PRMR2-06
Size 06 (D03) Q
max
40 l/min (11 GPM) • p
max
350 bar (5100 PSI)
TP
B
A
G
0,75 (0.03)
4xM5-6Hx13
15,5 (0.61)
31,75 (1.25)
5,1 (0.20)
25,9 (1.16)
31 (1.22)
12,7 (0.50)
21,5 (0.85)
30,2 (1.18)
40,5 (1.59)
ISO 4401-03-02-0-05
Ports P, A, B, T - max. ∅7.5 mm (0.29 in)
Subject to change · PRMR2-06_5177_1en_09/2018
www.argo-hytos.com
Page 1
Proportional Directional Control Valve, with Auxiliary Lever Override
› Direct acting proportional directional control valve with subplate mounting interface
acc. to standards ISO 4401, DIN 24340 (CETOP 03)
› The valve is used for directional and speed control of hydraulic appliances
› Auxiliary lever actuator allows emergency spool control by hand when the solenoids are
deenergised, e.g. in the case of electrical failures or maintenance activities
› The flow rate can be controlled continuously and proportionally to command signal
› The valve can be controlled directly by a current control signal or by means of the electronic
control unit to fully exploit the valve performance. The electronic control unit must be ordered
separately
› Wide range of solenoid electrical terminal versions available
› The five chambers body design reduces the dependence of hydraulic power on fluid viscosity
› The coil is fastened to the actuating system with a plastic nut and can be rotated by 360° to to
position suitable for the space available
› In the standard version, the valve housing is phosphated for basic surface corrosion protection
and as preparation for painting. Steel parts are zinc-coated for 240 h salt spray protection acc.
to ISO 9227
› Enhanced surface protection for mobile sector available for the valve housing and steel parts
(ISO 9227, 520 h salt spray)
Technical Features
Functional Description
The valve is used for speed control and the valve with two solenoids also for control of movement direction of hydraulic appliances. The built-in lever
actuator is intended for manual operating up to maximum pressure 100 bar in channel -T. The manual operating of the valve is usually used in an
emergency situation or for service purposes. The manual actuator can be used only when the solenoids are switched off.
For effective valve control it is recommended to use one of the offered electronic control units:
External analogue control unit EL3E in a plastic box (Data sheet 9145)
External digital control unit EL4 in Eurocard format allows an operation in closed control loop with a feedback signal (Data sheet 9140)
Digital control unit EL6 in plug-in version is basically intended for one-solenoid valve. Two are needed and a coordination of their mutual functions
are necessary for two-solenoid valves. (Data sheet 9150)
Technical Data
Nominal Size 06 (D03)
Max. operating pressure at port P, A, B bar (PSI) 350 (5080)
Max. operating pressure at port T bar (PSI) 100 (1450)
Fluid temperature range (NBR) °C (°F) -30 ... +80 (-22 ... +176)
Fluid temperature range (FPM) °C (°F) -20 ... +80 (-4 ... +176)
Ambient temperature range °C (°F) -30 ... +50 (-22 ... +122)
Hysteresis % ≤ 6
Nominal flow rate Q
n
at ∆p=10 bar (145 PSI) l/min (GPM) 5 (1.13) 8 (2.1) 15 (4.0) 30 (7.9)
Weight - valve with 1 solenoid
- valve with 2 solenoids
kg (lbs)
2.8 (6.2)
3.3 (7.3)
Technical Data of the Proportional Solenoid
Nominal supply voltage V 12 DC 24 DC
Limit current A 2.5 1.0
Mean resistance value at 20 °C (68 °F) Ω 2.3 13.4
Data Sheet Type
General information GI_0060 Products and operating conditions
Coil types / Connectors C_8007 / K_8008 C22B* / K*
Mounting interface SMT_0019 Size 06
Spare parts SP_8010
Subplates DP_0002 DP*-06