TSE3-D
p
max
up to 400 bar (5800 PSI)
Subject to change · TSE3-D_9208_2en_02/2020
www.argo-hytos.com
Page 1
Electronic pressure switch / sensor with two outputs
› Two switching outputs, one programmable as IO-Link, and one as
a analogue current / voltage output
› Red/green display for visualisation of the un/acceptable range
› Rotating body for optimal position of connector
› Long-term stability thanks to high overload protection
› Robust design and stainless-steel body for use in harsh industrial environments
› High vibration and shock resistance
› UL approval and certification acc. to PED direction
Technical Features
Programmable pressure sensor with a metallic thin film measuring cell for measuring fluid system pressure, e.g. in hydraulic circuits, and indication
of reaching the adjusted pressure value. The stainless-steel body is provided with connecting thread G 1/4 with FKM sealing ring. An electric
connection is realized by four-pin connector M12 x 1. The 4-digit display and programming buttons are on the top surface. The sensor is suitable
for industrial usage thanks to robust design, vibration and shock resistance.
Outputs:
OUT1 (pin 4): switching signal for indication of adjusted value of system pressure or
Communication via IO-Link (COM2)
OUT2 (pin 2): switching signal for indication of adjusted value of system pressure or
analogue signal 4 … 20 mA / 0 … 10 V
Technical Data
Functional Description
Application
Measuring element Metallic thin film measuring cell
Application For industrial applications
Media Liquids
Medium temperature °C (°F) -25 … +80 (-13 ... +176)
Ambient temperature °C (°F) -25 … +80 (-13 ... +176) [in case of cULus certification: -25 … 60 (-13 ... +140)]
Storage temperature °C (°F) -40 … +100 (-40 ... +212)
Pressure range bar (PSI) 800 (11603)
Min. bursting pressure bar (PSI) 1700 (24660)
Vacuum resistance mbar (PSI) -1000 (-14.5)
Measuring / setting range
Measuring range bar (PSI) 0 … 400 (0 … 5800)
Set point (SP) bar (PSI) 1.5 … 400 (21.8 … 5800)
Reset point (rP) bar (PSI) 1 … 399.5 (14.5 … 5790)
Analogue start point bar (PSI) 0 … 320 (0 … 4640)
Analogue end point bar (PSI) 80 … 400 (1160 … 5800)
In steps of bar (PSI) 0.5 (7.3)
Electrical parameters
Supply voltage V DC 18 …. 30 (acc. to EN 50178 SELV/PELV)
Current consumption mA < 35
Min. insulation resistance MΩ 100 (500 V DC)
Protection class III
IP protection IP65, IP67
Power-on delay time s 0.3
Protection Reverse polarity protection, integrated watchdog
Outputs
Switching signal (pin 2, 4) PNP / NPN switcher, normally open / closed contacts
Max. voltage drop switching output DC V 2
Permanent current rating of switching output DC mA 250
Switching frequency DC Hz < 500
Analogue current output (pin 2) mA 4 ... 20 (scalable 1:5)
Max. load resistance Ω 500
Analogue voltage output (pin 2) V 0 ….. 10 (scalable 1:5)
Min. load resistance Ω 2000
Electric protection Pulsed short-circuit and overload protection
Accuracy / deviations
Switch point accuracy % < ± 0.4 (of the span); turn down 1:1
Repeatability % < ± 0.1 (of the span); with temperature fluctuations < 10 K; turn down 1:1
Characteristics deviation %
< ± 0.25 (of the span) Best fit straight line (BFSL)
< ± 0.5 (of the span) Limit value setting (LS)
Hysteresis deviation % < ± 0.1 (of the span)
Long-term stability % < ± 0.05 (of the span) per 6 months; turn down 1:1
Temperature coefficient zero point % 0.2 (of the span / 10 K) in the range -25 … +80 °C (-13 ... +176 °F)
Temperature coefficient span % 0.2 (of the span / 10 K) in the range -25 … +80 °C (-13 ... +176 °F)
Response times
Response times ms < 1.5
Delay time programmable dS, dr s 0 … 50
Damping for the switching output dAP s 0 … 4
Damping for the analogue output dAA s 0 … 4
Max. response time analogue output ms 3