34 Return to Table of Contents V20.1
Adjustable stroke-limiting cover for decreasing the traveling distance of logic valve
Set screws for locking
A solenoid or B solenoid options
Ships standard with an orifice installed in the P port & B plugged
Removable orifice plug options
Applications
Directional / Flow control valve
By connecting the X port to the B
port (side of logic insert) &
connecting the Y port to drain, you
can create a directional valve with
flow control. Plug option 1 will
allow the valve to dump in the
energized state. Plug option 2 will
allow the valve to dump in the de-
energized state.
DIN 24342 COVER FOR FLOW
CONTROL
SIZES 25mm TO 80mm
5000 PSI
Left: Standard plug
option
Right: Plug option #2
35 Return to Table of Contents V20.1
General Layout
Sizes 25mm to 63mm (80mm with D05 interface not shown)
Cover
Size
B
Threads in X,
Z1, Z2, & Y
*Orifice in P
Bolts
Threads
25 mm
2.50”
1/16-27 NPT
1/4-20 UNC
1/2-13 X 3.00" (4)
32 mm
3.25”
1/16-27 NPT
1/16-27 NPT
5/8-11 X 3.25" (4)
40 mm
2.40”
1/16-27 NPT
1/16-27 NPT
3/4-10 X 2.50" (4)
50 mm
2.75”
1/16-27 NPT
1/16-27 NPT
3/4-10 X 3.00" (4)
63 mm
3.50”
1/16-27 NPT
1/16-27 NPT
1-1/4-7 X 3.50" (4)
80 mm
4.00”
1/8-27 NPT
1/8-27 NPT
1-8 X 5.00" (8)
*Only one orifice installed in P port of D03 interface. Other orifices are optional.
Order Code
AMT-PSTK-**-D03-**-**
BL= Include bolts at extra
charge
Blank= Customer will supply
bolts
Size: 25, 32, 40, 50, 63, or 80mm
Poppet Stroke
Cover
Custom Orifice Size in
“mm” if other than
Standard Size
Examples: 08 = 0.8 mm
10 = 1.0 mm
12 = 1.2 mm
Almo
Manifold
& Tool