RNEH5-16
Size 16 (D07) Q
max
300 l/min (80 GPM) p
max
350 bar (5100 PSI) / 420 bar (6100 PSI)
ISO 4401-07-07-0-05
(52.8)
(66.0)
(13.2) (39.6)(26.4) (79.3)
(1450)
(2176)
(725)
(4351)
(5076)
(2901)
(3626)
200 250 300
0
50
100
150
50
150
1
2
100
250
200
350
300
200 250 300
(58)
(87)
(29)
(116)
(145)
0
50
100
4
6
2
8
10
150
(52.8)
(66.0)
(13.2) (39.6)(26.4) (79.3)
4
3
5
1
2
200 250 300
0
50
100
6
2
150
(52.8)
(66.0)
(13.2) (39.6)(26.4) (79.3)
4
10
8
14
12
(58)
(87)
(24)
(174)
(203)
(116)
(145)
Subject to change · RNEH5-16_4023_2en_04/2019
www.argo-hytos.com
Page 1
4/2 and 4/3 Directional Control Valve, Pilot Operated
Technical Features
Characteristics measured at ν = 32 mm
2
/s (156 SUS)
Technical Data
Directional control valve, internally or externally pilot operated with mounting interface
acc. to ISO 4401, DIN 24340 (CETOP 07)
Driven by an ISO 4401-03 (CETOP 03) solenoid operated directional valve (RNEH)
or a hydraulic pilot operated directional valve (RNH) without pilot valve
Electrohydraulic and hydraulic control ports X and Y
Version for high pressures 420 bar (6090 PSI) available
High transmitted hydraulic power, optimized design to minimize the pressure drop
Flexibly changed from internal pilot or drain to external by inserting or removing
threaded plugs in the main control valve body
Wide range of interchangeable spools and valve controls available
Soft-shift, spool speed, main stroke limiter control options
In the standard version, the valve housing is phosphated and steel parts are zinc-coated
for 240 h protection acc. to ISO 9227
Enhanced surface protection for mobile sector for up to 520 h salt spray acc to ISO 9227 available
Operating limits Pressure drop related to flow rate Pressure drop related to flow rate
Valve type RN*5-16 RN*5H-16
Valve size 16 (D07)
Max. flow l/min (GPM) 300 (80)
Max. operating pressure at port P, A, B
bar (PSI)
350 (5080) 420 (6090)
- at port T (external drain) 210 (3050) 350 (5080)
- at port T (internal drain) 210 (3050)
Minimum pilot pressure bar (PSI) 12 (174)
Maximum pilot pressure bar (PSI) 210 (3050)* 350 (5080)*
Fluid temperature range (NBR) °C (°F) -30 ... +80 (-22 ... +176)
Fluid temperature range (FPM) °C (°F) -20 ... +80 (-4 ... +176)
Ambient temperature range °C (°F) -30 ... +50 (-22 ... +122)
Supply voltage tolerance % AC: ±10 DC: ±10
Max. switching frequency 1/h 10 000
Enclosure type acc.to EN 60529 IP 65
Switching time
at ν=32 mm
2
/s (156 SUS)
ON
ms
AC: 60 ... 80** DC: 50 ... 70**
OFF AC: 60 ... 80** DC: 60 ... 80**
Weight
RNH5-16
kg (lbs)
6.6 (14.6)
RNEH5-162 8.2 (18.1)
RNEH5-163 8.8 (19.4)
Data Sheet Type
General information GI_0060 Products and operating conditions
Mounting interface SMT_0019 Size 16
Spare parts SP_8010
* For higher system pressure use option „Z“
** The values indicated refer to a solenoid valve working with a pilot pressure of 100 bar (mineral
oil, temperature = 50°C, viscosity = 36 mm
2
/s, P - A and B - T connected). The energizing and
de-energizing times are obtained at the pressure variation which occurs on the lines.
Ports P, A, B, T max 17.5 mm (0.69 in)
Operating limits for maximum hydraulic power at rated
temperature and supplied with voltage equal
to 90% of the nominal value
The curve refers to the pressure
drop (body part only)
with back pressure valve
energized to which the pressure
drop of the reference spool
must be added.
Operating pressure p [bar (PSI)]
Flow Q [l/min (GPM)]
Pressure drop Δp [bar (PSI)]
Flow Q [l/min (GPM)]
Flow Q [l/min (GPM)]
Back pressure valve incorporated on line P
(type C3)
Pressures bar (PSI)
RNEH5 RNEH5H RNH5 RNH5H
Min. Max.
Pressure in P, A, B
ports
-
350
(5100)
420
(6090)
350
(5100)
420
(6090)
Piloting pressure
(X port and / or Y
port)
12
(175)
210
(3050)
350
(5100)
210
(3050)
350
(5100)
Pressure in T line
with internal drainage
-
210
(3050)
210
(3050)
- -
Pressure in T line
with external drainage
-
210
(3050)
350
(5100)
210
(3050)
350
(5100)
Pressure drop Δp [bar (PSI)]
Spool position P-A P-B A-T B-T P-T
Curves on graph
Z11 Energized 1 1 3 4
H11
Energized 1 1 4 4
De-energized 2
Y11
Energized 1 1 4 4
De-energized 4 4
C11
Energized 2 2 4 5
De-energized 4
R11, R21 1 1 3 4
X11, X21 1 1 4 4
J15, J19 1 1 3 4
2 - C11
1 - all other spools
RN -16 / / / -
EH
H
2
3
E1
E2
E5
5
5H
01200
02400
12060
23050
J19
J15
Z22
C11
R21
Y11
R11
H11
X21
X11
Z11
Z21
Subject to change · RNEH5-16_4023_2en_04/2019
www.argo-hytos.com
Page 2
Spool Symbols
Ordering Code
4/2 and 4/3 directional
control valve,
internally and externally
pilot operated
Spool symbols
see the table „Spool Symbols“
Design series
standard 350 bar
high pressure 420 bar
(not available for C11 spools)
Control Options
without additional features
main spool stroke limiter
main spool shifting speed control
shifting speed control, with orifice (0.8 mm)
in port P of solenoid pilot valve
Actuation
electrohydraulic
hydraulic
Valve size
ISO 4401-07-07-0-05 (CETOP 07)
Number of valve positions
two positions
three positions
Piloting
internal
internal with installed pressure reducing valve,
fixed 30 bar setting
external
No designation
Z
E
No designation
C
D
PF
No designation
I
Drain
external,
recommended when the valve is used with back pressure on the outlet
internal
No designation
C3
Check valve incorporated in P-line
if not required
with back pressure check valve
Rated supply voltage of solenoids
(at the coil terminal)
12 V DC / 2.72 A
24 V DC / 1.29 A
120 V AC / 0.35 A / 50 (60) Hz
230 V AC / 0.17 A / 50 (60) Hz
Solenoid electrical terminals
EN 175301-803-A
E1 with quenching diode
EN 175301-803-A with integrated rectifier
No designation
N1
N2
Manual override (only for RNEH)
standard
protected with retaining nut
protected with rubber boot
No designation
V
Seals
NBR
FPM (Viton)
No designation
B
Surface treatment
standard
zinc-coated (ZnNi), ISO 9227 (520 h)
Installation Note:
- It is necessary to ensure minimum pilot pressure , therefore either external piloting or option C3 (check valve in P port) must be used for spools
which have connection between P and T ports (C11, H11, X21, R21, J19).
- Attention: spools J15, J19 may assume an undefined position without energy supply.
- For directional valves with two solenoids, one solenoid must be de-energized before the other solenoid can be energized.
- The AC coils correspond to E5 solenoid electrical terminal.
- For other solenoid voltages see data sheet HA 8007.
- The solenoid operated valves are delivered without connectors. For connectors see data sheet HA 8008.
- Configurations with centering and recall springs can be mounted in any position; J15, J19 valves - without springs or mechanical
retention - must be mounted with the longitudinal axis in the horizontal.
- Other special versions are available. Consult our technical department.
Three positions with centering spring Two positions with return spring
Two positions with mechanical detent on pilot valve
Symbols are referred to the solenoid valve RNEH. For the hydraulic control version RNH
please see the connection schematic (see page 3)
see data sheet RPE3-06 (4010) for other pilot valve options
17 (0.67)
C3
TP
b
a
AB
Y
In the C3 version the piloting is always internal.
The back pressure valve can’t be used as a check
valve because it doesn’t guarantee sealing.
Subject to change · RNEH5-16_4023_2en_04/2019
www.argo-hytos.com
Page 3
Pilot and Drain
Electrical Features
Actuation in millimeters (inches)
RNH5-162R RNH5-162X RNH5-163
Check Valve Incorporated in Line P
Check valve incorporated in line P: C3
Valves RNEH are available with an incorporated back pressure valve
on line P (Type „C3“). This is necessary to obtain the piloting pressure when the control valve
(in the rest position) has the line P connected to the port T (spools H11, C11, X21, R21, J19).
The cracking pressure is 5 bar with a minimum flow rate of 15 l/min.
Solenoid control: RNEH
The valve is supplied with an RPE3-06 pilot solenoid valve.
Hydraulic control: RNH
The valve is supplied with a cross-connection cover plate.
X and Y connections are used for the hydraulic control of the valve.
The RNEH valves are available with pilot and drain, both internal and external. The version with external drain allows for a higher back pressure on the outlet.
Type of valve
Plug assembly
X Y
RNEH5-16**/*** internal pilot and external drain NO YES
RNEH5-16**/**I internal pilot and internal drain NO NO
RNEH5-16**/*E* external pilot and external drain YES YES
RNEH5-16**/*EI external pilot and internal drain YES NO
plug M6x8
X: for external pilot, Y: for external drain
The back pressure valve can be also delivered separately and it can be easily mounted on line P
of the main control valve. Specify the code to order the back pressure valve separately from the spare
part data sheet No. 8010.
pilot always internal
Y: plug M6x8 for external drain
Solenoids
The operating solenoids are DC solenoids. For AC supply, the solenoids are provided with a rectifier integrated in the DIN connector socket
as part of the solenoid. The connectors can be turned by 90°. By loosening the nut, the solenoids can be turned or replaced without interfering
with any seals of the valve. In case of a solenoid malfunction or power failure, the spool of the valve can be shifted by manual override, provided
the pressure in port T does not exceed 25 bar.
For detail information on the pilot valve RPE3-06 refer to data sheet No. 4010.
The minimum piloting pressure can be as low as 5 bar at low flow rates, but with higher flow rates a pressure of 12 bar is needed.
If the valve operates with higher pressures it is necessary to use the version with external pilot and reduced pilot pressure.
Otherwise, the valve with internal pilot and a pressure reducing valve with a 30 bar fixed setting can be ordered.
Valve 2VS3-06
(or reducing valve)
Subject to change · RNEH5-16_4023_2en_04/2019
www.argo-hytos.com
Page 4
Control Options - Special Features
Control of the main spool shifting speed: D
By placing a 2VS3-06 flow control valve between
the pilot solenoid valve and the hydropiloted valve, the pilot flow
rate can be controlled and therefore the shifting speed adjusted.
Add the letter D to the identification code to request this device.
Pilot pressure reducing valve - 30 bar fixed setting: Z
Internal piloting with mounted pressure reducing valve
with 30 bar fixed setting. The option Z may be used together
with option D.
RNEH5-162, RNEH5-163
*bolts not supplied
Control of the main spool stroke: C
Using special side plugs, it is possible to introduce stroke control the piloted
valve so as to vary the maximum spool opening clearance. This solution allows
the control of the flow rate from the pump to the actuator and from
the actuator to the outlet, resulting in double adjustable control of the actuator.
Add the letter C to the identification code to request this device.
Shifting speed control: PF
with an orifice (0.8 mm) in port P of the solenoid pilot valve
Add PF to the identification code to request this device
mounting hole threads: M6x12 (1/2-13 UNC)
M10x20 (1/2-13 UNC)
57 Nm
(42 lbf.ft)
4x M10x60*
(bolts A10.9)
12 Nm
(8.9 lbf.ft)
2x M6x50*
Space required
to remove coil
Space required to remove
connector
Dimensions in millimeters (inches)
Solenoid operated distributor with pilot valve in the configuration 3H11
It is possible to deliver the solenoid operated distributor with the pilot valve in configuration
3H11 (all the ports at the outlet). This configuration is used with external piloting in order
to allow the unloading of the piloting line when the solenoid operated valve is in the rest
position. With this option, the piloting is necessarily external.