbols R11, R21,
A51, P51, Y51, Z51, C51,
R31, Z71, Z81, Z91,
H51, F51, X25
Mounting screws 8.9+1 Nm (6.56+0.7 lbf.ft)
M5x45 DIN 912-10.9