38 Return to Table of Contents V20.1
Adjustable stroke-limiting cover for decreasing the traveling distance of logic valve
Stroke adjustment under SAE plug for tamper resistance & protection from elements
Jam Nut for locking
SAE O-ring port for gauging & access to orifice
Applications
Check/Flow Control Valve
Provides metered-flow from A to B & check function
from B to A by connecting the X pilot to the B port of
the logic valve.
NOTE: To eliminate the check valve function & only
use the metering capabilities, connect the X
pilot to a drain line instead of connecting the X pilot
to the B port.
DIN 24342 COVER FOR FLOW
CONTROL
SIZES 25mm TO 63mm
5000 PSI
39 Return to Table of Contents V20.1
General Layout
Sizes 25mm to 63mm
Cover
Size
A
B
*Orifice in X SAE Port
Bolts
Threads
Size
25 mm
3.50"
5.00"
1/16-27 NPT
1.2 mm
1/2-13 X 5.00" (4)
32 mm
4.00"
5.00"
1/16-27 NPT
1.3 mm
5/8-11 X 5.00" (4)
40 mm
5.00"
7.00"
1/16-27 NPT
1.5 mm
3/4-10 X 6.00" (4)
50 mm
5.55"
7.00"
1/16-27 NPT
1.8 mm
3/4-10 X 6.00" (4)
63 mm
7.00"
7.00"
1/8-27 NPT
2.0 mm
1-1/4-7 X 7.00" (4)
*Only one orifice installed in X SAE port. Other orifices are optional.
Order Code
AMT-PSLSH-**-**-**
Size: 25, 32, 40, 50, or 63mm
Custom Orifice Size in
“mm” if other than
Standard Size
Examples: 08 = 0.8 mm
10 = 1.0 mm
12 = 1.2 mm
Almo
Manifold
& Tool
BL= Include bolts at extra
charge
Blank= Customer will supply
bolts
Poppet Stroke
Limiter Hidden