Technical data
Subject to change
100.25-1us · 0714
We produce fluid power solutions
ARGO-HYTOS Inc. · P.O. Box 28 · Bowling Green, OH 43402 · USA
Tel: +1-419-353-6070 · Fax: +1-419-354-3496 · info.us@argo-hytos.com · www.argo-hytos.com
Pressure range (relative pressure) PSC 010-1713 PSC 100-1843 PSC 250-1843 PSC 400-1843
Measuring range psi 145 1,450 3,625 5,800
Overload pressure psi 290 2,900 5.440 8,700
Burst pressure psi 435 4,350 7,250 11,600
Service life 10 mio. pressure cycles
Output signal - options 4 … 20 mA
Auxiliary power UB VDC 8-30
Current consumption mA signal current (max. 20) for current output
Insulation voltage VDC 500
Total error in the
nominal temperature range
% ≤ 1,0 % of margin
Response time ms ≤ 2 ms, max. to 63 % of full scale pressure with step change on input
Accuracy % ≤ 0,5 % of margin
Nonlinearity % ≤ 0,1 % of margin
1-year stability % ≤ 0,2 % of margin
Pressure connection G1/4"A DIN 3852-E
Electrical connection (plug) / IP
protection classes
M12 - 4 POLE IP 67
Weight g approx. 80
Materials in contact with
measured medium
Pressure connnection / housing 1.4301
Sensor measuring cell 1.4542 or comparable
Permitted temperature ranges
Media temperature °F -22 °F to +230 °F
Ambient temperature range °F -22 °F to +212 °F*
Storage temperature range °F -22 °F to +212 °F*
*Limited temperature range with
M12 connection plug
°F +5 °F to +185 °F
Nominal temperature range °F +32 °F to +176 °F
Vibration resistance g
PSD
20 according to IEC 60068-2-6 (Vibration under resonance)
20 according to IEC 60068-2-64 (noises)
EMV tests EN 61000-4-1 to -6
EN 61000-6-4
CE conformity
EMV Directive 2004/108/EG noise emission und interference resistance
Pressure Equipment Directive Classification according to Pressure Equipment Directive 97/23/EG as pressure maintaining
components with safety function (article 3. sect. 3).
RoHs conformity Yes