TSE3-D
p
max
up to 400 bar (5800 PSI)
Subject to change · TSE3-D_9208_2en_02/2020
www.argo-hytos.com
Page 1
Electronic pressure switch / sensor with two outputs
Two switching outputs, one programmable as IO-Link, and one as
a analogue current / voltage output
Red/green display for visualisation of the un/acceptable range
Rotating body for optimal position of connector
Long-term stability thanks to high overload protection
Robust design and stainless-steel body for use in harsh industrial environments
High vibration and shock resistance
UL approval and certification acc. to PED direction
Technical Features
Programmable pressure sensor with a metallic thin film measuring cell for measuring fluid system pressure, e.g. in hydraulic circuits, and indication
of reaching the adjusted pressure value. The stainless-steel body is provided with connecting thread G 1/4 with FKM sealing ring. An electric
connection is realized by four-pin connector M12 x 1. The 4-digit display and programming buttons are on the top surface. The sensor is suitable
for industrial usage thanks to robust design, vibration and shock resistance.
Outputs:
OUT1 (pin 4): switching signal for indication of adjusted value of system pressure or
Communication via IO-Link (COM2)
OUT2 (pin 2): switching signal for indication of adjusted value of system pressure or
analogue signal 4 … 20 mA / 0 … 10 V
Technical Data
Functional Description
Application
Measuring element Metallic thin film measuring cell
Application For industrial applications
Media Liquids
Medium temperature °C (°F) -25 … +80 (-13 ... +176)
Ambient temperature °C (°F) -25 … +80 (-13 ... +176) [in case of cULus certification: -25 … 60 (-13 ... +140)]
Storage temperature °C (°F) -40 … +100 (-40 ... +212)
Pressure range bar (PSI) 800 (11603)
Min. bursting pressure bar (PSI) 1700 (24660)
Vacuum resistance mbar (PSI) -1000 (-14.5)
Measuring / setting range
Measuring range bar (PSI) 0 … 400 (0 … 5800)
Set point (SP) bar (PSI) 1.5 … 400 (21.8 … 5800)
Reset point (rP) bar (PSI) 1 … 399.5 (14.5 … 5790)
Analogue start point bar (PSI) 0 … 320 (0 … 4640)
Analogue end point bar (PSI) 80 … 400 (1160 … 5800)
In steps of bar (PSI) 0.5 (7.3)
Electrical parameters
Supply voltage V DC 18 …. 30 (acc. to EN 50178 SELV/PELV)
Current consumption mA < 35
Min. insulation resistance 100 (500 V DC)
Protection class III
IP protection IP65, IP67
Power-on delay time s 0.3
Protection Reverse polarity protection, integrated watchdog
Outputs
Switching signal (pin 2, 4) PNP / NPN switcher, normally open / closed contacts
Max. voltage drop switching output DC V 2
Permanent current rating of switching output DC mA 250
Switching frequency DC Hz < 500
Analogue current output (pin 2) mA 4 ... 20 (scalable 1:5)
Max. load resistance Ω 500
Analogue voltage output (pin 2) V 0 ….. 10 (scalable 1:5)
Min. load resistance Ω 2000
Electric protection Pulsed short-circuit and overload protection
Accuracy / deviations
Switch point accuracy % < ± 0.4 (of the span); turn down 1:1
Repeatability % < ± 0.1 (of the span); with temperature fluctuations < 10 K; turn down 1:1
Characteristics deviation %
< ± 0.25 (of the span) Best fit straight line (BFSL)
< ± 0.5 (of the span) Limit value setting (LS)
Hysteresis deviation % < ± 0.1 (of the span)
Long-term stability % < ± 0.05 (of the span) per 6 months; turn down 1:1
Temperature coefficient zero point % 0.2 (of the span / 10 K) in the range -25 … +80 °C (-13 ... +176 °F)
Temperature coefficient span % 0.2 (of the span / 10 K) in the range -25 … +80 °C (-13 ... +176 °F)
Response times
Response times ms < 1.5
Delay time programmable dS, dr s 0 … 50
Damping for the switching output dAP s 0 … 4
Damping for the analogue output dAA s 0 … 4
Max. response time analogue output ms 3
TSE3-D - 400 - 2 - 1 - 1
TSE3-D
1
4
2
3
OUT1
OUT2
L+
L-
BN
WH
BK
BU
4
3
1
2
34(1.34)
16,5(0.65)
92,7(3.65)
27(1.06)
G1/4
49,4(1.95)
M12x1
65(2.56)
12(0.47)
30
43
1
2
5
brown
white
blue
black
cable
Connector without cable
Connector with cable
Subject to change · TSE3-D_9208_2en_02/2020
www.argo-hytos.com
Page 2
Software /programming
Parameter setting options
Switching mode: hysteresis / windows; contacts normally open / closed;
switch-on / switch-off delay; damping; display unit,
current / voltage analogue output
Interfaces
Communication interface (pin 4) IO-Link
Transmission type COM2
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link device ID 459 d /00 01 cb h
Profiles Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time ms 2.3
Tests / approvals
EMC DIN EN 61000-6-2, DIN EN 61000-6-3
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10 ….2000 Hz)
MTTF years 129
UL approval Approval No. J014
Pressure Equipment Directive
Sound Engineering Practice; can be used for group 2 fluids;
group 1 fluids on request
Mechanical parameters
Weight kg (lbs) 0.26 (0.57)
Materials
Stainless steel 1.4542 (17-4 PH / 630) and 1.4404 (316L); PBT+PC-GF30;
PBT-GF20;PC
Materials (wetted parts) Stainless steel 1.4542 (17-4 PH / 630)
Min. pressure cycles 100 million
Tightening torque Nm (lbf.ft) 25 … 35 (18.4 ... 25.8) (depends on lubrication, seal and pressure rating)
Circuit connection
External thread G 1/4 (DIN EN ISO 1179-2);
Internal thread M5 for restrictor
Sealing ring FKM (DIN 3869)
Display, operating elements
Display unit 3x LED, green (bar, PSI, MPa)
Display switching status 2x LED yellow
Measured values Alphanumeric display, red / green, 4-digit
Electrical connection
Connector 4-pin; M12 x 1, contacts gold-plated
Ordering Code
Electronic pressure switch /
sensor with two outputs
Setting / measuring range
0 - 400 bar (0 - 5800 PSI)
Number of output signals
switching output or IO-Link connection
switching or analogue output
Electrical connection
4 pin connector M12 x 1
Connection to the circuit
external thread G 1/4
Dimensions in millimeters (inches)
Electrical connection
Connector type Ordering code
without cable 41349600
2m cable 41582300
5m cable 41825200
Connector is not included in order of any
pressure switch or sensor and has to be
ordered separately.
1 – alphanumeric display 4-digit red/green
2 – LEDs Display unit / switching status
3 – programming button
4 - upper part of the housing
can be rotated 345°
5 - Sealing
Output OUT1: switching output