RPER3-06
Ports P, A, B, T - max. 7.5 mm (0.9 in)
ISO 4401-03-02-0-05
TP
B
A
G
0,75 (0.03)
4xM5-6Hx13
15,5 (0.61)
31,75 (1.25)
5,1 (0.20)
25,9 (1.16)
31 (1.22)
12,7 (0.50)
21,5 (0.85)
30,2 (1.18)
40,5 (1.59)
RPER3-06 / / - -
01200
02400
02700
20500
02450
12060
23050
E1
E2
E3A
E4A
E5
E8
E9
E12A
E13A
2
3
A19
B19
Subject to change · RPER3-06_4026_2en_02/2021
Page 1
www.argo-hytos.com
Solenoid Operated Directional Control Valve with Auxiliary Lever Override
Technical Features
Technical Data
Valve size 06 (D03)
Max. flow l/min (GPM) 80 (21.1)
Max. operating pressure at port P, A, B bar (PSI) 350 (5080)
Max. operating pressure at port T bar (PSI) 100 (1450)
Fluid temperature range (NBR) °C (°F) -30 ... +80 (-22 ... +176)
Fluid temperature range (FPM) °C (°F) -20 ... +80 (-4 ... +176)
Ambient temperature range °C (°F) -30 ... +50 (-22 ... +122)
Service life cycles 10
6
Rated power supply voltage % AC: ±10 DC: ±10
Max. switching frequency 1/h 10 000
Lever characteristics
Total stroke angle
deg
±20
Working stroke angle ±12 to 20
Operating force N (lbf) 40 (29.5)
Lever device weight kg (lbs) 0.59 (1.3)
Datasheet Type
General information GI_0060 Products and operating conditions
Coil types / connectors C_8007 / K_8008 C22B* / K*
Mounting interface SMT_0019 Size 06
Spare parts SP_8010
Size 06 (D03) Q
max
80 l/min (21 GPM) p
max
350 bar (5100 PSI)
Auxiliary lever overrides for ON-OFF solenoid valves of the type RPE3-06 (Datasheet No. 4010)
with Size 06 and mounting interface acc. to ISO 4401, DIN 24340 (CETOP 03)
Auxiliary lever operators allow the valve to be operated when electrical system is de-energized, e.g.
emergency operation, electrical failures, maintenance activities
Manual lever and actuation element can be rotated in 90° increments for flexible installation
When the valve is electrically operated the hand lever remains stopped in its neutral position
The lever override does not affect the performances of the base valve
In the standard version, the valve housing is phosphated for basic surface corrosion protection and as
preparation for painting. Steel parts are zinc-coated for 240 h salt spray protection acc. to ISO 9227
Enhanced surface protection for mobile sector available for the valve housing and steel parts
(ISO 9227, 520 h salt spray)
Objednací klíč
Spool symbols
see the table “Spool Symbols“
Valve size
Number of valve positions
two
three
4/2 and 4/3 solenoid operated
directional control valve with
auxiliary lever override
Rated supply voltage of solenoids
(at the coil terminals)
12 V DC / 2,72 A
24 V DC / 1,29 A
27 V DC / 1,07 A
205 V DC / 0,15 A
24 V AC / 1,56 A / 50 (60) Hz
120 V AC / 0,26 A / 60 Hz
230 V AC / 0,15 A / 50 (60) Hz
For directional valves with two solenoids, one solenoid must be
de-energized before the other solenoid can be charged.
For AC voltage supply use coils with connector type E5.
For other solenoid voltage supply options see data sheet C_8007.
The solenoid operated valves are delivered without connectors.
For available connectors see data sheet K_8008.
The orifice to the P port can be ordered separately, see data sheet
SP_8010.
Mounting bolts M5 x 45 DIN 912-10.9 or studs must be ordered
separately
Tightening torque is 8.9+1 Nm (6.56+0.7 lbf.ft)
Seals
NBR
FPM (Viton)
Conector
EN 175301-803-A
E1 with quenching diode
AMP Junior Timer - axial direction (2 pins; male)
E3A with quenching diode
EN 175301-803-A with integrated rectifier
loose conductors (two insulated wires)
E8 with quenching diode
Deutsch DT04-2P - axial direction (2 pins; male)
E12A with quenching diode
Surface treatment
standard
zinc-coated (ZnCr-3), ISO 9227 (240 h)
zinc-coated (ZnNi), ISO 9227 (520 h)
Manual lever and position of override actuating section
standard, lever on side A, upward
standard, lever on side B, upward
Lever override length
standard 102 mm
Manual override at actuator system
standard
No designation
A
B
No designation
V
No designation
No designation
For operating limits and pressure drop refer to Datasheet No. 4010 of the base valve RPE3-06.
Besides the commonly used valve versions shown other special models are
available.
Contact our technical support for their identification, feasibility and
operating limits.
RPER3-063*/B19
37,3
(1.47
)
9,5 (0.37)
Z
68 (2.68)
28 (1.1)
56,5 (2.22)
151 (5.94)
57 (2.24)
( 1)27 (10.66 )
45 (1.77)
1 (5.1 )30 2
21,5 (0.85)
A
T
Z-Z
12,5
(0.49)
15,5 (0.61)
P
B
49,3 (1.94)
24(0.95)
45, (1.7 )59
71,3 (2.81)
20°
20°
4 (1.7 )4 3
The lever operator should never be used when any solenoid is energized.
RPER3-063*A19
37,3(1.47)
9,5 (0.37)
8,5 (0.33)
5(3.64)
92, 12 (3.64)
A
49,3 (1.94)
24(0.95)
Z
20 (1)
68 (2.68)
28 (1.1)
56,5 (2.22)
151 (5.94)
57 (2.24)
( 1 )27 (10.66 )
45 (1.77)
21,5 (0.85)
A
T
Z-Z
12,5
(0.49)
15,5 (0.61)
P
B
45, (1.7 )59
71,3 (2.81)
130 (5.12)
206 (8.11)
20°
20°
44 1.73( )
RPER3-062*/A19
Subject to change · RPER3-06_4026_2en_02/2021
Page 2
www.argo-hytos.com
Dimensions in millimeters (in)
Mounting screws 8.9+1 Nm (6.56+0.7 lbf.ft)
M5x45 DIN 912-10,9
Manual lever and actuating section is shown
in the standard supplied position which is the
most frequently used. Both elements can be
rotated to various positions 90° apart.
For other positions of lever and actuating
section consult our technical department for
their identification.
Spool Symbols
Type Symbol Interposition Type Symbol Interposition