Page 315
www.argo-hytos.com
HD 319 · HD 419 · HD 619
In-line mounting · Operating pressure up to 630 bar / 9137 psi · Nominal fl ow rate up to 450 l/min / 118.9 gpm
High Pressure Filters - Worldline 300
Description
Application
In the high pressure circuits of hydraulic systems.
Performance features
Protection against wear:
By means of fi lter elements that even in full-fl ow fi ltration meet
the highest demands regarding cleanliness classes.
Protection against malfunction:
Through installation near to the control valves or other expensive
components. The specifi c determined fl ow rate guarantees a
closed by-pass valve even at ν 200 mm
2
/s / 927 SUS (cold start
condition).
Filter elements
Flow direction from outside to center.
The star-shaped pleating of the fi lter material results in:
large fi lter surfaces
low pressure drop
high dirt-holding capacities
long service life
Filter maintenance
By using a clogging indicator the correct moment for main-
tenance is stated and guarantees the optimum utilization of the
lter life.
Materials
Filter head: Spheroidal graphite cast iron (SGI)
Filter bowl: Cold extruded steel
Coating: Powder paint
Seals: NBR (FPM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer
microfi ber web
Accessories
Electrical and / or optical clogging indicators are available on
request. Dimensions and technical data see catalog sheet 60.40.
High Pressure Filter HD 319
Subject to change· 40.70-EN/US · 1218
Page 316
www.argo-hytos.com
Characteristics
Operating pressure
0 ... 360 bar / 5220 psi, min. 2 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 630 bar / 9137 psi, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Nominal flow rate
Up to 450 l/min / 118.9 gpm (see Selection Charts, column 2).
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
closed by-pass valve at ν 200 mm
2
/s / 927 SUS
element service life > 1000 operating hours at an average
fluid contamination of 0.07 g per l/min / 0.27 g per gpm
flow volume
flow velocity in the connection lines:
up to 250 bar 8 m/s / up to 3626 psi 26.3 ft/s
> 250 bar 12 m/s / > 3626 psi 39.4 ft/s
Filter fineness
5 µm(c) ... 16 µm(c)
β-values according to ISO 16889
(see Selection Charts, column 4 and diagram Dx).
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Charts, column 5).
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20).
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
-22 °F ... +212 °F (temporary -40 °F ... +248 °F)
Viscosity at nominal flow rate
at operating temperature: ν < 60 mm
2
/s / 280 SUS
as starting viscosity: ν
max
= 1200 mm
2
/s / 5560 SUS
at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70% p of the cracking pressure
of the by-pass valve on the vertical axis. Draw a horizontal line
so that it intersects the p curve at a point. Read this point on
the horizontal axis for the viscosity.
Mounting position
Preferably vertical, filter head on top.
Connection
Threaded ports according to
ISO 228 or DIN 13
SAE standard J514
SAE-flange (6000 psi)
Sizes see Order Information and Selection Charts, column 6
as well as ordering example (other connections on request).
8702
7252
5802
Operating pressure p [bar] [psi]
Number of cycles n
Subject to change · 40.70-EN/US · 1218
Page 317
www.argo-hytos.com
Diagrams
D1
Pressure drop as a function of the flow volume
at ν = 35 mm
2
/s / 162 SUS (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
1,0
0,5
1,5
HD 319
1
2
4+5
6
0
3
100 200 300 400 500
0
2
4
6
8
10
12
1+3
2
5
4
6
200 400 600
800
1000
ν [mm
2
/s]
ν [SUS]
Q [l/min]
p [bar]
p [psi]
p [bar]
p [psi]
Q [gpm]
p-curves for complete filters in Selection Charts, column 3
D2
Pressure drop as a function of the flow volume
at ν = 35 mm
2
/s / 162 SUS (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
1,0
0,5
1,5
HD 419
1
2
4+5
6
0
3
100 200 300 400 500
0
2
4
6
8
10
12
1+3
2
6
5
4
4
6
200 400 600
800
1000
ν [mm
2
/s]
ν [SUS]
Q [l/min]
p [bar]
p [psi]
p [bar]
p [psi]
Q [gpm]
D3
Pressure drop as a function of the flow volume
at ν = 35 mm
2
/s / 162 SUS (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
1,0
0,5
1,5
HD 619
1
2
4+5
6
0
3
100 200 300 400 500
0
2
4
6
8
10
12
1
3+5
2
6
4
6
200 400 600
800
1000
ν [mm
2
/s]
ν [SUS]
Q [l/min]
p [bar]
p [psi]
p [bar]
p [psi]
Q [gpm]
Subject to change· 40.70-EN/US · 1218
0 927 1854 2781 3708 4635
21.8
14.5
7.3
0
0 26 53 79 106 132
174
145
116
87
58
29
0
0 927 1854 2781 3708 4635
21.8
14.5
7.3
0
0 26 53 79 106 132
174
145
116
87
58
29
0
0 927 1854 2781 3708 4635
21.8
14.5
7.3
0
0 26 53 79 106 132
174
145
116
87
58
29
0
1.5
1.0
0.5
1.5
1.0
0.5
1.5
1.0
0.5
Page 318
www.argo-hytos.com
Dx
Filter fineness curves in Selection Charts, column 4
Filtration ratio β as a function of particle size x obtained
by the Multi-Pass Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For screen elements:
40S = screen material with mesh size 40 µm
60S = screen material with mesh size 60 µm
100S = screen material with mesh size 100 µm
Tolerances for mesh size according to DIN 4189
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Filtration ratio β for particlesl > x µm
Particle size x [µm] (for particles larger
than the given particle size x)
Efficiency [%]
Subject to change · 40.70-EN/US · 1218
Order Information
Two different head pieces with four various connecting options are available.
Order example: The filter HD 319-265 has to be supplied with SAE 1¼ flanged connection (with metric fastening
threads) and with an optical clogging indicator with automatic reset.
Order description: HD 319-165 OD1
Connections:
4 options are available
Flanged connection (A/B) SAE 1¼ (6000 psi)
1
1
Threaded port (A/B) G1¼ resp. G1½
2
2
Flanged connection (A/B) SAE 1¼ (6000 psi)
3
3
Threaded port (A/B) -20 SAE resp. -24 SAE
4
7
Clogging indicator (code)
For the appropriate clogging indicator see catalog sheet 60.40. The desired clogging indicator model is indicated by the code
(Selection Charts, column 2).
1
With metric fastening threads
2
G1½ from size HD 619 upwards
3
With UNC fastening threads
4
-24 SAE (1
7
/
8
-12 UN-2B) from size HD 619 upwards
Page 319
www.argo-hytos.com
Selection Chart 1 of 2
Part No.
1
Nominal flow rate
Pressure drop see
diagram D/curve no.
Filter fineness see diagr. Dx
Dirt-holding capactiy
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Cracking pressure in ( )
Remarks /
contact type of
clogging
indicator
Subject to change· 40.70-EN/US · 1218
l/min g bar kg bar
1 2 3 4 5 6 7 8 9 10 11 12
HD 319-289 ED8 110 D1/1 5EX2 20 G1¼ - 4 V3.0817-13
3
16.3 electrical (5) change-over
HD 319-269 155 D1/2 5EX2 24 G1¼ 7 1 V3.0817-03 15.9 - -
HD 319-286 ED8 195 D1/3 10EX2 24 G1¼ - 4 V3.0817-16
3
16.3 electrical (5) change-over
HD 319-265
2
250 D1/4 10EX2 33 G1¼ 7 1 V3.0817-06 15.9 - -
HD 319-288 ED8 270 D1/5 16EX2 25 G1¼ - 4 V3.0817-18
3
16.3 electrical (5) change-over
HD 319-267
2
330 D1/6 16EX2 33 G1¼ 7 1 V3.0817-08 15.9 - -
HD 419-289 ED8 155 D2/1 5EX2 29 G1¼ - 4 V3.0823-13
3
17.8 electrical (5) change-over
HD 419-269 190 D2/2 5EX2 33 G1¼ 7 1 V3.0823-03 17.2 - -
HD 419-286 ED8 265 D2/3 10EX2 33 G1¼ - 4 V3.0823-16
3
17.8 electrical (5) change-over
HD 419-266
2
330 D2/4 10EX2 47 G1¼ 7 1 V3.0823-06 17.2 - -
HD 419-288 ED8 330 D2/5 16EX2 35 G1¼ - 4 V3.0823-18
3
17.8 electrical (5) change-over
HD 419-268
2
380 D2/6 16EX2 48 G1¼ 7 1 V3.0823-08 17.2 - -
HD 619-289 ED8 220 D3/1 5EX2 41 G1½ - 4 V3.0833-13
3
20.6 electrical (5) change-over
HD 619-269 280 D3/2 5EX2 49 G1½ 7 1 V3.0833-03 19.9 - -
HD 619-286 ED8 330 D3/3 10EX2 49 G1½ - 4 V3.0833-16
3
20.6 electrical (5) change-over
HD 619-266
2
400 D3/4 10EX2 67 G1½ 7 1 V3.0833-06 19.9 - -
HD 619-288 ED8 450 D3/5 16EX2 51 G1½ - 4 V3.0833-18
3
20.6 electrical (5) change-over
HD 619-268
2
450 D3/6 16EX2 68 G1½ 7 1 V3.0833-08 19.9 - -
1
For additional options please see section “Order Information“
2
Preferred type, no minimum order quantity required
3
Element differential pressure stable up to 160 bar, clogging indicator required
Optical or electrical clogging indicators are available to monitor the clogging condition of the element. When ordering filters with
integrated monitoring, the code of the clogging indicator (to be found in catalog sheet 60.40) has to be added to the part no. of the
desired filter (basic unit).
The mounting hole for clogging indicators is available at all filters, i.e. all clogging indicators from catalog sheet 60.40 can also be
retroffited.
For the appropriate clogging indicator see catalog sheet 60.40.
Oder example: see “Order Information“.
Remarks:
The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
For versions with electrical clogging indicator, the device socket is not included in the scope of delivery.
For the electrical clogging indicator of type ED8, a transparent socket with two LEDs is available, which additionally enables visual
indication of the filter contamination (order no. DG 041.1200).
The filters listed in this chart are standard filters. Other designs available on request.
Page 320
www.argo-hytos.com
Selection Chart 2 of 2
Part No.
1
Nominal flow rate
Pressure drop see
diagram D/curve no.
Filter fineness see diagr. Dx
Dirt-holding capactiy
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Cracking pressure in ( )
Remarks /
contact type of
clogging
indicator
Subject to change · 40.70-EN/US · 1218
gpm g psi lbs psi
1 2 3 4 5 6 7 8 9 10 11 12
HD 319-789 ED8 29.1 D1/1 5EX2 20 -20
4
- 4 V3.0817-13
3
35.9 electrical (73) change-over
HD 319-769 40.9 D1/2 5EX2 24 -20
4
102 1 V3.0817-03 35.1 - -
HD 319-786 ED8 51.5 D1/3 10EX2 24 -20
4
- 4 V3.0817-16
3
35.9 electrical (73) change-over
HD 319-766
2
66.0 D1/4 10EX2 33 -20
4
102 1 V3.0817-06 35.1 - -
HD 319-788 ED8 71.3 D1/5 16EX2 25 -20
4
- 4 V3.0817-18
3
35.9 electrical (73) change-over
HD 319-768
2
87.2 D1/6 16EX2 33 -20
4
102 1 V3.0817-08 35.1 - -
HD 419-789 ED8 40.9 D2/1 5EX2 29 -20
4
- 4 V3.0823-13
3
39.2 electrical (73) change-over
HD 419-769 50.2 D2/2 5EX2 33 -20
4
102 1 V3.0823-03 37.9 - -
HD 419-786 ED8 70.0 D2/3 10EX2 33 -20
4
- 4 V3.0823-16
3
39.2 electrical (73) change-over
HD 419-766
2
87.2 D2/4 10EX2 47 -20
4
102 1 V3.0823-06 37.9 - -
HD 419-788 ED8 87.2 D2/5 16EX2 35 -20
4
- 4 V3.0823-18
3
39.2 electrical (73) change-over
HD 419-768
2
100.4 D2/6 16EX2 48 -20
4
102 1 V3.0823-08 37.9 - -
HD 619-789 ED8 58.1 D3/1 5EX2 41 -24
5
- 4 V3.0833-13
3
45.4 electrical (73) change-over
HD 619-769 73.9 D3/2 5EX2 49 -24
5
102 1 V3.0833-03 43.9 - -
HD 619-786 ED8 87.2 D3/3 10EX2 49 -24
5
- 4 V3.0833-16
3
45.4 electrical (73) change-over
HD 619-766
2
105.6 D3/4 10EX2 67 -24
5
102 1 V3.0833-06 43.9 - -
HD 619-788 ED8 118.9 D3/5 16EX2 51 -24
5
- 4 V3.0833-18
3
45.4 electrical (73) change-over
HD 619-768
2
118.9 D3/6 16EX2 68 -24
5
102 1 V3.0833-08 43.9 - -
1
For additional options please see section “Order Information“
2
Preferred type, no minimum order quantity required
3
Element differential pressure stable up to 2320 psi, clogging indicator required
4
Corresponds to 1
5
/
8
-12 UN-2B
5
Corresponds to 1
7
/
8
-12 UN-2B
Optical or electrical clogging indicators are available to monitor the clogging condition of the element. When ordering filters with
integrated monitoring, the code of the clogging indicator (to be found in catalog sheet 60.40) has to be added to the part no. of the
desired filter (basic unit).
The mounting hole for clogging indicators is available at all filters, i.e. all clogging indicators from catalog sheet 60.40 can also be
retroffited.
For the appropriate clogging indicator see catalog sheet 60.40.
Oder example: see “Order Information“.
Remarks:
The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
For versions with electrical clogging indicator, the device socket is not included in the scope of delivery.
For the electrical clogging indicator of type ED8, a transparent socket with two LEDs is available, which additionally enables visual
indication of the filter contamination (order no. DG 041.1200).
The filters listed in this chart are standard filters. Other designs available on request.
Page 321
www.argo-hytos.com
C1
E1
F
DI
C1
G
H
G
F
DI E2
X
H
R
K
L
C2
Q
N
M
S
Z
Y
V
T
W
P
U
O
HD 319
Katalogblatt 40.70
3
2
1
A
B
A
B
Dimensions
Measurements in mm
Measurements in inch
2
½-13 UNG-2B / 0.78
3
W
Flange
= ½-13 UNC-2B, W
Thread
=
7
/
16
-14 UNC-2B, depth = 0.71
Subject to change· 40.70-EN/US · 1218
Type A/B C
1
C
2
D E
1
E
2
F G H I K L M
Ø / depth
N
HD 319 see 65 31 259 45 52 86 145 109 55 AF 32 66,7 M14 / 22 31.8
HD 419 Selection 65 31 323 45 52 86 145 109 55 AF 32 66,7 M14 / 22 31.8
HD 619 Chart 65 31 424 45 52 86 145 109 55 AF 32 66,7 M14 / 22 31.8
Type O P Q R
S
T U V W
Ø / depth
X
Y
Z
HD 319 18.5 33 81 152 AF 24 148 8 80 M12 / 18 24
30
100
HD 419 18.5 33 81 152 AF 24 148 8 80 M12 / 18 24
30
100
HD 619 18.5 33 81 152 AF 24 148 8 80 M12 / 18 24
30
100
Type A/B C
1
C
2
D E
1
E
2
F G H I K
mm
L M
Ø / depth
N
HD 319 see 2.56 1.22 10.20 1.77 2.05 3.39 5.71 4.29 2.17 AF 32 2.63
2
1.25
HD 419 Selection 2.56 1.22 12.72 1.77 2.05 3.39 5.71 4.29 2.17 AF 32 2.63
2
1.25
HD 619 Chart 2.56 1.22 16.69 1.77 2.05 3.39 5.71 4.19 2.17 AF 32 2.63
2
1.25
Type O P Q R S
mm
T U V W
Ø / depth
X Y
mm
Z
HD 319 0.73 1.30 3.19 5.98 AF 24 5.83 0.31 3.15
3
0.94
1.18
3.86
HD 419 0.73 1.30 3.19 5.98 AF 24 5.83 0.31 3.15
3
0.94
1.18
3.86
HD 619 0.73 1.30 3.19 5.98 AF 24 5.83 0.31 3.15
3
0.94
1.18
3.86
Flanged connection
Version with
integrated
optical clogging
indicator OD1
Version with integrated
electrical clogging
indicator ED8
and connector socket
1
Minimum
distance from
ferromagnetic
parts:
7 mm / 0.3 inch
Terminal connection ED8
1
not included in scope of delivery
Threaded connection
Page 322
www.argo-hytos.com
Spare Parts
Pos. Designation Part No.
1 Filter bowl HD 319
(with Pos. 2 und 3)
HD 250.0701
1 Filter bowl HD 419
(with Pos. 2 und 3)
HD 451.0702
1 Filter bowl HD 619
(with Pos. 2 und 3)
HD 619.0701
2 Back-ring HD 255.0102
3 O-ring
94.84 x 3.53 mm
3.73 x 0.14 inch
N007.0953
4 Replacement filter element see Chart / col. 9
5 Clogging indicator see catalog sheet 60.40
The functions of the complete filters as well as the outstanding
features of the filter elements assured by ARGO-HYTOS can
only be guaranteed if original ARGO-HYTOS spare parts are
used.
Quality Assurance
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to
the following ISO standards:
ISO 2941 Verification of collapse / burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high viscosity fluid
Before release into the series production the filter casing is tested for fatigue strength in our pressure pulse test rig.
Various quality controls during the production process guarantee the leakfree function and solidity of our filters.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.
Symbols
Subject to change · 40.70-EN/US · 1218
1 32
4
HD 319
Katalogblatt 40.70
2
4
1
5
3